• Title/Summary/Keyword: 선박 갑판

Search Result 91, Processing Time 0.02 seconds

Noise Exposure Level Measurements for Different Job Categories on Ships (선박의 담당업무에 따른 소음노출레벨 측정에 관한 연구)

  • Im, Myeong-Hwan;Choe, Sang-Bom
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.875-882
    • /
    • 2021
  • To minimize occupational noise induced hearing loss, it is recommended that workers should not be exposed to noise levels exceeding 85 dBA for over 8 h. In the present study, noise exposure levels were measured for seven workers based on their tasks on a training ship. The A-weighted noise exposure level (Lex,24h) was measured by taking into account the A-weighted equivalent continuous sound level (LAeq,i), duration (h) and noise contribution (Lex,24h,i) from the workers' locations. Results are thus obtained for different job categories as follows: officer group Lex,24h=56.1 dB, navigation crew Lex,24h=58.9 dB, navigation cadet Lex,24h=62.0 dB, ship's cook Lex,24h=64.3 dB, engine cadet Lex,24h=91.1 dB, engineer Lex,24h=91.1 dB, and engine crew Lex,24h=95.1 dB. It was determined that the engineers, engine crews, and engine cadets in charge of machinery must wear hearing protection devices. By wearing hearing protection devices when working in highly noisy engine rooms, it is estimated that the noise expose levels could be reduced by the following amounts: engineer Lex,24h=23.1 dB, engine Crew Lex,24h=24.4 dB, and engine cadet Lex,24h=21.5 dB. Moreover, if the no. 2 lecture room and mess room bottom plates in the cadets accommodations were improved to the 64 mm A-60-class floating plates, then further reductions are possible as follows: navigation cadet Lex,24h=4.3 dB and engine cadet Lex,24h=1.8 dB.

Axial Collapse Behaviour of Ship's Stiffened Panels considering Lateral Pressure Load (횡하중을 고려한 선체보강판넬의 압축 붕괴거동에 관한 연구)

  • Ko, Jae-Yong;Park, Joo-Shin
    • Journal of Navigation and Port Research
    • /
    • v.31 no.3 s.119
    • /
    • pp.235-245
    • /
    • 2007
  • Stiffened steel plates are basic structural members on the deck and bottom structure in ship, offshore. It has a number of one sided stiffeners in either one or both directions, the latter structure was called grillage structure. At the ship structural desgn stage, one of the major consideration is evaluation for ultimate strength of the hull girder. In general, it is accepted that hull girder strength can be represented by the local strength of the longitudinal stiffened panel. In case of considering hogging condition in a stormy sea, stiffened panel was acting on the bottom structure under axial compressive load induced hull girder bending moment, also simultaneously arising local bending moment induced lateral pressure load. In this paper, results of the structural analysis have been compared with another detailed FEA program and prediction from design guideline and a series analysis was conducted consideration of changing parameters for instance, analysis range, cross-section of stiffener, web height and amplitude of lateral pressure load subjected to combined load (axial compression and lateral pressure load). It has been found that finite element modeling is capable of predicting the behaviour and ultimate load capacity of a simply supported stiffened plate subjected to combined load of axial compression and lateral pressure load It is expected that these results will be used to examine the effect of interaction between lateral pressure and axial loads for the ultimate load-carrying capacity based on the Ultimate Limit State design guideline.

Full-Scale Measurement of Pure Car Carrier (자동차 운반선에 대한 실선 계측)

  • Jin-S.,Park;Oi-H.,Kim;Zae-K.,Chung
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.1
    • /
    • pp.46-62
    • /
    • 1989
  • This paper presents the results of full-scale structural measurements of 4,800 unit pure car carriers "HYUNDAI NO.103" and "HYUNDAI NO.105" on one voyage respectively for each ship, especially in order to investigate the local strength of partial bulkhead above free-board deck. With the measured data, the short-term frequency analyses have been performed. The results show that the wave-induced stresses follow, on the whole, well the Rayleigh distribution. In addition, it has been found from the measured data that transverse local stresses at bulkhead section have a very close relation with the acceleration in athwartship direction. Finally, the long-term analysis has been attempted by using the following two statistical distributions mainly in order to estimate the maximum stress amplitude at the corners of partial bulkhead. 1) Exponential distribution of cycles of stress amplitude 2) Double exponential distribution of extreme values of stress amplitude for each short-term analysis The results of these two cases show a good agreement with each other. For example, the estimated maximum stress amplitude for 10 years at port-side corner of Fr. 132 partial bulkhead is $2125kg/cm^2$ for the first case and $2170kg/cm^2$ for the second case just based on the measured data.

  • PDF

Analysis of Grounding Accidents in Small Fishing Vessels and Suggestions to Reduce Them (소형어선의 좌초사고 분석과 사고 저감을 위한 제언)

  • Chong, Dae-Yul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.533-541
    • /
    • 2022
  • An analysis of marine accidents that occurred in the last five years, revealed that 77.0 % of all grounding accidents and 66.1% of all marine casualties involved small vessels, which was a very high level relatively. The Mokpo Regional Maritime Safety Tribunal (Mokpo-KMST) inquired on 72 cases of marine accidents in 2021, of which 10 cases were grounding accidents. Furthermore, eight cases of grounding accidents occurred in small fishing vessels. This study analyzed eight cases of grounding accidents on small fishing vessels that inquired in the jurisdictional area of Mokpo-KMST in 2021. I found out that this grounding occurred in clear weather with good visibility (2-4 miles) and good sea conditions with a wave height of less than 1 meter. Furthermore, I found that the main causes of grounding were drowsy navigation due to fatigue, neglect of vigilance, neglect of checking ship's position, overconfidence in GPS plotter, and lack of understanding of chart symbols and tidal differences. To reduce grounding accidents of small fishing vessels, I suggested the following measures. First, crew members who have completed the able seafarer training course on bridge watchkeeping should assist to the master. Second, alarm systems to prevent drowsiness should be installed in the bridge. Third, the regulation should be prepared for the performance standards and updating GPS plotter. Finally, the skipper of small vessels should be trained periodically to be familiar with chart symbols and basic terrestrial navigation.

Development of Rope Winding Device for Safety Fishing Operation of Small Trap Fishing Vessel (소형 통발어선의 안전조업을 위한 로프 권양장치 연구)

  • Kim, Dae-Jin;Jang, Duck-Jong;Park, Ju-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.19-29
    • /
    • 2022
  • The result of a questionnaire survey conducted on fishermen using coastal fish traps shows that fall accidents during trap dropping and pulling constitute the highest proportion of accidents at 42.1 %, whereas slipping accidents on the deck or stricture accidents to the body due to the trap winding device constitute 21.1 % each. In addition, 53.2 % of all surveyed subjects responded that trap pulling is the most dangerous task, followed by fish sorting 33.8 %, and trap dropping 9.1 %. As for the main items requested by fishermen for improving the trap winding device, 36.8 % indicated a method to easily lift the trap from the water to the work deck, and 31.6 % indicated a method to overcome the rope tension and prevent slip when pulling the trap to reduce the accidents. The small trap fishing vessel winding device proposed herein can increase the winding force by strengthening the rope contact area and friction coefficient via an appropriate contact angle between the driving roller of the winding device and the rope. When the contact angles between the driving roller and the rope are 1°, 5°, 9°, 14° and 19°, the rope tension showed a difference according to each contact angle. When the contact angle is 9°, the rope tension is the highest at 392.62 kgf. Based on these experimental results, a prototype winding device is manufactured, and 25 traps are installed on a rope with a total length of 100 m at 4 m intervals in the sea, and then the rope tension is measured during trap pulling. As a result, the rope tension increases rapidly at the initial stage of trap pulling and shows the highest value of 31.89 kgf, which subsequently decreases significantly. Therefore, it is appropriate to design the winding force of a small trap fishing vessel winding device based on the maximum tension value of the rope specified at the beginning of the trap pulling operation.

A Study on the Structural Reinforcement of the Modified Caisson Floating Dock (개조된 케이슨 플로팅 도크의 구조 보강에 대한 연구)

  • Kim, Hong-Jo;Seo, Kwang-Cheol;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.172-178
    • /
    • 2021
  • In the ship repair market, interest in maintenance and repair is steadily increasing due to the reinforcement of prevention of environmental pollution caused by ships and the reinforcement of safety standards for ship structures. By reflecting this effect, the number of requests for repairs by foreign shipping companies increases to repair shipbuilders in the Southwest Sea. However, because most of the repair shipbuilders in the southwestern area are small and medium-sized companies, it is difficult to lead to the integrated synergy effect of the repair shipbuilding companies. Moreover, the infrastructure is not integrated; hence, using the infrastructure jointly is a challenge, which acts as an obstacle to the activation of the repair shipbuilding industry. Floating docks are indispensable to operating the repair shipbuilding business; in addition, most of them are operated through renovation/repair after importing aging caisson docks from overseas. However, their service life is more than 30 years; additionally, there is no structure inspection standard. Therefore, it is vulnerable to the safety field. In this study, the finite element analysis program of ANSYS was used to evaluate the structural safety of the modified caisson dock and obtain additional structural reinforcement schemes to solve the derived problems. For the floating docks, there are classification regulations; however, concerning structural strength, the regulations are insufficient, and the applicability is inferior. These insufficient evaluation areas were supplemented through a detailed structural FE-analysis. The reinforcement plan was decided by reinforcing the pontoon deck and reinforcement of the side tank, considering the characteristics of the repair shipyard condition. The final plan was selected to reinforce the side wing tank through the structural analysis of the decision; in addition, the actual structure was fabricated to reflect the reinforcement plan. Our results can be used as reference data for improving the structural strength of similar facilities; we believe that the optimal solution can be found quickly if this method is used during renovation/repair.

Characteristic of Buckling and Ultimate Strength of the Perforated Stiffened Plate (유공보강판의 좌굴 및 극한강도 특성에 관한 연구)

  • Park Joo-Shin;Ko Jae-Yong;Oh Kyoung-Gun
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.439-446
    • /
    • 2006
  • In ship structures many of the structural plates have cutouts, for example, at inner bottom structure, girder, upper deck hatch, floor and dia-frame etc. In the case where a plate has a cutout it experiences reduced buckling and ultimate strength and at the same time the in-plane stress under compressive load produced by hull girder bending will be redistributed In general, actual ship structure adopted reinforcement of stiffener around the cutout in order to preventing from buckling so it need to examine a buckling and ultimate strength behaviour considering a cutout because In many ship yards used class rule for calculating buckling strength but it is difficult to evaluate perforate stiffened plate with random size. In the present paper, we investigated several kinds of perforated stiffened model from actual ship and then was performed finite element series analysis varying the cutout ratio, web height, thickness and type of cross-section using commercial FEA program(ANSYS) under compressive load.

Development of Designed Formulae for Predicting Ultimate Strength of the Perforated Stiffened Plate subjected to Axial Compressive Loading (압축하중을 받는 유공보강판 구조의 최종강도 설계식 개발)

  • Park, Joo-Shin;Ko, Jae-Yong;Lee, Kyung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.435-445
    • /
    • 2007
  • Ship structures are thin-walled structures and lots of cutouts, for example, of inner bottom structure, girder, upper deck hatch, floor and dia-frame etc. In the case where a plate has cutout it experiences reduced buckling and ultimate strength and at the same time the in-plane stress under compressive load produced by hull girder bending will be redistributed. In the present paper, we investigated several kinds of perforated stiffened model from actual ship structure and series of elasto-plastic large deflection analyses were performed to investigate into the influence of perforation on the buckling and ultimate strength of the perforated stiffened plate varying the cutout ratio, web height, thickness and type of cross-section by commercial FEA program(ANSYS). Closed-form formulas for predicting the ultimate strength of the perforated stiffened plate are empirically derived by curve fitting based on the Finite Element Analysis results. These formulas are used to evaluate the ultimate strength, which showed good correlation with FEM results. These results will be useful for evaluating the ultimate strength of the perforated stiffened plate in the preliminary design.

A Study on the Ultimate Strength Behavior for Ship Perforated Stiffened Plate (선체 유공보강판의 최종강도 거동에 관한 연구)

  • Ko Jae-Yong;Lee Jun-Kyo;Park Joo-Shin;Bae Dong-Kyun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.141-146
    • /
    • 2005
  • Ship have cutout inner bottom and girder and floor etc. Ship's structure is used much, and structure strength must be situated, but establish new concept when high stress interacts sometimes fatally the area. There is no big problem usually by aim of weight reduction, a person and change of freight, piping etc. Because cutout's existence grow up in this place, and, elastic buckling strength by load causes large effect in ultimate strength. Therefore, stiffened perforated plate considering buckling strength and ultimate strength is one of important design criteria which must examine when decide structural concept at initial design. Therefore, and, reasonable buckling strength about perforated stiffened plate need to ultimate strength limited design . Calculated ultimate strength varied several web height and cutout's dimension, and thickness in this investigated data. Used program(ANSYS) applied F.E.A code based on finite element method.

  • PDF

Structure Design Sensitivity Analysis of Active Type DSF for Offshore Plant Float-over Installation Using Design of Experiments (실험계획법을 이용한 해양플랜트 플로트오버 설치 작업용 능동형 DSF의 구조설계 민감도 해석)

  • Kim, Hun-Gwan;Song, Chang Yong;Lee, Kangsu
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.98-106
    • /
    • 2021
  • The paper deals with comparative study on sensitivity analysis using various methods regarding to design of experiments for structure design of an active type DSF (Deck support frame) that was developed for float-over installation of offshore plant. The thickness sizing variables of structure member of the active type DSF were considered the design factors. The output responses were defined from the weight and the strength performances. Various methods such as orthogonal array design, Box-Behnken design, and Latin hypercube design were applied to the comparative study. In order to evaluate the approximation performance of the design space exploration according to the design of experiments, response surface method was generated for each design of experiment, and the accuracy characteristics of the approximation were reviewed. The design enhancement results such as numerical costs, weight minimization, etc. via the design of experiment methods were compared to the results of the best design. The orthogonal array design method represented the most improved results for the structure design of the active type DSF.