Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

Evaluation of Bolus Applicability through Dose Evaluation According to 3D Print Materials (3D 프린트 소재에 따른 선량평가를 통한 볼루스 적용성 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.241-246
    • /
    • 2019
  • Among the 4th Industrial Revolution technologies, evaluated bolus applicability through dose assesment according to the materials of 3D printing technology. Dose assesment was using MCNPX which was applied Monte Carlo method and 3D print materials were ABS, PC and PLA. Thus, the thickness with the same effect as the bolus 10 mm was found to be ABS 10 mm, PC 9 mm and PLA 9 mm for the 6 MeV electron. For 6 MV X-ray, ABS 11 mm, PC 10 mm and PLA 9 mm were shown. This study showed that tissue equivalent materials made from 3D printer materials can replace bolus.

The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy (방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구)

  • Yang, Seung-Woo;Han, Moo-Jae;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.789-794
    • /
    • 2021
  • Brachytherapy is a treatment in which radioactive isotopes are placed inside the body to intensively irradiate the tumor with radiation. Because brachytherapy uses a radioisotope source with a high dose rate, it is very important to know the exact location and dose of the source. However, in clinical practice, it is evaluated inaccurately with the naked eye through rulers and autoradiographs. Therefore, in this study, a dosimeter that can be used for brachytherapy was developed using a lead(II) iodide (PbI2) material, and the applicability was evaluated by analyzing the reproducibility, linearity, and PID items. As a result of reproducibility evaluation, the RSD value was 1.41%, satisfying the evaluation criteria of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the evaluation criterion of 0.9990. As a result of PID evaluation, it showed only a difference of 0.06 cm compared with the theoretical value of the inverse square law of distance at the 50% dose reduction point. The dosimeter manufactured in this experiment shows results that satisfy the standard in all evaluations, so it is judged that the possibility of applying the dosimeter in the radiation brachytherapy area is sufficient.

Development of 2.5D Photon Dose Calculation Algorithm (2.5D 광자선 선량계산 알고리즘 개발)

  • 조병철;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.103-114
    • /
    • 1999
  • In this study, as a preliminary study for developing a full 3D photon dose calculation algorithm, We developed 2.5D photon dose calculation algorithm by extending 2D calculation algorithm to allow non-coplanar configurations of photon beams. For this purpose, we defined the 3d patient coordinate system and the 3d beam coordinate system, which are appropriate to 3d treatment planning and dose calculation. and then, calculate a transformation matrix between them. For dose calculation, we extended 2d "Clarkson-Cunningham" model to 3d one, which can calculate wedge fields as well as regular and irregular fields on arbitrary plane. The simple Batho's power-law method was implemented as an inhomogeneity correction. We evaluated the accuracy of our dose model following procedures of AAPM TG#23; radiation treatment planning dosimetry verifications for 4MV of Varian Clinac-4. As results, PDDs (percent depth dose) of cubic fields, the accuracy of calculation are within 1% except buildup region, and $\pm$3% for irregular fields and wedge fields. And for 45$^{\circ}$ oblique incident beam, the deviations between measurements and calculations are within $\pm$4%. In the case of inhomogeneity correction, the calculation underestimate 7% at the lung/water boundary and overestimate 3% at the bone/water boundary. At the conclusions, we found out our model can predict dose with 5% accuracy at the general condition. we expect our model can be used as a tool for educational and research purpose.. purpose..

  • PDF

원자력시설의 정상운영시 주민피폭선량평가 입력자료의 개선

  • 전제근;이관희
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.437-438
    • /
    • 2004
  • 원자력시설의 정상운영시 방사성물질이 기체 및 액체상의 형태로 소외로 배출되며, 일정기간별로 배출된 핵종별 총량을 이용하여 주민피폭선량 평가를 수행함으로써 규제요건의 준수 여부를 확인한다. 이러한 원자력시설 주변 주민피폭선량평가에 적용되고 있는 주요 입력자료인 음식물섭취자료 등은 1988년 원자력연구소의 현장조사, 실험, 문헌조사 등을 통하여 결정되었으나 시간이 지남에 따라 일부자료의 경우 최신경향을 반영할 수 있도록 개정이 요구된다.(중략)

  • PDF

Dose Assessment during Pregnancy in Abdominal X-ray Examinations (복부 진단 X선 검사 시 태아 및 임산부의 선량 평가)

  • Woo, Ri-Won;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.261-270
    • /
    • 2020
  • In diagnostic X-ray examinations, dose assessments for pregnant female and fetus are realistically difficult, and related research is also lacking. Therefore, in this study, the purpose of the simulation was to analyze the dose and fetal dose for pregnant female during abdominal X-ray examination. Based on the data presented in ICRP 89, this study produced phantom reconstructed of the existing prenatal phantom, which was used to analyze the evaluation of the organ dose and fetal dose of pregnant female according to pregnancy week and the difference between the dose of the existing phantom and the reconstructed phantom. As a result, the abdominal X-ray test showed a tendency to show higher doses for organs close to the direction of the source joining. In addition, it was confirmed that fetal doses in posteroanterior position were reduced by more than 65% compared with anteroposterior position.

Dose Assessment during Pregnancy in Chest PA Examination (흉부 후전방향 검사 시 임산부의 선량 평가)

  • Woo, Ri-Won;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.661-668
    • /
    • 2020
  • One of the causes of death for pregnant female is embolism, when a chest PA examination is performed. In addition, due to small doses, the examinations are performed for the purpose of preparing for pre-delivery emergency surgery or basic examination for pregnant female. Evaluating fetal doses through actual measurements is subject to ethical problems, Monte Carlo simulations assesses the organ and fetal doses of pregnant females according to week of pregnancy. The results of the simulations showed that the fetal dose decreased according to weeks of pregnancy and it showed a dose of about 0.1 mGy. The higher the density and thickness of the shielding material, the better the shielding effect. In addition, the dose reduction effect for each shielding material is between 40 and 98%. Afterwards, it is deemed necessary to study the reduction of fetal doses through various shielding characteristics and methods.

Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study (토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험)

  • Dae-Gun, Kim;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.857-862
    • /
    • 2022
  • The purpose of this study was to evaluate a three-dimensional conformal radiotherapy (3D-CRT) treatment plan with regard to head tilting in whole-brain radiotherapy (WBRT) using TomoDirect (TD) mode in Tomotherapy. WBRT 3D-CRT by TD was compared for a total of five head tilt angles (-20°, -10°, 0°. +10° and +20°). The dose homogeneity index (HI) and prescription dose index (CI) were calculated to confirm the target coverage. The maximum and average doses for critical organs such as the lens, eyeball and parotid glands were calculated for different angles of head tilting. The HI and CI were closet to the result value of 1 at the head tilted angle +10° and +20°. At a head tilted angle of +10°, the dose to the lens and eyeballs decreased by about 74% and about 30%, when compared with the reference angle (0°), respectively. The results of this study suggest that a head angle of +10 with chin-up would save adequate target coverage and reduce exposure dose to the lens.

두경부암의 6MV 광자선 치료 시 표면선량 증가를 위한 Spoiler의 유용성 평가

  • 이강혁;김원택;이화중;김대영
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.41-47
    • /
    • 2002
  • 1.목적 두경부암(head and neck Ca)과 쇄골상부(Supraclavicular)에 6MV 광자선으로 치료 시 치료부위(Target volume)가 피부에서 대략 $1^{\sim}2mm$정도 깊이에 위치할 경우, 6MV 광자선의 선량분포는 표면선량이 낮아서 치료에 적합하지 않기 때문에 Bolus와 같이 사용하지만 Skin Sparing(피부보호)효과의 손실로 피부의 손상이 발생할 수 있다. 이러한 이유로 피부의 보호와 치료 시 표면선량의 증가를 위해 Spoiler(산란판)를 제작하여 측정 후 그 특성을 이해하고 선량의 분포를 통하여 Bolus와 비교한 후에 Spoiler의 유용성에 대해 평가하고자 하였다. 2.방법 Siemens사 선형가속기(PRIMUS)의 6MV 광자선을 사용하여 Spoiler의 사용여부 및 Spoiler의 사용 시에는 조사면의 크기를 $5{\times}5,\;7{\times}7,\;10{\times}10,\;15{\times}15,\;20{\times}20cm^2$로 하고 Spoiler와 표면과의 거리는 6, 10, 15cm로 바꾸어 가면서 물팬톰(PTW. 독일)을 이용해 깊이와 측방에 따른 선량분포를 Markus 전리함(PTW. 독일)으로 측정하였으며 전리함의 방수를 위해 씌어진 방수 캡 때문에 표면선량을 별도의 고형 팬톰으로 측정하였다. 표면의 측정선량은 전리함의 측면 벽 등에 의한 선량 측정치의 증가 현상으로 과 반응을 보였으며 이를 교정하였다. 그리고 측정된 데이터를 치료계획 시스템(Pinnacle 6.0m)으로 비교, 분석하였다. 3.결과 Spoiler의 사용 시 3cm깊이 측정선량 백분율과 Spoiler를 사용하지 않은 해당 치료 조사면의 3cm깊이 선량의 백분율에 일치하도록 하여 가상의 치료 깊이인 2mm에서 측정값을 비교하여 본 결과 조사면 $5{\times}5,\;10{\times}10,\;20{\times}20cm^2$에서 OPEN시 62, 64, $70\%$, Bolus는 97, 97, $99\%$로 Spoiler의 사용 시 표면과의 거리가 6cm에서 82, 98, $103\%$, 10cm에는 72, 89, $101\%$, 15m에 65, 79, $96\%$로 나타났으며 표면에서의 측정값을 비교하여 본 결과 OPEN시 11, 17, $27\%$, Bolus는 84, 84, $86\%$, Spoiler의 사용 시 6cm에서 40, 71, $93\%$, 10cm에는 25, 50, $81\%$, 15cm에 18, 36, $67\%$를 나타내었다. 또한 3m깊이에서의 측방 선량분포에서 Spoiler의 거리변화(6, 10cm)는 심부선량의 변화에 영향을 주지 않는 것으로 확인할 수 있었다. 그리고 위의 실험측정치를 치료계획 시스템에 입력하여 선량분포를 확인한 결과 Spoiler를 사용하는 경우 OPEN에 비해 선량분포 영역을 표면으로 끌어 올릴 수 있으며 Bolus 보다 피부 보호효과는 어느 정도 유지가 되는 것을 보여주었다. 4.결론 이와 같이 Spoiler는 Bolus와 비교하여 6MV 광자선의 build up 영역을 표면으로 증가시키는 동시에 Skin Sparing(피부보호)효과를 유지할 수 있으며 두경부암의 치료에서 Spoiler의 사용이 가능한 조건으로는 조사면이 $5{\times}5cm^2$에서 Spoiler와 표면과의 거리가 6cm일 때, $7{\times}7cm^2$에서 6cm, 10cm였고 $10{\times}10cm^2$는 10cm, 15cm로, $15{\times}15cm^2$는 15cm의 간격으로 평가되었다. 또한 $20{\times}20cm^2$의 조사면, Spoiler가 6cm 간격 인 경우 Bolus를 사용한 것 보다 더욱 높은 표면선량을 나타내었다. 그러나 Spoiler와 표면간의 거리를 다르게 함으로써 깊이에 따라 선량분포를 다양하게 나타낼 수 있기 때문에 표면선량의 증가와 피부의 보호를 위해 환자의 피부 두께, 실제 치료 부위의 깊이 등을 고려한다면 Spoiler를 사용하는 것이 bolus를 사용하는 것보다 더 유용하게 적용할 수 있을 것으로 사료된다.

  • PDF