• Title/Summary/Keyword: 설치높이

Search Result 891, Processing Time 0.042 seconds

Design of lift-down kitchen cabinet for elderly and disabled (고령자 및 장애인을 위한 승강형 주방 상부장 설계)

  • Kibum Shim;Hoon Shim;Geon-Hyeok Lim;Jiwon Jang;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.465-470
    • /
    • 2024
  • Kitchen cabinets are widely used for their spacious storage and efficient use of space, but their high installed location makes it difficult for the elderly and disabled to access. Therefore, in this paper, we propose a new height-adjustable kitchen cabinet that can be used more easily and safely. The lift-down range of cabinet was set considering the installation location of cabinet for efficient use of kitchen space and the maximum height accessible to the elderly and disabled, and the link geometry and driving method of the complex link mechanism were determined through the mechanism design procedure to ensure that the selected floor come down safely along the optimal descend path. In addition, the appropriate motor and control algorithm were added to allow the user to descend to the desired height with a simple button operation. It was confirmed through actual production that the proposed linkage mechanism performs the desired lift-down motion.

아파트 베란다 난간대 강도 실험

  • 오태호;손기상;김수건
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.208-212
    • /
    • 2002
  • 난간대가 사용되는 곳은 건설현장, 건물 외에도 제조현장, 제조공장 등 사람이 가는 곳, 작업자가 통과하는 곳에는 어디서나 존재한다고 보면 될 것이다. 산업안전보건법의 안전기준 제27조에서는 사업주는 4단 이상의 계단에 개방된 측면에는 난간을 설치하고 다음 각 호의 조치를 하여야 한다 1) 난간의 높이는 90cm 이상이 되도록 할 것 2) 난간은 계단참을 포함하여 각 층의 계단 전체에 걸쳐서 설치 할 것. 3) 목재로 된 난간은 5제곱cm 이상의 단면을 금속제 파이프로 된 난간을 4cm 이상의 지름을 갖는 것일 것. 4) 난간은 임의의 점에 있어서 임의의 방향으로 움직이는 100kg 이상의 하중에 견딜 수 있는 튼튼한 구조로 할 것 5) 난간의 지주는 2m 이내마다 설치하고 가능한 한 단면과 난간 상면과의 중앙부에 중간대를 설치할 것으로 규정하고 있다. 상기 사항에서 3)항은 구조적으로 중요한 요소로서 외부하중에 대한 내력상의 문제가 있을 것으로 판단되어 이에 대한 실험규명이 필요하게 되었고 본 연구의 목적이 되었다.

  • PDF

A Study on Diagnosis System Development of Overhead Transmission Lines (송전선로 이상진단 시스템 개발에 관한 연구)

  • Oh, Yong-Cheul;Kim, Tag-Yong;Lee, Dong-Kyu;Chung, Han-Seok;Kim, Chung-Hyeok;Lee, Deok-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1539-1540
    • /
    • 2015
  • 본 연구는 가공 활선 송전선로의 이상 진단을 위한 시스템 개발에 관한 것으로 송전 철탑 경간내에 설치되어 있는 송전선을 주행하며 전선의 내부 또는 외부의 열화를 확인하기 위한 것이다. 본 연구에 의한 시스템은 지상으로부터 30m 이상의 높이에서 설치되어 운행되기 때문에 바람에 의해 낙하되지 않도록 구성하였다. 또한 복도체 또는 4도체 선로를 주행하도록 설계하였으며 345kV 고압에서도 전계 및 자계의 영향을 받지 않도록 설계하였다. 전선의 이상 검지를 위해서 카메라를 설치하여 얻어진 데이터를 영상 처리 하여 이상 부위에 대한 에너지 변화를 관찰하여 이상 유무를 판단하도록 하였다. 완성된 시스템은 설치 및 이동을 위해서 경량화 시켰으며 분해 조립이 쉽도록 구성하였다. 본 시스템의 현장 적용에 의한 실험 결과 1m/sec의 이동 속도에서 1mm 이하의 스크래치에 대하여 검출이 가능하였다.

  • PDF

Mixing Effect of Decreased Volume in Mixture Pond by Partition (격벽에 의한 혼화지 부피 축소에 따른 혼화효과 분석)

  • Choi, Gye-Woon;Lee, Ho-Sun;Kim, Jung-Young;Lee, Joo-Kyong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1189-1193
    • /
    • 2007
  • 국내 정수장내 설치되어 있는 혼화기는 대부분 기계식 급속혼화 방식을 채택하여 운영하고 있으며 대부분의 혼화지가 크게 설계되어 설계 변경을 하지 않고서는 혼화 효율을 높이는 한계가 있다. 혼화지내 격벽을 설치하여 혼화 구간을 축소시킴으로써 혼화구간이 큰 구조에 비해 6.27%의 효율이 더 좋은 것으로 나타났으며 격벽이 설치된 혼화구간내에 임펠러는 격벽으로 둘러싸인 유출부쪽(상단부)에서 85.45%로 가장 좋은 효과가 나타났다. 또한 약품위치가 임펠러 하단에 가까우면 혼화효과가 크며 멀 경우에 격벽설치에 따른 혼화효과가 더욱 큰 것으로 나타났다.

  • PDF

Experimental Study on Bed Change Around Downward Vertical Groyne with Installed Spacing (설치간격에 따른 하향수제 하상변동에 관한 실험연구)

  • Yeo, Hong-Koo;Kang, Joon-Gu;Kim, Sung-Jung;Yoon, Byeong-Mo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.343-347
    • /
    • 2011
  • 하천 내 설치하는 수제는 제방보호 및 유로변경의 목적으로 하천내 시공되는 구조물 중의 하나로서 하천복원과정에 있어 필수불가결한 구조물 중의 하나로 인식되고 있다. 수제는 대개 하나 이상의 일련의 군집형태로 수로 자체의 특성을 고려하여 설치가 되고 있다. 그러나 이러한 수제의 무분별한 설치는 주변 경관을 저해하는 요소로 나타날 수 있을 뿐만 아니라 시공에 따른 비용에 적지 않은 부담을 야기 시키기 충분하다.본 실험에서는 하향수제($\theta=135^{\circ}$)를 대상으로 수제간격에 대한 이동상 실험을 수행하여 수제주변 및 수제역 내에서 발생하는 하상변동특성을 검토하고자 하였다. 실험은 폭 1.2m, 길이 50m, 높이 1.5m 인 직선수로에서 수로폭의 15%길이를 갖는 하향수제($\theta=135^{\circ}$) 2개를 대상으로 각각 수제길이의 2~ 8배의 간격 조절을 통해 하상변동실험을 수행 하였다. 실험용입자는 중간입경($d_{50}$)이 0.15mm 인 모래를 사용하였으며 6시간 동안 통수하였다. 실험 결과 수제의 간격이 4배 미만으로 설치되었을 때 전면부 수제에서 발생하는 세굴의 영향이 후면부 수제 설치지점에 연장되어 나타나는 것이 확인 되었으며 수제간격이 7배 일 경우 전면부 수제에서 발생하는 최대세굴과 같은 세굴심이 관측되었다. 또한 수제간격이 4배이상으로 설치될 경우 후면부 수제에서 독립적인 세굴이 발생하고 있었는데 이는 직각수제 세굴과 동일한 현상으로 나타났다.

  • PDF

Experimental Study on Bed Change Around Vertical Groyne with Installed Spacing (설치간격에 따른 연직수제주변 하상변동에 관한 실험연구)

  • Yeo, Hong-Koo;Kang, Joon-Gu;Kim, Sung-Jung;Yoon, Byeong-Mo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1745-1749
    • /
    • 2010
  • 하천 내 설치하는 수제는 제방보호 및 유로변경의 목적으로 하천내 시공되는 구조물 중의 하나로서 하천복원과정에 있어 필수불가결한 구조물 중의 하나로 인식되고 있다. 수제는 대개 하나 이상의 일련의 군집형태로 수로 자체의 특성을 고려하여 설치가 되고 있다. 그러나 이러한 수제의 무분별한 설치는 주변 경관을 저해하는 요소로 나타날 수 있을 뿐만 아니라 시공에 따른 비용에 적지 않은 부담을 야기 시키기 충분하다. 그러나 적절한 간격 조절을 통해 생태, 호안보호, 경관 등의 수제의 기능을 만족한다면 이보다 더 효율적인 것을 없을 것이다. 따라서 본 연구에서는 수제간격에 따른 하상변동 실험을 통해 효율적인 배치간격을 제시할 목적으로 수행되었다. 실험은 폭 1.2m, 길이 50m, 높이 1.5m 인 직선수로에서 수로폭의 15%길이를 갖는 연직수제를 2개를 대상으로 각각 수제길이의 2~8배의 간격 조절을 통해 하상변동실험을 수행 하였다. 실험용입자는 중간입경($d_{50}$)이 0.15mm 인 모래를 사용하였으며 6시간 동안 통수하였다. 실험결과 유수에 의해 첫 번째 설치된 수제에서 지배적으로 많은 영향을 받게 되면서 후면부에 설치된 수제는 비교적 영향을 덜 받고 있었다. 그러나 그 영향권을 점차 벗어나게 되면서 수제 간격이 4배 이상일 경우 후면부 수제에서도 세굴이 발생하고 있음을 확인할 수 있었다. 이러한 자료는 추후 수제설치에 따른 효율적인 배치 간격 결정에 중요한 자료로 이용될 수 있을 것이다. 그러나 수제들이 시공되는 대다수의 하천들은 어느 정도의 만곡도를 갖고 있기 때문에 이를 간과해서는 않될 것으로 판단된다.

  • PDF

A Riverbed Change Prediction by River-Crossing Structure -Focused on the Major River Reaches of the Multifunctional Administrative City- (하천 횡단구조물에 의한 하상변동 예측 - 행정중심복합도시 주요 하천구간을 중심으로 -)

  • Yeon, Kyu-Sung;Jeong, Sang-Man;Yun, Chan-Young;Lee, Joo-Heon;Shin, Kwang-Seob
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.107-113
    • /
    • 2009
  • This study has been conducted for the long-term riverbed change prediction on Geum River and Miho Stream surrounding the planned Multifunctional Administrative City and the neighboring regions by the construction of a small dam. Based on the analysis of vertical riverbed changes of the cross-sectional data for the years 1988, 2002 and 2007, minimum bed elevation significantly decreased in both Geum River and Miho Stream in 2007 as compared to 1988. Compared to 2002, however, a slight elevation change was observed. To make a long-term prediction on riverbed changes by the construction of a small dam, a one dimensional HEC-RAS 4.0 model has been used. By the fixed bed model test, the water levels were calibrated. By using the cross-sectional data of 1988 and 2002, verification was conducted under a movable bed model. According to the prediction of riverbed changes for each scenario with varying height of small dam, minor impact is expected around Miho Stream while major impact is expected around Geum River by 2017, as the small dam height increases. If the small dam is 7m-high, for example, it's been simulated that 1.59m deposition would be expected around the upper stream of Miho Stream Confluence while 1.98m scour would be expected around the downstream of the small dam.

Development of Operation Control and Warning System of Movable Weir for River Safety Management (안전한 하천관리를 위한 가동보 방류제어 및 경보 시스템 개발)

  • Kim, Phil Shik;Kwon, Hyung Joong;Lee, Jae Hyouk;Cho, Bum Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.558-558
    • /
    • 2015
  • 하천 시설물은 홍수시 혹은 비상시 운영할 수 있는 경보시스템이나 관리지침 등의 마련이 필수적임에도 불구하고, 현재까지 가동보 시설물에 대한 비상시 운영 메뉴얼 및 경보시스템이 구축되지 못한 실정이다. 4대강 살리기 사업이나 하천정비사업과 같은 대표적인 하천관련 사업에서 단순한 하천 이 치수 목적뿐만 아니라 소수력 발전, 친수공간조성 등의 다목적 활용을 위하여 가동보 설치 사업이 다수 수행되었으며, 현재 국내 하천에 약 1,200여개의 가동보가 설치 운영되고 있다. 이와 같이 다목적 활용을 위하여 가동보의 수요가 급증하는데 반해, 각 설치 현장 상황에 적합한 가동보 운영지침이나 비상경보시스템이 구축되지 못한 실정이며, 적절한 지침 없이 관행적인 가동보 방류로 인한 물놀이 안전사고나 인명피해가 속출하고 있는 실정이다. 2012년 11월에는 하천 제수변 공사를 위해 전주천에 설치한 가동보를 임시적으로 방류하였는데, 하류측의 안전을 확인하지 않고 관행적으로 가동보를 방류하였고, 경보시스템의 부재로 인하여 가동보 하류측 징검다리를 건너는 유치원생들이 급류에 휩쓸리는 사고가 발생하였고, 최근 2014년 5월에는 수원시에 위치한 원천저수지 여수로 둑에 설치된 가로 34m 높이 1.6m 크기의 가동보가 공기압축기의 오작동으로 인하여 보 높이가 낮아지면서 약 30분 원천저수지 하류의 원천리천에 갑자기 무리 불어나 산책로가 침수되고 인근에 산책하던 주민들이 휩쓸려 떠내려가는 사고가 발생하였다. 해외에서도 가동보 운영 미숙으로 인하여 인명사고가 발생하는데, 2008년 11월 호주에서는 하류측 상황 점검이나 경고 방송 없이 가동보를 도복시켜 4살 여아가 급류에 사망하는 사고가 발생하였다. 국외의 경우에는, 상류측 홍수 수위나 하류측 역류 수위를 조절하기 위하여 가동보의 높이를 제어하는 시스템을 구비하고 있지만 이러한 시스템 역시 단순한 수위조절 기능으로서 가동보의 방류량을 제어하지 못하는 실정이다. 가동보를 운영하기 위한 조작시스템은 국내의 경우, 조작실의 조작판넬을 이용하여 가동보의 기립/도복 조작이나 원격 조작 기능과 같은 단순기능만을 구비하고 있어 가동보 방류시 하류측의 범람 피해를 야기하고 있다. 본 연구에서는 가동보 방류에 의한 하류측 범람 피해를 최소화하기 위하여 (1) 가동보 도복에 의한 방류량 산정 알고리즘을 개발하고, (2) 방류량에 따른 하류측 수위상승 범위 예측 기법을 개발하고, (3) 가동보 도복 속도를 제어하는 방류량 제어시스템을 개발하고, (4) 가동보 방류에 의한 비상경보시스템을 개발하였다.

  • PDF

Development of Operation Control and Warning System of Movable Weir for River Safety Management (안전한 하천관리를 위한 가동보 방류제어 및 경보 시스템 개발)

  • Kim, Phil Shik;Kwon, Hyung Joong;Lee, Jae Hyouk;Park, Hyun Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.245-245
    • /
    • 2017
  • 하천 시설물은 홍수시 혹은 비상시 운영할 수 있는 경보시스템이나 관리지침 등의 마련이 필수적임에도 불구하고, 현재까지 가동보 시설물에 대한 비상시 운영 메뉴얼 및 경보시스템이 구축되지 못한 실정이다. 4대강 살리기 사업이나 하천정비사업과 같은 대표적인 하천관련 사업에서 단순한 하천 이 치수 목적뿐만 아니라 소수력 발전, 친수공간조성 등의 다목적 활용을 위하여 가동보 설치 사업이 다수 수행되었으며, 현재 국내 하천에 약 1,200여개의 가동보가 설치 운영되고 있다. 이와 같이 다목적 활용을 위하여 가동보의 수요가 급증하는데 반해, 각 설치 현장 상황에 적합한 가동보 운영지침이나 비상경보시스템이 구축되지 못한 실정이며, 적절한 지침 없이 관행적인 가동보 방류로 인한 물놀이 안전사고나 인명피해가 속출하고 있는 실정이다. 2012년 11월에는 하천 제수변 공사를 위해 전주천에 설치한 가동보를 임시적으로 방류하였는데, 하류측의 안전을 확인하지 않고 관행적으로 가동보를 방류하였고, 경보시스템의 부재로 인하여 가동보 하류측 징검다리를 건너는 유치원생들이 급류에 휩쓸리는 사고가 발생하였고, 최근 2014년 5월에는 수원시에 위치한 원천저수지 여수로 둑에 설치된 가로 34m 높이 1.6m 크기의 가동보가 공기압축기의 오작동으로 인하여 보 높이가 낮아지면서 약 30분 원천저수지 하류의 원천리천에 갑자기 무리 불어나 산책로가 침수되고 인근에 산책하던 주민들이 휩쓸려 떠내려가는 사고가 발생하였다. 해외에서도 가동보 운영 미숙으로 인하여 인명사고가 발생하는데, 2008년 11월 호주에서는 하류측 상황 점검이나 경고 방송 없이 가동보를 도복시켜 4살 여아가 급류에 사망하는 사고가 발생하였다. 국외의 경우에는, 상류측 홍수 수위나 하류측 역류 수위를 조절하기 위하여 가동보의 높이를 제어하는 시스템을 구비하고 있지만 이러한 시스템 역시 단순한 수위조절 기능으로서 가동보의 방류량을 제어하지 못하는 실정이다. 가동보를 운영하기 위한 조작시스템은 국내의 경우, 조작실의 조작판넬을 이용하여 가동보의 기립/도복 조작이나 원격 조작 기능과 같은 단순기능만을 구비하고 있어 가동보 방류시 하류측의 범람 피해를 야기하고 있다. 본 연구에서는 가동보 방류에 의한 하류측 범람 피해를 최소화하기 위하여 (1)가동보 도복에 의한 방류량 산정 알고리즘을 개발하고, (2) 방류량에 따른 하류측 수위상승 범위 예측 기법을 개발하고, (3) 가동보 도복 속도를 제어하는 방류량 제어시스템을 개발하고, (4) 가동보 방류에 의한 비상경보시스템을 개발하였다.

  • PDF

Design of height adjustable hanger using 4-bar linkage (4절 링크기구를 이용한 높이 조절 행거 설계)

  • Seyun Park;Hyuneun Lee;Yongsu Lee;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.525-530
    • /
    • 2023
  • Although double-stage hanger is used in many homes for its space utilization and ease of installation, it is inconvenient for users to take off clothes hung on the upper bar due to its high height. Therefore, this paper proposes a new type of double-stage hanger that allows users to easily hang or take out clothes hung on the upper bar while maintaining the function of the existing double-stage hanger. 4-bar link mechanism is applied so that the upper bar can come down to a convenient height with one operation. In addition, an appropriate link shape, length, and joint type are selected so that the height is adjusted three-dimensionally to prevent overlapping of clothes hanging on upper/lower bars. FEA analysis is performed to ensure that the presented hanger shape can support the load of clothes during height adjustment and the feasibility of the three-dimensional height adjustment hanger is verified through fabrication.