• Title/Summary/Keyword: 선량 분포 변화

Search Result 235, Processing Time 0.029 seconds

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

LINAC-based Stereotactic Radiosurgery for Meningiomas (수막종에 대한 선형가속기형 정위방사선수술)

  • Shin Seong Soo;Kim Dae Yong;Ahn Yong Chan;Lee Jung Il;Nam Do-Hyun;Lim Do Hoon;Huh Seung Jae;Yeo Inhwan J;Shin Hyung Jin;Park Kwan;Kim BoKyoung;Kim Jong Hyun
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.87-94
    • /
    • 2001
  • Purpose : To evaluate the role of LINAC-based stereotactic radiosurgery (SRS) in the management of meningiomas, we reviewed clinical response, image response, neurological deficits for patients treated at our institution. Methods and materials : Between February 1995 and December 1999, twenty-six patients were treated with SRS. Seven patients had undergone prior resection. Nineteen patients received SRS as the initial treatment. There were 7 male and 19 female patients. The median age was 51 years (range, $14\~67\;years$). At least one clinical symptom presented at the time of SRS in 17 patients and cranial neuropathy was seen in 7 patients. The median tumor volume was $4.7\;cm^3\;(range,\;0.7\~16.5\;m^3)$. The mean marginal dose was 15 Gy (range, $10\~20\;Gy$), delivered to the $80\%$ isodose surface (range, $46\~90\%$). The median clinical and imaging follow-up periods were 27 months (range, 1-71 months) and 25 months (range, $1\~52\;months$), respectively. Results : Of 14 patients who had clinical follow-up of one year or longer, thirteen patients $(93\%)$ were improved clinically at follow-up examination. Clinical symptom worsened in one patient at 4 months after SRS as a result of intratumoral edema, who underwent surgical resection at 7 months. OF 14 patients who had radiologic follow-up of one year or longer, tumor volume decreased in 7 patients $(50\%)$ at a median of 11 months (range, $6\~25\;months$), remained stable in 6 patients $(43\%)$, and increased in one patient $(7\%)$, who underwent surgical resection at 44 months. New radiation-induced neurological deficits developed in six patients $(23\%)$. Five patients $(19\%)$ had transient neurological deficits, completely resolved by conservative treatment including steroid therapy. Radiation-induced brain necrosis developed in one patient $(3.8\%)$ at 9 months after SRS who followed by surgical resection of tumor and necrotic tissue. Conclusions : LINAC-based SRS proves to be an effective and safe management strategy for small to moderate sized meningiomas, inoperable, residual, and recurrent, but long-term follow-up will be necessary to fully evaluate its efficacy. To reduce the radiation-induced neurological deficit for large size meningioma and/or in the proximity of critical and neural structure, more delicate treatment planning and optimal decision of radiation dose will be necessary.

  • PDF

Change of FDG Uptake According to Radiation Dose on Squamous Cell Carcinoma of the Head and Neck (두경부종양에서 방사선조사량에 타른 FDG-PET의 변화양상)

  • Lee Sang-wook;Kim Jae-Seung;Im Ki Chun;Ryu Jin Sook;Lee Hee Kwan;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Yoon Sang Min;Song Siyeol;Park Jin-hong;Moon Dae Hyuk;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.98-105
    • /
    • 2004
  • Purpose : To evaluate whether positron omission tomography (PET) with 2-[F-18]fluoro-2-deoxy-D-giucose(FDG) can be used to predict of early response to definitive aim radlotherapy (RT) in squamous cell carcinoma of the head and neck using response rate and locoreglonal control as study endpoints. Materials and Methods : Twenty-two patients with head and neck cancer underwent a FDG-PET study before RT, after a flrst dose of 45 Gy, and after a second dose on more 4han 70 Gy. Standard uptake value (SUV) was calculated for primary tumor (n=22) and neck lymph node (n:10). Attenuation corrected PET scans acquired 60 min after tracer injection were used for evaluation of FDG uptake In tumors. A quantitative FDG uptake index was expressed as Suvlean (corrected for iean body mass). The follow-up time was at least 5 months (range S-1 S months). Results : A total of 22 primary tumors and 10 metastatic lymph nodes were analyzed In FDG-PET. In the first PET study the mean SUVlean the primary tumors and nodes were 5.4 (SD, 2.5) and 4.6 (SD, 2.3), respectively. In the second PET, study peformed after 46 Gy RT the mean SUV in primary tumor and node decreased to 2.9 (SD, 1.9, p<0.001) and 1.7 (SD, 1.3) respectively. in the third PET study peformed at the full dose (more than 70 Gy), RT the mean SUV In the primary tumors and nodes decreased to 2.3 (SD, 1.5, p<0.001) and 1.5 (SD, 1 .1) respectively. Conclusions: FDG uptake In tumors showed a significant decrease after the 45 Gy and more than 70 Gy of RT for squamous cell carcinoma of the head and neck. Reduction of metabolic activity after 46 Gy of radiotherapy Is closely correlated with radiation response.

Studies on the Changes of Lipids during Soybean Koji Preparation for Daenjang Fermentation in Model System (된장 발효(醱酵) 중 콩 Koji 제조(製造)과정에 있어서 지질성분(脂質成分)의 변화(變化)에 관한 연구(硏究))

  • Lee, Sook-Hee;Cheigh, Hong-Sik;Kim, Chang-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.375-381
    • /
    • 1982
  • The studies are conducted on the changes of soybean lipids in terms of physicochemical characteristics, lipid classess and fatty acid composition during the fermentation process of soybean Koji preparation for daenjang (soybean paste) in a model system using cooked soybean inoculated by Aspergillus oryzae. The total lipids contents were increased during soybean Koji preparation, generally iodine values decreased but acid values increased. Total lipids of soybean Koji consisted of about 90.6% neutral lipids, 7.6% phospholipids and 1.8%, glycolipids indicating that phospholipids contents of soybean Koji was increased when compared to those of cooked soybean. The major components of nonpolar lipids in soybean Koji were free fatty acids(39.6%) and triglycerids(29.2%). Free fatty acids increased as the triglycerides decreased during soybean Koji preparation by the hydrolysis of lipase action. The major components of polar lipids in soybean Koji were phosphatidyl choline and phosphatidyl ethanolamine. Differences were observed in the composition of the polar lipids of cooked soybean and soybean Koji. A little changes also occurred in fatty acid compositions of total lipids, triglycerides and free fatty acids fractions in soybean Koji preparation. Especially a considerable increase of linoleic acid in free fatty acid fraction was observed in soybean Koji.

  • PDF

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF