• Title/Summary/Keyword: 선암

Search Result 528, Processing Time 0.024 seconds

Long-term Survival of Recurrent Pancreatic Cancer Treated with Tumorectomy and Stereotactic Body Radiation Therapy (수술 후 재발한 췌장암에서 종양절제술과 정위적 체부 방사선치료로 장기간 생존을 보인 환자)

  • Jong Hwa Won;Ji Kon Ryu;Min Su You
    • Journal of Digestive Cancer Research
    • /
    • v.6 no.2
    • /
    • pp.73-77
    • /
    • 2018
  • A 70-year-old female diagnosed with pancreatic ductal adenocarcinoma was treated by pylorus-preserving pancreaticoduodenectomy (PPPD) and adjuvant concurrent chemoradiotherapy with 5-fluorouracil. Pancreatic ductal adenocarcinoma pT3N0 (stage IIA) was pathologically confirmed. Abdominal computed tomography (CT) findings 14 months after PPPD showed 10 mm sized solitary liver metastasis in segment 3. After 12 cycles of gemcitabine and 9 cycles of capecitabine plus oxaliplatin, the metastatic nodule increased in size to 27 mm. Tumorectomy at segment 3 of liver was done. 25 months after tumorectomy, chest CT showed 23 mm sized cavitary nodule in right upper lobe of lung. The result of percutaneous biopsy favored metastatic adenocarcinoma. Two sets of stereotactic body radiation therapy were done and the patient has survived without further disease progression for 6 years after initial diagnosis. This case suggests that selected population of recurrent pancreatic cancer patients with solitary liver or pulmonary metastasis can be treated by resection of metastatic site and ablative therapies.

  • PDF

Dose Evaluation of TPS according to Treatment Sites in IMRT (세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가)

  • Kim, Jin Man;Kim, Jong Sik;Hong, Chae Seon;Park, Ju Young;Park, Su Yeon;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.181-186
    • /
    • 2013
  • Purpose: This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. Materials and Methods: The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. Results: In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Conclusion: Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made.

  • PDF

Comparison of Beam Delivery Modes in Prostate Cancer Proton Therapy: A Treatment Planning Comparison Study (전립선암 환자 양성자치료 시 빔 전달방식에 따른 치료계획 비교)

  • Kim, Youn Young;Youm, Doo Seok;Jang, Yo Jong;Kang, Dong Yun;Park, Jeong Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.153-158
    • /
    • 2013
  • Purpose: After making two plans, the Double Scattering (DS) Mode and The Pencil Beam Scanning (PBS) Mode, of patients on early prostate cancer, we not only compare the dose conformity and the dose homogeneity by analyzing each DVH, CN and HI, but also evaluate normal structures's sparing effect on each mode. Materials and Methods: Planes about nine patients, who did proton therapy, on prostate cancer was setted using the Eclipse proton external beam planning system. The prescription dose, every $2.5 Gy{\times}28$ fractions=70 Gy, was delivered to the PTV. The CN and the HI were getted by anlazing each DVHs for the DS Plan and the PBS Plan. Also, normal structures' %volumes according to dose of the PBS are campared with those of the DS. Results: The average CN of the PTV is increase 16.63% from DS $0.68{\pm}0.07$ to PBS $0.79{\pm}0.01$, and the average IN of the PTV is decrease -22.66 % from DS $0.12{\pm}0.03$ to PBS $0.09{\pm}0.01$. The PBS has litter %Volumes of normal structures than the DS about every patient except Rectum. The average %Volume of Left Femoral Head receiving ${\geq}30$ Gy shows most high decreasing rate, -79.93%, from DS to PBS and the average %Volume of Rectum receiving ${\geq}70$ Gy shows most low decreasing rate, -3.03%, from DS to PBS. Conclusion: Therefore, the PBS is more effective achieving the dose conformity and the dose Homogeneity than DS, and better to reduce unnecessary dose arriving normal structures, especially the femoral heads.

  • PDF

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

Permanent Brachytherapy of Localized Prostate Cancer: Preliminary Results (국소 전립선암의 영구적 근접치료: 조기 결과)

  • Park, Hye-Li;Chang, Sei-Kyung;Kim, Ja-Young;Lee, Bo-Mi;Ko, Seong-Young;Kim, Sung-Joon;Shin, Hyun-Soo
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.71-82
    • /
    • 2011
  • Purpose: To evaluate the biochemical control rate and the rate of side effects after performing permanent brachytherapy of localized prostate cancer. Materials and Methods: 67 patients with localized prostate cancer were treated with brachytherapy between April 2007 and December 2008. Of these, 43 patients who were followed up and did not receive external radiotherapy were evaluated for the change in prostate specific antigen (PSA) level and the occurrence of side effects. In total, 18 patients were classified as low risk, 19 patients as intermediate risk, and 6 patients as high risk. The prescription dose was 145 Gy. Results: A PSA increase greater than 2 ng/mL occurred in 2 patients (4.7%). Radiation Therapy Oncology Group (RTOG) grade 1 and 2 acute urologic complications (UC) occurred in 40 and 3 patients, respectively. Further, 5 patients had RTOG grade 1 acute rectal complication (RC). The numbers of RTOG grade 1, 2, and 3 chronic UC were 1, 4, and 1, respectively. The numbers of RTOG grade 1, 2, and 4 chronic RC were 5, 10, and 3, respectively. The statistically significant risk factors (RF) of acute RC were the minimal dose in the most irradiated 0.1 cc volume ($D_{0.1cc}$, p=0.041) and absolute volume receiving 150% of the prescribed dose ($V_{150cc}$, p=0.038) in the entire rectum (ER). The percentage ($V_{100%}$, p=0.019) and absolute volume ($V_{100cc}$, p=0.047) in the involved rectum (IR) were also statistically significant. The RF of chronic RC were $V_{100%}$ (p=0.011) in the ER and the $D_{0.1cc}$ (p=0.049), $V_{100cc}$ (p=0.023) in the IR. The number of used seeds were related with acute UC (p=0.028). Conclusion: Permanent brachytherpy of localized prostate cancer showed a favorable short term biochemical control rate. As such, selective intermediate and high risk patients can be managed with permanent brachytherapy. The effort to reduce rectal complication is also necessary.

The Incidences and Characteristics of Malignant Pleural Effusions According to Histologic Types (악성 흉막 삼출증의 조직학적 아형에 따른 빈도와 특성)

  • Yim, Jae-Joon;Kim, U-Jin;Lee, Jae-Ho;Yoo, Chul-Gyu;Chung, Hee-Soon;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.3
    • /
    • pp.565-573
    • /
    • 1998
  • Malignant pleural effusions are most commonly associated with lung cancers, however, it also can be resulted from breast cancers, ovarian cancers, stomach cancers and so on. According to the their histologic types, adenocarcinoma have been known as the most common cell type of malignant pleural effusions and squamous cell carcinoma is rare. We herein present incidences, clinical characteristics and survivals of malignant pleural effusions according to their cell types and primary diseases. The objects are 84 malignant pleural effusion patients diagnosed by pleural fluid cytologic examination or pleural biopsy from Jan. 1992 to May. 1997 in Seoul National University Hospital. A retrospective chart review on their histologic types, biochemical parameters and survivals is described. Among 84 patients, 52 were males and the other 32 were females with 1.6:1 of male and female ratio and their mean age was 57.6 years old. Common symptoms of them wele dyspnea, cough, sputum and pleuritic chest pain. The proportions of bloody nature of effusion, lymphocyte dominant pleural effusion, exudative effusions were 66%, 39% and 93%, respectively. They consisted of 54 cases of adenocarcinoma(33 cases of them were lung cancers), and 10 cases of squamous cell carcinoma (8 cases of them were lung cancers), 10 cases of malignant lymphoma, 8 cases of small cell lung cancer and a case of mesothelioma and leukemia. There was no differences in characteristics of effusions, clinical features and survivals between each histologic cell types. Analyzing them according to primary diseases, no difference except longer survivals in malignant pleural effusions from breast cancer than from other cancers was observed. In conclusion, considering the incidences of histologic types of lung cancers during same period (squamous cell carcinoma; 47%, adenocarcinoma; 33%, small cell lung cancer; 12% and large cell carcinoma; 2%), malignant pleural effusions more likely occurred in adenocarcinoma than other cell types of lung cancers and there was no significant difference of clinical characteristics between histologic types.

  • PDF

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

Robust Planning of Intensity-modulated Proton Therapy for Prostate Cancer (전립선암 치료를 위한 세기조절 양성자 로버스트 치료계획)

  • Park, Su Yeon;Kim, Jong Sik;Park, Ju Young;Park, Won;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2013
  • Purpose: The aim of this study is to evaluate the dosimetric properties of robust planning strategy for plain intensity-modulated proton therapy (IMPT) taking into account of the uncertainties of effective proton range and set up error as compared to photon intensity-modulated radiation therapy (photon-IMRT) in prostate cancer treatment. Materials and Methods: The photon-IMRT (7 beams, step & shoot), plain-IMPT (2, 4, and 7 portals), and robust- IMPT plans, which was recalculated the plain-IMPT based on the uncertainties of range error (${\pm}5%$) and set up error (0.5 cm), were evaluated for five prostate cancer patients prescribed by 70 Gy/35 fractions. To quantitatively evaluate the dose distributions, several parameters such as maximum dose, minimum dose, mean dose, conformity index (CI), and homogeneity index (HI) for PTV as well as dose-volume index of VxGy for OARs were calculated from dose-volume histograms. Results: Robust-IMPT showed superior dose distributios in the PTV and OARs as compared to plain-IMPT and photon-IMRT. Like plain-IMPT, robust-IMPT were resulted in dose fluctuation around OARs, while better homogeneity and conformity in PTVs and lower mean dose in OARs as compared to photon-IMRT. Conclusion: In consideration with the effective range correction and set up movement using robustness in IMPT plan, the dosimetric uncertainties from plain-IMPT could substantially reduce and suggest more effective solutions than photon-IMRT in prostate cancer treatment.

  • PDF

Diagnostic Value of Serum CYFRA 21-1 in Lung Cancer (폐암에서 혈중 CYFRA 21-1의 진단적 가치)

  • Yoon, Hyun-Dae;Kim, Ki-Deok;Chung, Jin-Hong;Lee, Hyung-Woo;Lee, Kwan-Ho;Lee, Hyun-Woo;Cho, Ihn-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.149-155
    • /
    • 1995
  • Background: Cytokeratin 19 is 40KD acidic molecule whose distribution is restricted to simple or pseudo-stratified epithelia, such as the epithelial layer of the bronchial tree. Immunohistochemical study have shown that cytokeratin 19 is overexpressed in lung carcinoma tissue. An immunoradiometric assay, CYFRA 21-1 has been developed using two monoclonal antibody, BM 19-21 and KS 19-1, reactive to different epitopes on cytokeratin 19. We studied the diagnostic value of CYFRA 21-1 in lung cancer. Method: The serum CYFRA 21-1 level using immunoradiometric kit(ELSA-CYFRA 21-1) was measured in 54 patients who admit to Yeungnam University Hospital from April, 1993 to August, 1994. Lung cancer group was 39 primary lung cancer patients(19 patients with squamous cell carcinoma, 11 patients with adenocarcinoma and 9 patients with small cell carcinoma). Control group was 15 patients with non malignant lung diseases(8 patients with pulmonary tuberculosis, 3 patients with chronic obstructive pulmonary disease, 2 patients with pneumonia and 2 patients with chronic obstructive pulmonary disease combined with pulmonary tuberculosis). Results: The mean serum value of CYFRA 21-1 was $20.2{\pm}4.7ng/ml$ in squamous cell carcinoma, $7.2{\pm}1.6ng/ml$ in adenocarcinoma and $15.5{\pm}4.7ng/ml$ in non-small cell lung cancer. The serum value of CYFRA 21-1 in control group was $1.7{\pm}0.5ng/ml$. All of the serum values of 3 histologic types were significantly higher than that of control group(p<0.01). The serum value of CYFRA 21-1 of squamous cell carcinoma was significantly higher than that of adenocarcinoma(p <0.05). Serum value of CYFRA 21-1 in small cell lung cancer was $2.9{\pm}0.9ng/ml$ and not significantly different compared with control group. Using cut off value of 3.3ng/ml, sensitivity and specificity was 11.1%, 65.2% in small cell lung cancer, 70.0%, 62.5% in non-small cell lung cancer, 73.7%, 75% in squamous cell carcinoma and 63.6%, 78.9% in adenocarcinoma, respectively. Conclusion: The serum levels of CYFRA 21-1 may be useful in diagnosis of non-small cell lung carcinoma, especially in squamous cell carcinoma with its high specificity.

  • PDF

A Study on Clinical Progress of the Metastatic Adenocarcinoma of Pleura (전이성 흉막선암의 임상 경과에 관한 연구)

  • Yang, Seong-Wook;Lee, Tae-Kwan;Lee, Tae-Heon;Cho, Deok-Su;Baek, Hyeon-Seon;Kim, Ji-Young;Lee, Hye-Kyung;Kim, Kwi-Wan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.156-164
    • /
    • 1995
  • Background: We had undergone this study to investigate clinical progress of this disease and to decide the role of aggressive diagnostic approaches, the efficacy of treatments and prognoses. Methods: A retrospective study was done on 113 patients who had been diagnosed to metastatic adenocarcinoma of pleura by pleural fluid cytology(106 cases) or pleural needle biopsy(22 cases), at Presbyterian Medical Center, from Jan. 1990 to Dec. 1994. Results: 1) The patients were composed of 59 males(52.2%) and 54 females(47.8%), and the mean age distribution was $57.4{\pm}12.1$ years. 2) The site of origin was lung cancer 46.9%(53/113), stomach cancer 20.4%(23/113), breast cancer 11.5%(13/113), and unknown primary site 6.2%(7/113 cases), as a whole. In male, lung cancer was 55.9%(33/59), stomach cancer was 28.8%(17/59), and in female, lung cancer was 37%(20/54), breast cancer was 24.1%(13/54) of cases. 3) The cardinal symptoms were dyspnea(69%), cough(61%), chest pain(50%), weight loss(50%), anorexia(49%), sputum(43%), malaise(30%). 4) The pleural fluid findings were exudative in 94.4%(102/108), serosanguinous or bloody in 36~53%, unilateral involvement in 74.3%(84/113) of cases, and lymphocyte predominance($71{\pm}27%$) in differential count of WBC. 5) CEA levels in pleural fluid or plasma were over 10ng/ml in 60.6%(40/66), and ADA levels in pleural fluid were under 40U/L in 95%(57/60) of cases. 6) The patients were managed by various methods, but the efficacy of treatment was uncertain. 7) The mean survival time was $12.7{\pm}13.5$ weeks. Conclusion: It seems to be no effective treatment methods yet and the prognosis was very poor in this disease, so the objectives of diagnostic approaches and treatment methods should be directed to early diagnosis, treatment and prevention of curable disease. And we must make our best endeavors to lengthen the survival time and improve the quality of patients' life.

  • PDF