• Title/Summary/Keyword: 선량한도 하향

Search Result 3, Processing Time 0.016 seconds

Estimated Additional Number of Workers and Additional Collective Dose by Reducing Dose Limits (선량한도 하향이 방사선작업인력 및 집단선량에 미치는 영향예측)

  • Ha, Chung-Woo;Na, Seong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.149-157
    • /
    • 1998
  • An analysis has been performed to estimate the additional number of workers and the additional collective dose in man-cSv which would be required, nuclear industry-wide as a result of reducing individual dose limit. This analysis can be extended to the reduction in the dose limits recommended by ICRP Publ.60 and BEIR V report as well as the proposed dose limits by regulatory authorities. An industry-wide database was employed in the analysis based on a summary of industry-wide occupational radiation exposure compiled by the Korea Radioisotope Association. Correlation model was employed to compute the affects of setting specific annual individual dose limits. In this study, we have addressed worker non-productivity while in the radiation environment on a parametric or 'sensitivity analysis' basis. This alleviates the need for developing such data underlying a summation of many individual tasks at many nuclear facilities. It has the advantage that very low non-productivity assumptions can readily be defended as conservative, in that it is difficult to approach such low worker non-productivity factors even in the best of environments in any industry. On a per facility basis, for calendar year 1997, the number of workers required would be increased from 231 workers to 269 workers and collective man-cSv dose would be also increased by approximately fourteen percent if the individual dose limit was reduced to 2 cSv/y and an individual worker non-productivity fraction of 0.1 is assumed.

  • PDF

A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD (다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구)

  • Lee, Na-Rae;Han, Seung-Jae;Lee, Byung-Il;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.

An Optimization Study on the Radiation Management in Nuclear Power Plants (원자력 발전소 방사선 관리의 최적화에 관한 연구)

  • Song, Jong-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.71-82
    • /
    • 1993
  • It is a fundamental element of the nuclear power plant operation to assess exactly the occupational radiation exposure. And, according to recently published ICRP 60 recommendation, it is needed to reduce individual radiaton exposure limit further. In this paper, an optimization techique was suggested for selection of alternatives for reducing occupational radiation exposure, and used in reviewing alternatives given by a plant utility. After the basic analysis, sensitivity analysis was performed to consider the variabilities of the economic variables. From the result, it was found that an option using steam generator nozzle dam and torquing machine was the best with respect to total benefits, and in case of multi-attribute utility analysis, an option using Co-No seal had the highest utility. Therefore, it was necessary to apply more than one technique togeter in optimization study and to consider qualitative factor, too.

  • PDF