• Title/Summary/Keyword: 선예도

Search Result 48, Processing Time 0.123 seconds

Consideration of the X-ray Spectrum Change and Resolution According to Added Filters, SID, A-Si (CsITl) in the Imaging System (A-Si(CsITl) 영상시스템에서 부가필터, SID에 따른 X선 스펙트럼변화와 해상력에 대한 고찰)

  • An, Hyeon;Kim, Jung-Hoon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.681-688
    • /
    • 2016
  • This study assess their quality of radiation on analysis of the spectrum of resolution suggesting IEC 61267 in radiation quality that RQA3, RQA5, RQA7, RQA9 and combination of clinical condition using several quality of radiation. In experiments edge method first, the spatial resolution assessment used image of the additional filter and SID is obtained the IEC 62220-1, spatial resolution and sharpness of the obtained image was evaluated in the MTF value 10%(0.1), MTF value 50%(0.5) using a Matlab program. Second, MCNPX simulation used spatial resolution analysis was radiation quality particle fluence and spectrum analysis in energy. As a result, make use of additional filter, image quality evaluation of SID that RQA3 radiation quality combination qualification is higher spatial resolution and sharpness make unused of additional filter and SID 100cm. RQA7 radiation quality combination qualification is higher that spatial resolution make unused of additional filter and SID 150cm. RQA9 radiation quality combination qualification is higher that spatial resolution and sharpness make used of additional filter and SID 180cm. spectrum analysis of radiation quality by reducing consequent errors occurring in the experiment that error due to the reproducibility of the X-ray tube, occur in an error of correction the detector suggest ideal conditions from spectrum analysis through MCNPX simulation. In conclusion, by suggesting spatial resolution and sharpness of result for various radiation quality, It provide basic data that radiation quality condition and quantitative assessment method for laboratory in clinical using detector evaluation.

Usefulness of Parallel Imaging Technique in MRCP for Liver Donor (간 공여자의 자기공명췌담관조영술에서 병렬 영상 기법의 유용성)

  • Lim, woo-taek;Jung, hong-ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.149-150
    • /
    • 2015
  • 병렬영상기법(parallel imaging technique)은 하나의 수신 코일을 사용하는 기존의 방식과 달리 다수의 수신코일을 이용하여 데이터를 획득하는 기법으로서 검사시간 및 공간해상도를 향상시키기 위해 사용된다. 본 논문은 간 공여자의 자기공명영상 췌담관 조영술에서 간담도 영상의 선예도 향상을 위한 병렬영상기법의 유용성을 연구하고자 하였다.

  • PDF

Observer Preferable Sharpness Enhancement Considering Distributions of Edge Characteristics (경계선 특성을 고려한 관측자 선호 선예도 개선 방법)

  • 홍상기;정재영;김대희;조맹섭
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.275-278
    • /
    • 2002
  • Sharpness enhancement, which strengthen the edge(high frequency) of image, is widely studied for image processing research area. In this paper, psychophysical experiment is conducted by the 20 observers with simple linear unsharp masking for sharpness enhancement. The experimental results extracted using z-score analysis and linear regression suggests observer preferable sharpness enhancement method for digital television.

  • PDF

Picture Quality Compensation for PDP-TV in Shutter-Glass type 3D Image (셔터 글래스 방식 3D 영상에서의 PDP-TV 화질 보상)

  • Choi, Seog-Gweon;Lee, In-Soo;Kim, Kwang-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.133-140
    • /
    • 2014
  • 3D stereoscopic display is becoming increasingly common. Most stereoscopic displays still require the viewers to wear 3D glasses to watch 3D contents. As it is widely known, especially in shutter glass method, 3D glasses normally cause to reduce the perceived colorfulness and sharpness considerably as well as brightness. In this paper, we have estimated and analyzed the degradation of perceptual brightness in 3D images viewed through the shutter glasses by using CIECAM02 model. This study focuses on loss of colorfulness and sharpness when PDP-TV is watched at 3D mode in shutter-glass type 3D-TV. We analyze perceptual colorfulness and sharpness of 3D display with glasses and propose a method to compensate 3D colorfulness and sharpness for the best 3D experience.

Cochineal Printing Using Pretreated Fabrics with Chitosan (키토산이 전처리된 직물을 이용한 코치닐 날염)

  • Kim, Kyung-Sun;Jeon, Dong-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.10
    • /
    • pp.1644-1654
    • /
    • 2009
  • The concentration of dye uptake and the fastness improved when cotton and silk fabrics were treated with chitosan, a natural polymer. In this study, the effect of chitosan treatment was reviewed after the printing of cotton and silk fabrics padded with chitosan. When the change of physical and mechanical properties of printed fabrics was reviewed (as the concentration of chitosan increased) the thickness and weight increased a little, and the air permeability increased significantly than those untreated with chitosan. The dye uptake increased, accompanying a darker color shade, and the wash fastness increased 1/2-1 grade. The analysis results of enlarged images of printed patterns indicated that the width and area deformations were minimal as the concentration of chitosan increased when compared to untreated fabrics. Therefore, the dyeability and pattern quality were excellent after printing the chitosan-treated cotton and silk fabrics with cochineal dyestuff.

Sharpness Enhancement of Tooth X-ray Images Through Elimination of Complicated Background (복잡한 배경 제거를 통한 치아 X-ray 영상의 선예도 개선)

  • Kun-Woo Na;Keun-Ho Rew
    • Journal of Information Technology Applications and Management
    • /
    • v.30 no.1
    • /
    • pp.11-19
    • /
    • 2023
  • To remove unnecessary background from tooth X-ray images and enhance the sharpness of tooth and gum images, image processing techniques including contrast adjustment and histogram equalization are used. The introduction of two methods for detecting the boundary of the tooth and gum region and separating the tooth and gum from the background. In both cases, the background of the tooth X-ray images could be removed as a result, improving the quality of the images. The proposed method improves MTF (Modulation Transfer Function), an image performance indicator, as a result of measuring MTF. The original image's spatial frequency ranged from 4.73 to 11.40 lp/mm at the 10% response, whereas the proposed image's spatial frequency ranged from 10.90 to 11.85 lp/mm, giving uniformly enhanced results. In contrast, tooth and gums could not be completely separated from the background using Apple's Lift subject from background function.

Correction Method of Slit Modulation Transfer function on Digital Medical Imaging System (디지털 의료영상에서 슬릿법에 의한 Modulation Transfer Function의 보정방법)

  • Kim, Jung-Min;Jung, Hoi-Woun;Min, Jung-Whan;Im, Eon-Kyung
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • By using CR image pixel data, We examined the way how to calculate the MTF and digital characteristic curve. It can be changed to the text-file(Excel) from a pixel data which was printed with a digital x-ray equipment. In this place, We described the way how to figure out and correct the sharpness of a digital images of the MTF from FUJITA. Excel program was utilized to calculate from radiography of slit. Digital characteristic curve, Line Spread Function, Discrete Fourier Transform, Fast Fourier Transform digital specification curve, were indicated in regular sequence. A big advantage of this method, It can be understood easily and you can get results without costly program and without full knowledge of computer language. It shows many different values by using different correction methods. Therefore we need to be handy with appropriate correction method and we should try many experiments to get a precise MTF figures.

  • PDF

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

Comparison of the Modulation Transfer Function of Several Image Plate (Image Plate(IP) 영상의 MTF 비교)

  • Kim, Chang-Bok;Lee, Yang-Sup;Kim, Young-Keun;Lee, Seong-Kil;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.25-29
    • /
    • 2004
  • Among the digital radiography systems, the computed radiography Image Plate Detector System is most frequently being used for the general radiography and also this system commonly diffracts the x-ray images since it is the system that is influenced by the light diffusion from the fluorescent substances. In this study, by using the X-ray Generator, a comparative analysis has been made between 2 different models of computer radiography image plate investigate each model's resolution and sharpness through the modulation transfer function(MTF) measurement. For the analysis, two image plates for general radiography one Fuji ST-VN model(more than 3years old) and one Fuji ST-VL model(less than 2years old) that are currently being used in "Hospital A" were sampled for the MTF measurement here. As the experimental method for this study, the resolution chart method has been carried out by using X-ray generator. Also all the experimental data were printed out by laser printer and measured by microdensitometer. As the results of the experiment carried out in this study, some differences have been found between the two different IP models and Fuji ST-VL has shown its excellence in both of the resolution and the sharpness fields.

  • PDF