• Title/Summary/Keyword: 석조식 아치교량

Search Result 2, Processing Time 0.018 seconds

A Study on Load Carrying Capacity of Ancient Stone Arch Bridge (고대 석조아치교량의 내하력에 관한 연구)

  • 정형식;황영철
    • Geotechnical Engineering
    • /
    • v.8 no.4
    • /
    • pp.31-40
    • /
    • 1992
  • The arch of an ancient stone arch bridge consists of blocky stone blocks. For the purpose of estimation of load carrying capacity of a stone bridge, the mechanically frail discontinuities between stone blocks should be taken account of. Since the current way of analysis regards the stone arch as a continuous member, the characteristic of discontinuties is not considered. In this paper, an ancient stone arch bridge is analyzed and load carrying capacity is estimated by Finite Element Method with the discontinuties between blocks being modelled as interface elements. From the result of the study, it is shown that the load carrying capacity of a stone arch bridge is dependent of friction angle and shear stiffness between arch blocks rather than compressive strength of arch block itself and the stone arch bridge of granite is more influenced by shear stiffness than friction angle. The load carrying capacity of HONG bridge of HEUNG GUK temple analyzed in this paper is estimated as that of a third grade bridge.

  • PDF

Full-Scale Test on Precast Concrete Arch Bridge with Reinforced Joint and Backfill (보강된 이음부와 뒤채움을 적용한 조립식 프리캐스트 콘크리트 아치교량의 실물모형실험)

  • Chung, Chulhun;Joo, Sanghoon;Choi, Dongchan;Lee, Jongyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.389-402
    • /
    • 2014
  • In this paper, the load test of full-scale precast concrete arch bridges considering reinforced joint and backfill was conducted. It is an improved method that the reinforced joint enhanced the structural performance of conventional masonry arch system which was proposed by previous researchers. The models of full-scale test are $10m(span){\times}3m$ (rise) and $10m(span){\times}2m$ (rise), which are 2 meters in width. The critical load position was shown at a third-span from the results of the pre-analysis. Based on the this results, the positions of load, measuring items and points were determined in experiments. As a result, the maximum load capacity of the specimen $10m{\times}2m$, a relatively small rise to span ratio (compared to the specimen $10m{\times}3m$), was higher than the specimen $10m{\times}3m$. It was evaluated that all the specimens have sufficient structural performance on the design load.