A Study on the Measurement of the Personal Exposure Dose by Film Badge Dosimeter (필름배지선량계에 의한 개인피폭선량 측정에 관한 연구)

  • Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.37-50
    • /
    • 1994
  • The experimental evaluation of exposure conversion formula using the relationship between optical photo-density, exposure dose and the quality of radiation characteristics of radiation energy to X-ray and ${\gamma}-rays$. The film badge dosimeter is analysed by exposure conversion formula which evaluate image fading characteristics for development time and directional characteristics for incident beam angle. In conclusion, exposure conversion formula evaluated of this study is satisfied with quality decision criterion of the film badge dosimeter.

  • PDF

Evaluation of image Quality for Radiographic positioning using IEC Radiation Quality & Clinical condition (IEC 선질과 임상조건을 이용한 방사선영상의 품질평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.177-178
    • /
    • 2015
  • 디지털방사선영상시스템의 영상 품질을 비교하기 위해 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 잡음력 스펙트럼(NPS)을 이용하여 영상 품질평가를 하였다. IEC61267 선질을 사용하여 IEC62220-1에서 제시하는 기하학적인 조건과 실제 임상에서 사용되어지는 기하학적인 조건을 사용하여 그리드 및 부가필터, 임상선량을 이용하여 edge 팬텀을 사용하여 MTF, NPS값을 측정하였다. 그리드사용 유 무, 부가필터사용 유 무, kV, 임상선량(mAs), 영상검출기까지의 거리에 따른 MTF 결과는 임상조건 100cm, 180cm과 IEC62220-1 기하학적인 조건 150cm에서 MTF 공간주파수 측정값은 비슷하게 나타났으며, 오히려 임상조건 100cm에서 공간주파수가 높게 나타나는 경우도 있었다. NPS 결과는 선량(mAs)이 증가함에 따라 감소함을 나타내었다. IEC61267 선질을 이용한 영상품질평가에서는 IEC62220-1기하학적인 조건을 이용한 품질평가보다 임상조건 기하학적인 조건을 사용한 영상의 품질이 좋았다. 본 논문의 영상특성 평가 연구 결과들을 바탕으로 향후 IEC 표준의 영상평가에서 제시하는 평가방법보다는 임상 조건을 적용한 영상특성 평가방법을 적용한다면 실제 임상의 디지털방사선영상시스템의 영상품질을 적절하게 유지할 수 있을 것으로 사료된다.

  • PDF

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.