• Title/Summary/Keyword: 선형 변수

Search Result 2,450, Processing Time 0.035 seconds

Estimation of surface nitrogen dioxide mixing ratio in Seoul using the OMI satellite data (OMI 위성자료를 활용한 서울 지표 이산화질소 혼합비 추정 연구)

  • Kim, Daewon;Hong, Hyunkee;Choi, Wonei;Park, Junsung;Yang, Jiwon;Ryu, Jaeyong;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.135-147
    • /
    • 2017
  • We, for the first time, estimated daily and monthly surface nitrogen dioxide ($NO_2$) volume mixing ratio (VMR) using three regression models with $NO_2$ tropospheric vertical column density (OMIT-rop $NO_2$ VCD) data obtained from Ozone Monitoring Instrument (OMI) in Seoul in South Korea at OMI overpass time (13:45 local time). First linear regression model (M1) is a linear regression equation between OMI-Trop $NO_2$ VCD and in situ $NO_2$ VMR, whereas second linear regression model (M2) incorporates boundary layer height (BLH), temperature, and pressure obtained from Atmospheric Infrared Sounder (AIRS) and OMI-Trop $NO_2$ VCD. Last models (M3M & M3D) are a multiple linear regression equations which include OMI-Trop $NO_2$ VCD, BLH and various meteorological data. In this study, we determined three types of regression models for the training period between 2009 and 2011, and the performance of those regression models was evaluated via comparison with the surface $NO_2$ VMR data obtained from in situ measurements (in situ $NO_2$ VMR) in 2012. The monthly mean surface $NO_2$ VMRs estimated by M3M showed good agreements with those of in situ measurements(avg. R = 0.77). In terms of the daily (13:45LT) $NO_2$ estimation, the highest correlations were found between the daily surface $NO_2$ VMRs estimated by M3D and in-situ $NO_2$ VMRs (avg. R = 0.55). The estimated surface $NO_2$ VMRs by three modelstend to be underestimated. We also discussed the performance of these empirical modelsfor surface $NO_2$ VMR estimation with respect to otherstatistical data such asroot mean square error (RMSE), mean bias, mean absolute error (MAE), and percent difference. This present study shows a possibility of estimating surface $NO_2$ VMR using the satellite measurement.

GIS-based Disaster Management System for a Private Insurance Company in Case of Typhoons(I) (지리정보기반의 재해 관리시스템 구축(I) -민간 보험사의 사례, 태풍의 경우-)

  • Chang Eun-Mi
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.1 s.112
    • /
    • pp.106-120
    • /
    • 2006
  • Natural or man-made disaster has been expected to be one of the potential themes that can integrate human geography and physical geography. Typhoons like Rusa and Maemi caused great loss to insurance companies as well as public sectors. We have implemented a natural disaster management system for a private insurance company to produce better estimation of hazards from high wind as well as calculate vulnerability of damage. Climatic gauge sites and addresses of contract's objects were geo-coded and the pressure values along all the typhoon tracks were vectorized into line objects. National GIS topog raphic maps with scale of 1: 5,000 were updated into base maps and digital elevation model with 30 meter space and land cover maps were used for reflecting roughness of land to wind velocity. All the data are converted to grid coverage with $1km{\times}1km$. Vulnerability curve of Munich Re was ad opted, and preprocessor and postprocessor of wind velocity model was implemented. Overlapping the location of contracts on the grid value coverage can show the relative risk, with given scenario. The wind velocities calculated by the model were compared with observed value (average $R^2=0.68$). The calibration of wind speed models was done by dropping two climatic gauge data, which enhanced $R^2$ values. The comparison of calculated loss with actual historical loss of the insurance company showed both underestimation and overestimation. This system enables the company to have quantitative data for optimizing the re-insurance ratio, to have a plan to allocate enterprise resources and to upgrade the international creditability of the company. A flood model, storm surge model and flash flood model are being added, at last, combined disaster vulnerability will be calculated for a total disaster management system.

Shape Scheme and Size Discrete Optimum Design of Plane Steel Trusses Using Improved Genetic Algorithm (개선된 유전자 알고리즘을 이용한 평면 철골트러스의 형상계획 및 단면 이산화 최적설계)

  • Kim, Soo-Won;Yuh, Baeg-Youh;Park, Choon-Wok;Kang, Moon-Myung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.2 s.12
    • /
    • pp.89-97
    • /
    • 2004
  • The objective of this study is the development of a scheme and discrete optimum design algorithm, which is based on the genetic algorithm. The algorithm can perform both scheme and size optimum designs of plane trusses. The developed Scheme genetic algorithm was implemented in a computer program. For the optimum design, the objective function is the weight of structures and the constraints are limits on loads and serviceability. The basic search method for the optimum design is the genetic algorithm. The algorithm is known to be very efficient for the discrete optimization. However, its application to the complicated structures has been limited because of the extreme time need for a number of structural analyses. This study solves the problem by introducing the size & scheme genetic algorithm operators into the genetic algorithm. The genetic process virtually takes no time. However, the evolutionary process requires a tremendous amount of time for a number of structural analyses. Therefore, the application of the genetic algorithm to the complicated structures is extremely difficult, if not impossible. The scheme genetic algorithm operators was introduced to overcome the problem and to complement the evolutionary process. It is very efficient in the approximate analyses and scheme and size optimization of plane trusses structures and considerably reduces structural analysis time. Scheme and size discrete optimum combined into the genetic algorithm is what makes the practical discrete optimum design of plane fusses structures possible. The efficiency and validity of the developed discrete optimum design algorithm was verified by applying the algorithm to various optimum design examples: plane pratt, howe and warren truss.

  • PDF

FDG Uptake and a Contrast Enhancement According to Histopathologic Types in Lung Cancers (폐암의 조직학적 분류에 따른 종양의 FDG 섭취와 CT 조영증강정도에 관한 연구)

  • Han, You-Mie;Choe, Jae-Gol;Kim, Young-Chul;Park, Eun-Kyung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: The aims of this study were to analyze correlation between the maximum standardized uptake value (SUVmax) of 2-[F-18]-fluoro-2-deoxy-d-glucose (FDG) on positron emission computed tomography (PET-CT) scan and the degree of contrast enhancement on computed tomography (CT) scan in lung cancers, and to recognize the difference in SUVmax and CT enhancement between groups of different histopathologic subtypes. Materials and Methods: Our study included 53 patients of pathologically confirmed primary lung cancer, who were performed PET-CT and post-contrast chest CT. We calculated initial and delayed SUVmax (SUV1, SUV2), difference between SUV1 and SUV2 (SUVd), retention index (RI), and the degrees of CT contrast enhancement of lung cancers. We analyzed these variables for subtypes of lung cancers. Results: The values (mean$\pm$ standard deviation) were $8.3{\pm}4.4$ for SUV1, $10.7{\pm}5.7$ for SUV2, $2.4{\pm}1.6$ for SUVd, $30{\pm}14$ for RI and $47.1{\pm}14.8$ HU (Hounsfield Unit) for degree of CT contrast enhancement. The difference of SUV1 and degree of CT enhancement between subtypes was not meaningful. SUV1 showed positive correlations with SUVd (r=0.74, p<0,01) and tumor size (r=0.58, p<0.01), but no significant correlation with degree of CT enhancement (r=0.06, p=0.69). In 10 cases, there was discrepancy in the same mass between the area of highest FDG-uptake and the area of highest contrast enhancement. Conclusion: We suggest that FDG uptake in lung cancer does not have a positive linear correlation with degree of CT enhancement. And there is no significant difference in FDG uptake and degree of CT enhancement between different subtypes of lung cancers.

Electromigration Behaviors of Lead-free SnAgCu Solder Lines (SnAgCu 솔더 라인의 Electromigration특성 분석)

  • Ko Min-Gu;Yoon Min-Seung;Kim Bit-Na;Joo Young-Chang;Kim Oh-Han;Park Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.307-313
    • /
    • 2005
  • Electromigration behavior in the Sn96.5Ag3.0Cu0.5 solder lines was investigated and compared Sn96.5Ag3.0Cu0.5 with eutectic SnPb. Measurements were made for relevant parameters for electromigration of the solder, such as drift velocity, threshold current density, activation energy, as well as the product of diffusivity and effective charge number (DZ$\ast$). The threshold current density were measured to be $2.38{\times}10^4A/cm^2$ at $140^{\circ}C$ and the value represented the maximum current density which the SnAgCu solder can carry without electromigration damage at the stressing temperatures. The electromigration energy was measured to 0.56 eV in the temperature range of $110-160^{\circ}C$. The measured products of diffusivity and the effective charge number, DZ$\ast$ were $3.12{\times}10^{-10} cm^2/s$ at $110^{\circ}C$, $4.66{\times}10^{-10} cm^2/s$ at $125^{\circ}C$, $8.76{\times}10^{-10} cm^2/s$ at $140^{\circ}C$, $2.14{\times}10^{-9}cm^2/s$ at $160^{\circ}C$ SnPb solder existed incubation stage, while SnAgCu did not have incubation stage. It was thought that the diffusion mechanism of SnAgCu was different from that of SnPb.

  • PDF

A Study on the Variables Affecting the Intention to Use Healing Agriculture (치유농업 이용의도에 영향을 미치는 변인 고찰)

  • Kim, Ok Ja;Ha, Kyu Soo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.4
    • /
    • pp.59-72
    • /
    • 2018
  • The purpose of this study is to investigate the factors affecting the intention to use healing farming by setting aged readiness, rural healing supply condition, and rural healing service as independent variables. This study has been started based on the idea that it is necessary to provide healing service through healing agriculture to the rapidly increasing elderly people and urban people who need mental rest. Therefore, the purpose of this study is to find out the various factors influencing intention to use healing agriculture through empirical analysis. Second, we want to examine whether the variables influenced the intention to use more. Third, based on the results of these tests, we suggest the policy for activation of healing agriculture by examining the factors necessary for the promotion of physical and mental health of the elderly in the aging society and the revitalization of healing agriculture for the mental healing of the urban people. For this study, a questionnaire survey was conducted for men and women over 30 years old, and the final 356 copies were analyzed. The validity of the research hypothesis was verified by linear regression analysis. The results of the analysis are as follows. First, the physical preparation, emotional preparation, and economic preparation of aged care preparations were found to have a significant effect on intention to use. Second, natural landscape, accessibility, and stability of rural healing supply conditions were found to have a significant effect on intention to use. But economics and expertise were dismissed. Third, crop cultivation, animal medication and healing facilities of rural healing service were proved to have significant influence on intention to use. In order to increase the utilization of healing agriculture, it is necessary for the consumer to be well prepared for aging. In rural healing supply conditions, accessibility and safety should be provided for healing facilities in rural healing services.And to increase the intention to use it.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

A Correlation Between Vertical Fixation Disparity and Stereopsis at Near (근거리에서 수직주시시차와 입체시와의 관계)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2013
  • Purpose: To investigate a correlation between vertical fixation disparity and stereopsis by analyzing distribution of types of vertical fixation disparity. Methods: In this study, RANDOT(R) stereotest partly using random dot was used in stereopsis tests. The vertical fixation disparity in close proximity categorized fixation disparity slope into six types on the basis of the result of measurement in when two thin lines, one for one eye looks, become overlapped as a line by adding into prism with Wesson fixation disparity card while maintaining a distance of 25 cm from patients. Results: In the types of near vertical fixation disparity curve, targeting 43 people, the first type 55.82% was the most distributed, the second type is the least 23.25%, the third type of 4.65%, the fourth type of 4.65%, the fifth type of 6.98%, the sixths types of 4.65% were distributed. The result of a correlation analysis, which shows the degree of linear correlation between two variables, represented that stereopsis is not correlated with Y-intercept (r = -0.07) which show vertical fixation disparity, associated phoria (r = -0.03) and dissociated phoria (r = -0.00), but it was not statistically significant (p>0.05). Fixation disparity slope of vertical fixation disparity (r = 0.36) was shown to have a positive correlation with stereopsis. It has a low positive correlation and a meaningful statistics (p<0.05). The Y-intercept which indicates vertical fixation disparity was also not associated with stereopsis (r = -0.07) and dissociated phoria (r = -0.03), and this was not statistically significant (p>0.05), while it had a high correlation as well as a statistically significant with associated phoria (r = 0.89). There was a negative correlation between Y-intercept and fixation disparity slope of vertical fixation disparity (r = -0.33). It showed a low relationship but statistically valuable (p>0.05). As a result of regression analysis, the stereopsis was changed as 7.631" if vertical fixation disparity changes 1' and the vertical fixation disparity changed as 0.017' if stereopsis changes 1', and the change was statistically significant (p<0.05). Conclusions: The study shows that there is a low correlation between stereopsis and vertical fixation disparity, and it is difficult to determine stereopsis only using vertical fixation disparity. Therefore, it suggests other factors above vertical fixation disparity have greater influence on stereopsis.