• Title/Summary/Keyword: 선계산

Search Result 2,319, Processing Time 0.03 seconds

Load Balanced QoS Routing for Precomputation of QoS Routes (QoS 경로의 선계산을 적용한 부하분산 QoS 라우팅)

  • 홍종준
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.1
    • /
    • pp.121-127
    • /
    • 2003
  • In this paper, we propose a load balancing QoS routing on a targe scale network. We use the scheme in which it calculates the cost of resources with a precomputation and then selects a path among multiple paths based on the calculated cost for each resources. We also use the QoS routing scheme for the transit and the intra-traffic on a large scale domain-based network. For a domain in networks, this routing scheme precomputes K multiple paths between all pairs made up with each ingress and egress border routers along with the consideration of a load balancing, and then picks up paths having the high probability on the Path selection. This routing scheme can be applied for the transit traffic and the intra traffic and combines the Inter-domain and intra-domain routings seamlessly and put a high priority on the transit traffic Thus, these schemes make Possible both the global use of network resources and the load balancing.

  • PDF

The Comparison of the Calculations for the Lightning Outage Hate of Transmission Line Using the EPRI-Flash program and CRIEPI-LORP Program (EPRI-FLASH 및 CRIEPI-LORP를 이용한 송전선로의 뇌사고율 예측계산 비교)

  • Kang, Y.W.;Kwak, J.S.;Woo, J.W.;Kweon, D.J.;Shim, E.B.;Jung, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1635-1637
    • /
    • 2003
  • 송전선의 뇌사고율은 뇌방전 현상, 송전선의 써지 전달 현상, 아킹혼 사이의 섬락 현상 등 다양한 현상이 관련된다. 송전선의 내뢰설계 목표는 이러한 자연현상 및 물리적인 현상이 편차를 포함하고 있다는 것을 인식하고, 가능한 한 정확도가 높은 뇌사고율을 예측을 수행하고 허용 가능한 뇌사고율을 산정하여 송전선로 설계시 반영하는 것이다. 이러한 예측 계산을 위해 한전에서는 EPRI에서 개발한 FLASH 프로그램을 기본으로 사용해 왔으며, 이 예측계산법의 타당성은 예측 사고율과 사고 실적과의 비교에 의해 검토되어야 한다. 한전에서는 과거 10년간의 뇌사고 실적과 FLASH 프로그램으로 계산한 예측 사고율이 차이가 많이 나타나고 있어, FLASH 프로그램의 예측 계산법의 타당성에 의문을 제기하고 있는 상황이다. 일본 전력회사들은 뇌사고율을 예측 계산하기 위하여 1988년에 전력중앙연구소에서 개발한 프로그램을 사용하여 왔으며, 최근에 사고 실적과의 비교 및 관련 연구를 수행하여 예측 계산 프로그램에 사용되는 파라메타를 수정 보완한 LORP2000-1을 완성하였다. 본 논문에서는 지리, 기후적으로 한국과 유사한 일본의 자연현상을 반영한 LORP 프로그램의 예측계산법이 한전 송전선로의 뇌사고율 예측 계산에 적용 가능성을 사고 실적과의 비교를 통해 검토하였다.

  • PDF

Calculation of Telluric Absorbtion Spectra

  • Jeong, Gwanghui;Han, Inwoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.82.2-82.2
    • /
    • 2014
  • 지상에서 천체 분광관측을 하면 천체 스펙트럼에 대기 흡수선이 겹쳐 나타나기 때문에 이를 제거해주어야 한다. 대기 흡수선은 주로 적외선 영역에 많이 나타나고, 주로 H2O, O2, CO2, O3, CH4 등의 분자에 의하여 생긴다. 대기 흡수선을 제거하기 위하여 조기형 별을 관측하여 그 스펙트럼으로 천체스펙트럼을 나누어주는 방법이 널리 이용된다. 본 연구에서는 인공 흡수선 스펙트럼을 계산하여 대기 흡수선을 제거하는 방법을 소개하기로 한다. 인공 흡수선 스펙트럼 계산은 LBLRTM 코드를 이용하였으며 대기모델은 MIPAS를 채택하였다. 이렇게 계산한 인공 스펙트럼을 실제 관측된 대기 흡수선에 맞추기 위하여 가우시안 라인 프로파일을 이용하고 파장 눈금을 조정해 준다. 이 과정에서 대기 흡수선을 정밀 시선속도 측정을 위한 파장 표준으로 이용할 수 있다.

  • PDF

The Calculation of Energy Distributions for Clinical Electron Beams from Mono Energetic Depth dose Data (단일에너지 깊이선량률 자료에 의한 치료용 전자선의 에너지분포 계산)

  • 이정옥;정동혁
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 2004
  • The energy distributions for clinically used electron beams from measured and calculated mono energetic depth dose values were calculated. The energy distributions having the minimum difference between the measured and reduced values of depth dose are determined by iterations based on least square method. The nominal energies of 6, 9, 12, 15 MeV clinical electron beams were examined. The Monte Carlo depth dose calculations with determined energy distributions were peformed to evaluate those distributions. In a comparison of the calculated and measured depth dose data, the standard errors are estimated within $\pm$ 3% from surface to R$_{80}$ depth and within $\pm$4% from the surface to near the range for all electron beams. This can be practically applied to determine the energy distributions for clinically used electron beams.

  • PDF

Development of the Simulator for Induced Voltage Calculation to a Communication Line from a Power Transmission Line (송전선 상시 운전 시 통신선 유도전압 계산 시뮬레이터 개발)

  • Han, Woong;Kwon, O.S.;Heo, J.Y.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.278-279
    • /
    • 2006
  • 본 논문에서는 송전선 상시 운전 시 통신선에 미치는 유도전압 계산 시뮬레이터를 개발하였다. 본 시뮬레이터는 Visual C++를 이용하여 개발되었으며, 송전탑 및 도선의 데이터들을 입력함으로써 통신선 유도전압을 계산할 수 있다. 또한, 본 시뮬레이터는 EMTP 프로그램을 내장하여 동작하며 GUI 방식으로 설계되어 보다 손쉽게 유도전압을 계산할 수 있다.

  • PDF

Comparison of Monitor Units Obtained from Measurements and ADAC Planning System for High Energy Electrons (측정과 ADAC 치료계획 시스템에서 계산된 고에너지 전자선의 Monitor Unit Value 비교)

  • Lee, Re-Na;Choi, Jin-Ho;Suh, Hyun-Suk
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.202-208
    • /
    • 2002
  • The purpose of this study is to evaluate the monitor unit obtained from various methods for the treatment of superficial cancers using electron beams. Thirty-three breast cancer patients who were treated in our institution with 6, 9, and 12 MeV electron beams, were selected for this study. For each patient, irregularly shaped treatment blocks were drawn on simulation film and constructed. Using the irregular blocks, monitor units to deliver 100 cGy to the dose maximum (dmax) were calculated from measurement and three-dimensional radiation treatment planning (3D RTP) system (PINNACLE 6.0, ADAC Laboratories, Milpitas CA) Measurements were made in solid water phantom with plane parallel (PP) chamber (Roos, OTW Germany) at 100 cm source-to surface distances. CT data was used to investigate the effect of heterogeneity. Monitor units were calculated by overriding CT values with 1 g/㎤ and in the presence of heterogeneity. The monitor unit values obtained by the above methods were compared. The dose, obtained from measurement in solid water phantom was higher than that of RTP values for irregularly shaped blocks. The maximum differences between monitor unit calculated in flat water phantom at gantry zero position were 4% for 6 MeV and 2% for 9 and 12 MeV electrons. When CT data was used at a various gantry angle the agreement between the TPS data with and without density correction was within 3% for all energies. These results indicate that there are no significant difference in terms of monitor unit when density is corrected for the treatment of breast cancer patients with electrons.

  • PDF

Calculation of Ground Fault Current considering Optional Increase of Power System Capacity (계통확장을 고려한 송전선로 1선지락 고장전류의 계산)

  • Choi, Jong-Kee;Shin, Bok-Hyun;Kim, Jae-Joon;Kim, Tai-Young;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.659-660
    • /
    • 2007
  • 전력계통의 고장계산에는 상호 결합된 삼상회로를 결합이 없는 단상회로 3개, 즉 영상, 정상, 역상의 대칭요소로 변환하여 해석하는 대칭좌표법이 널리 사용되고 있다. PSS/E는 국내 전력회사에서 고장 계산을 위해 널리 사용되어온 상용 프로그램이며, 고장계산 결과는 차단기 등 각종 기기의 정격의 결정 등에 이용된다. 특수한 경우에 지락사고 해석시 과도한 안전여유를 고려하는 것이 필요한 경우가 있다. 본 논문에서는 송전선로 지락시 등가 전원단 용량이 임의로 증가했을 때에 송전선로 중간의 임의 지점의 지락고장전류를 계산하는 수식을 유도하였으며, PSS/E 계산값과의 비교를 통해 계산방법의 신뢰성을 검증하였다.

  • PDF

Calculation of Electro-Magnetic Interference and Countermeasures (전력선 유도장해 예측계산법과 대책)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.38-42
    • /
    • 2001
  • 우리나라는 1968년 이후에 154kV급 송전 계통망을 비접지 방식에서 직접 접지방식으로 변경함에 따라, 전력선의 1선 지락고장시 송전선으로부터 지락전류 즉, 고장전류가 크게 되어 이 결과 송전선 주변에 있는 통신선에 유도문제가 발생하게 되었다. 본 논문에서는 전력선에 의한 통신선측의 유도전압 예측계산식을 제시하고, 유도예측 계산치가 일정 기준을 초과할 경우, 통신선측과 전력선측에서 강구할 수 있는 대책방안에 대해 소개하고자 한다.

  • PDF

Monte Carlo Photon and Electron Dose Calculation Time Reduction Using Local Least Square Denoising Filters (국소 최소자승 잡음 감소 필터를 이용한 광자선 및 전자선 몬테칼로 선량 계산 시간 단축)

  • Cheong Kwang-Ho;Suh Tae-Suk;Cho Byung-Chul;Jin Hosang
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.138-147
    • /
    • 2005
  • The Monte Carlo method cannot have been used for routine treatment planning because of heavy time consumption for the acceptable accuracy. Since calculation time is proportional to particle histories, we can save time by decreasing the number of histories. However, a small number of histories can cause serious uncertainties. In this study, we proposed Monte Carlo dose computation time and uncertainty reduction method using specially designed filters and adaptive denoising process. Proposed algorithm was applied to 6 MV photon and 21 MeV electron dose calculations in homogeneous and heterogeneous phantoms. Filtering time was negligible comparing to Monte Carlo simulation time. The accuracy was improved dramatically in all situations and the simulation of 1 $\%$ to 10$\%$ number of histories of benchmark in photon and electron dose calculation showed the most beneficial result. The empirical reduction of necessary histories was about a factor of ten to fifty from the result.

  • PDF

Formulation of Calculation Method for Inducing Current by Aerial Power Distribution Line (가공 배전선에 의한 전자유도 발생 전류 계산 방법)

  • Lee, Sangmu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.30-36
    • /
    • 2015
  • The formulation of calculation method for electromagnetic inducing current by aerial power distribution line is established. Nearby telecommunication cables can be induced due to the leakage of neutral current because the neutral line of power distribution is grounded at every 50 m distance. By the existing calculation method, the neutral line is regarded as a shielding conductor and the neutral current roles as an inducing current. So the error range to real measurement value is largely extended because the changing effect of leakage current flowing in the ground is not reflected. The leakage current returns to the power substation through the ground and is cumulated as being closer to the substation. When this practical inducing mechanism is applied, the deviation rate of calculation can be drastically reduced within about 100 % range compared to 1000 % of the exsiting method.