• Title/Summary/Keyword: 선별검사

Search Result 749, Processing Time 0.036 seconds

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

Notification App for Infectious Disease Test Reservation (감염병 검사 예약을 위한 알림 앱)

  • Je-Seong, Hwangbo;Kang-Yoo, Seo;Seung-Soo, Shin
    • Advanced Industrial SCIence
    • /
    • v.1 no.2
    • /
    • pp.30-36
    • /
    • 2022
  • Even in 2022, when medical science is highly developed, pandemic infectious diseases continue to occur. COVID-19, which occurred in 2019, is highly contagious and has caused many infections. In Korea, temporary screening clinics, such as screening clinics and respiratory clinics, have been added to prevent the spread of COVID-19, but there are problems such as a bottleneck due to the large number of people who want to take the test, and this creates a bottleneck. In order to solve the problem, this study aims to identify people who want to be tested for COVID-19 in a screening clinic in real time. It uses a real-time database to link with screening clinics and provides users with the real-time status of each screening clinic. Using the app, users can check the status of screening clinics in real time and can select a clinic smoothly.

The First Newborn Screening Study of T-Cell Receptor Excision Circle and κ-Deleting Recombination Excision Circle for Severe Combined Immunodeficiency in Korea: A Pilot Study (국내 최초 T-Cell Receptor Excision Circle과 κ-Deleting Recombination Excision Circle 신생아 선별검사에 관한 연구)

  • Son, Sohee;Kang, Ji-Man;Kim, Jong Min;Sung, Sein;Kim, Yi-Seoul;Lee, Haejeong;Kim, BitA Reum;Lee, Yeon Kyoung;Ko, Sun Young;Shin, Son Moon;Kim, Yae-Jean
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.3
    • /
    • pp.134-140
    • /
    • 2017
  • Purpose: Severe combined immunodeficiency (SCID) is the most serious form of primary immunodeficiency. Infants with SCID are susceptible to life-threatening infections. To establish newborn screening for SCID in Korea, we performed a screening test for T-cell receptor excision circle (TREC) and ${\kappa}$-deleting recombination excision circle (KREC) in neonates and investigated the awareness of SCID among their parents. Methods: Collections of dried blood spots from neonates and parent surveys were performed at the Samsung Medical Center and Cheil General Hospital & Women's Healthcare Center in Korea. The amplification crossing point (Cp) value <37.0 was defined as TREC/KRECpositive based on cutoff values from measuring multiplex real-time polymerase chain reaction. A Cp value >39.0 was defined as negative. Results: For TREC/KREC screening, 141 neonates were enrolled; 63 (44.7%) were male. One hundred forty neonates (99.3%) had positive TREC/KREC results at the time of the initial test; 82.3% and 75.9% were positive and 17.0% and 23.4% were weakly positive for TREC and KREC, respectively. In one neonate (0.7%), the initial TREC/KREC test result was negative. However, repeated tests obtained and confirmed a positive result. For an awareness survey, 168 parents were engaged. Only 2% of parents (3/168) knew that the newborn screening test for SCID had been introduced and performed in other countries. Eighty-four percent of parents (141/168) replied that nationwide newborn SCID screening should be performed in Korean newborns. Conclusions: In this study, newborn SCID screening was performed along with assessment of public awareness of the SCID test in Korea. The study results showed that newborn SCID screening can be readily applied for clinical use at a relatively low cost in Korea.

A Diagnostic Algorithm after Newborn Screening for 21-hydroxylase Deficiency (선천성 부신 과형성증(21-hydroxylase 결핍)의 신생아 선별 검사 후 진단 알고리즘)

  • Cho, Sung Yoon;Ko, Jung Min;Lee, Kyung-A
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.16 no.2
    • /
    • pp.70-78
    • /
    • 2016
  • 21-hydroxylase deficiency (21-OHD), most common form of congenial adrenal hyperplasia, is categorized into classical forms, including the salt-wasting (SW) and the simple virilizing (SV) types, and nonclassical (NC) forms based on the severity of the disease. Newborn screening for 21-OHD has been performed in Korea since 2006. $17{\alpha}$-hydroxyprogesterone (17-OHP) is a marker for 21-OHD and is measured using a radioimmunoassay or a fluoroimmunoassay. Premature and low birth weight infants are likely to give false positive 17-OHP findings, therefore, cutoff values for these infants should be determined based on gestational weeks or birth weight. ACTH simulation test is helpful when the 17-OHP shows equivocal increase, and it is gold standard for diagnosis of NC type. Recently, liquid chromatography linked with tandem mass spectrometry was developed for rapid, highly specific, and sensitive analysis of multiple analytes. Molecular analysis of CYP21A2 is useful for confirming diagnosis of mild SV or NC type, predicting prognoses, and genetic counseling. In order to make newborn screening for 21-OHD more efficient, early detection of boy with SW type, early determination of girl with ambiguous genitalia, detection of NC type, and overcoming of false positive in premature and low birth weight infants should be considered. Above all, early treatment should be started when the patient is suspected as having 21- OHD clinically before confirming the diagnosis to prevent adrenal crisis. Here, author reviewed recent articles of guideline and proposed guideline for 21-OHD.

  • PDF

Prediction of Obstructive Coronary Artery Disease by Coronary Artery Calcification Finding on Low-dose CT Image for screening of lung diseases: Compared with Calcium Scoring CT (폐질환 선별검사를 위한 저선량 CT영상의 관상동맥 석회화 소견으로부터 폐쇄성 관상동맥질환 예측: 석회화수치 CT검사와 비교)

  • Lee, Won-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.333-341
    • /
    • 2011
  • To compare between calcium scoring CT (CSCT) and Low-dose CT (LDCT) image finding for coronary artery calcification (CAC) in screening of lung disease by MDCT. A total of 61 subjects who retired-workers exposed to inorganic dust were performed LDCT and CSCT by using a MDCT scanner on the same day, after be approved by the institutional review board, and obtaining the written informed consent from all subjects. LDCT images were read for detecting lung diseases as well as CAC by a experienced chest radiologist, then the subjects were divided either the positive group with CAC or the negative group without it. The CSCT was used to quantify and detect the presence of calcification in the coronary artery, and score of CAC calculated by using a Rapidia software (ver 2.8). In all coronary arteries, calcium score of positive group was higher better than that in negative group, especially in the total calcium (13.7 vs. 582.9, p=0.008) and the left anterior descending artery (3.2 vs. 249.0, p=0.006). CAC findings between CSCT and LDCT image were showed excellent agreement in cut-off point 100(K-value=0.80, 95% CI=0.69-0.91) from total calcium score. CAC findings on LDCT images showed the higher relation with CSCT. Therefore, the obstructive coronary artery disease could be predicted by CAC on LDCT images for screening of lung diseases.

Lung Cancer Screening (폐암 조기 진단)

  • Kim, Ju Ock
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.3
    • /
    • pp.207-213
    • /
    • 2006
  • 기존의 폐암 발생의 고위험군(나이. 흡연력, $FEV_1$, 가족력, 직업적 발암물질의 노출력, 기존의 폐암 및 두경부 종양)에 대한 저선량 나선식 CT와 기관지 내시경 검사로 선별 검사 시 폐암의 유병률은 높아야 2%내외이고 대부분 그보다 낮은 것으로 알려져 있다. 특이도는 49-90%, 양성예측률은 10%이하로 선별검사 시 불필요한 검사를 초래하고 그에 따른 이환률과 사망률을 증가시키며 비용적인 문제를 야기하는 것으로 알려져 있다. 이에 기존의 고위험군에 대해 대상 환자를 더욱 더 좁힐 필요가 있으며, 이는 실제 임상적으로 이용 가능한 생물학적 표지자의 개발의 필요성이 있다고 하겠다. 그러나 현재까지 알려진 폐암조기검진에 대한 각종 진단 수기 중애서 상기의 3가지 방법(저선량 MDCT, 자가형광기관지경 및 객담내 MAGE)을 한꺼번에 시행하는 program은 비용적인 문제는 있지만 시도해 볼 만한 방법이라고 생각된다.

The Effect of a Time Management Program on Drinking-Habit and Self-Efficacy in College Student With Problematic Drinking (시간관리 프로그램의 적용이 문제음주 대학생들의 음주습관과 자기효능감에 미치는 영향)

  • Park, Young-Ju;Kim, Yu-Seok;Park, Su-Jung;Park, Ji-Yeon;Bang, Ji-Hyun;Song, Ji-Won;Chang, Moonyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.13 no.1
    • /
    • pp.57-66
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effect of a time management program on self-efficacy and drinking-habit of college student with problematic drinking. Methods : Thirty subjects with problematic drinking were randomly assigned to either a experimental group or control group. The intervention applied to the experimental group was a time manage program which was consisted of two times of sessions per week and provided for five weeks. There was no specific intervention applied to the control group. Alcohol Use Disorder Identification Test-Korean (AUDIT-K) was used to measure problematic drinking behaviors and Self-Efficacy Test was used to evaluate self-efficacy of the subjects. Results : Experimental group showed a significant improvement in AUDIT-K after intervention between groups. In change scores within group, experimental group showed a significant improvement in both AUDIT-K and Self-Efficacy Test, and control group showed a significant improvement in AUDIT-K only. Conclusion : The result of this study showed that time management program is an effective method for college student with problematic drinking.

Incidence of Vesicoureteral Reflux and Renal Scar in Asymptomatic Siblings of Patients with Primary Vesicoureteral Reflux (선천성 방광요관역류 환아의 형제자매에서 방광요관역류와 신반흔의 유병률)

  • Yu Je-Yun;Suck Hyo-Chung;Song Jun-Young;Park Moon-Sung;Kim Young-Soo;Pai Ki-Soo
    • Childhood Kidney Diseases
    • /
    • v.7 no.2
    • /
    • pp.181-188
    • /
    • 2003
  • Purpose : Vesicoureteral reflux(VUR) is known to be the main cause of childhood hypertension and renal failure. Knowing its familial occurrence, we determined the incidence of VUR and renal scar in asymptomatic siblings of Korean patients with primary VUR Methods : A total of 50 siblings from 37 index patients were included. Voiding cystourethro-graphy(VCUG) and renal scintigraphy using $^{99m}Tc-DMSA$ were peformed in these siblings from June, 1994 to May, 2001, Index patients were classified into two groups according to the presence of VUR in their siblings, and the clinical factors of the index patients such as age, sex, grade of reflux and renal cortical defect were compared between the groups. Results : Among the 50 siblings, VUR were found in 8(16%) and renal cortical defects were detected in 8(16%) siblings respectively. The incidence of renal cortical defects was 87.5%(7 out of 8) in the VUR(+) siblings. There was a case of VUR(-) cortical defect in one sibling, presumed as a scar from an old VUR. There was no relationship among age, sex, grade of reflux and renal cortical defect of the index patient to the presence of VUR in siblings. Conclusion : This study confirmed a significant incidence of VUR(16%) and renal cortical defects(16%) in the asymptomatic siblings of patients with primary VUR in Korea. It Is resonable to recommend screening studies to the siblings of patients with VUR for the early detection and prevention of probable reflux nephropathy. (J K orean Soc Pediatr Nephrol 2003;7:181-188)

  • PDF

The Epidemiological Study on the Cataract of the Rural Aged Population Using a Simplified Screening System (간편한 선별검사법에 의한 농촌 노인인구의 백내장에 대한 역학조사)

  • Park, Eun Kyoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.165-171
    • /
    • 2000
  • The purpose of this study is to determine the prevalence of cataracts in a rural area of Kyung-Buk province. Cataract is the main cause of blindness and visual impairment in the world. Recently, the number of age-related cataract surgeries has increased remarkably. In spite of such an increase in the number of patients, there are still many cataract patients with highly deteriorated visual function who have had no occasion to receive an ocular examination. In order to screen such patients the author assessed 636 individual(1272 eyes) aged 50 years or more who had wanted to be examined generally in two area. Chilgok and Munkyung, Kyung-Buk province using a simplified cataract screening system recently proposed by Sasaki et al. Kanazawa Medical University in Japan. The results obtained are as follows. The number of visual impairment patients in this study group was 493(77.5%). They were screened by cataract screening system. Primary screening examination detected 448 subjects to be suspected of cataract while the subsequent secondary examination narrowed this number of subjects to 308(48.4%). Final number of subjects to be diagnosed of cataract was 421(66.2%). The rate of incidence, according to the age, was 27.5% in the 50 year-olds age group, 62.5% in the 60's age group, 86.1% in the 70's age group and 94.3% in the 80's age group and upwards. This results concluded that cataract is the main cause of blindness and visual impairment and is an important public eye health care problem of aged population in rural Korea. Methods of tackling the cataract problem(both backlog and incident), and other eye health needs are recommended. The need to extend eye health service to the rural areas is emphasized.

  • PDF

Application of Low-Dose CT for Screening of Lung Disease (폐질환의 선별검사를 위한 저선량 전산화 단층촬영의 적용)

  • Lee, Won-Jeong;Choi, Byung-Soon;Park, Young-Sun;Seon, Jong-Ryul;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.129-140
    • /
    • 2009
  • As CT has been increasingly used as an accurate screening tool for lung disease, radiation dose becomes an important issue for both radiographers and patients. Many researches have been done for a low-dose CT as a screening tool for early detection of asymptomatic lung diseases. From those studies, it has been reported that chest dose rate from the low-dose CT is considerably lower than from standard CT. The patient dose is determined by scanning parameters such as kVp, mAs, pitch, scan time and the radiation risk of lung in screening examination may not be negligible. Herein, we suggest that Low-dose CT is useful as a screening tool in routine clinical practice on the basis of published articles, but further study is necessary because Low-dose CT has poor sensitivity and specificity for screening early stage of lung cancer according to the results of the studies. This article is to provide a brief overview of the screening examinations by Low-dose CT.

  • PDF