• Title/Summary/Keyword: 서지 제어

Search Result 116, Processing Time 0.03 seconds

A study on the functions of headings (표목의 기능에 관한 연구)

  • 김태수
    • Journal of the Korean Society for information Management
    • /
    • v.12 no.2
    • /
    • pp.9-35
    • /
    • 1995
  • Locating function of a particular item is more of added entry than a main entry heading. This function was expanded especially in the machine readable cataloging by introducing the control number and standard bibliographic number. Assembling function of the main entry heading is on a level with that of cross reference and notes, added entries, uniform headings. Links among all variant forms of a heading in hypercatalog will be made for collocating of all publications of a given author. The link of bibliographic records in this catalog can be freed from the dependence on standardized heading form. The function of the catalog is not affected even though by abandoning the concept of main entry heading. Further efforts should be made to raise users' finding opportunities through expansion of acces points and linking devices among related records.

  • PDF

Case Study of Repair Works on Surge Suppression Device for Booster Pumping Station (가압펌프장의 수격완화설비에 대한 보수·보강 사례)

  • Kim, Sang-gyun;Lee, Dong-keun;Lee, Gye-bok;Kim, Kyung-yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.20-26
    • /
    • 2005
  • When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity. The field tests on the waterhammer were carried out for Pangyo booster pumping station in which had six booster pumps and two in-line pumps with the motor of output 1,700 kW, respectively. The booster pumping station was equipped with the pump control valve as the main surge suppression device, and the surge relief valve as auxiliary one. But the pump control valve had not early controlled in the planned closing mode, the slamming occurred to the valve of which abruptly closed during the large reverse flow. Because the positive pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the pump control valve was damaged. After the air chambers were additionally installed in the booster pumping station, it was preyed that the water supply system acquire the safety and reliability on the pressure surge.

A Study on Performance Characteristics with the Control System of CNG Regulator (CNG 레귤레이터의 제어 방식에 따른 성능특성 연구)

  • Seo, Ji-Won;Yang, Jeong-Jik;Kim, Jin-Ho;Lim, Jong-Wan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2017
  • The domestic vehicles remodeling the "CNG Bi-fuel Kit" are mostly in operation with installing the mechanical regulator applying the Diaphragm. However, due to the material characteristics of Diaphragm and characteristics of mechanical pressure control method, various problems are happening. This study tries to deduce the improvement plan through the checking of performance characteristics according to the pressure control method of CNG regulator and progress of comparative analysis. According to the test result, the decompression method applying the Diaphragm has advantage compared to the method applying the Piston. Furthermore, it was confirmed that through the electronic pressure control, it is possible to improve the general performance of the regulator.

Development of the System Controller for Multi Functional Motor Protection (다기능 모터보호장치를 위한 시스템 제어기 구현)

  • Seo, Ji-Yun;Kim, Hyun-Su;Jung, Sung-Hak;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.830-832
    • /
    • 2016
  • 본 연구에서는 일반 산업현장에서 동력원으로 가장 편리하게 사용하고 있는 장치인 모터의 결함을 사전에 모니터링하기위한 연구를 수행하였다. 기존의 EOCR(electronic over Current relays)을 통해 모터의 전기적 결함에 따른 모터보호 및 전기적 결함측정뿐만 아니라 모터의 절연저항, 구동시간, MC(magnet contactor) 접점횟수, 베어링온도측정, 모터회전수 측정 등 전기적 결함과 기계적 결함을 동시에 모니터링 할 수 있는 다기능 모터보호장치를 구현하고자 하였다. 이를 위하여 다기능 모터보호장치의 데이터입력 및 제어장치, 디스플레이 및 인터페이스 장치를 구현하였고, 실제 MCC시스템과의 연동을 통해 동작특성평가를 수행하였다. 인위적인 전기적 결함 및 기계적 결함을 유발시키고 이를 검출하는 모의실험을 수행한 결과 전기적 결함과 기계적 결함 각각에 대해 100% 검출 가능함을 확인하였다.

  • PDF

Shipping systems using optimal route algorithms (최적경로 알고리즘을 활용한 운송 시스템)

  • Ji-Yeon Seo;So-Yeon An;Seul Lee;Seo-Jeong Oh;Sang-Oh Yoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.1084-1085
    • /
    • 2023
  • 현재 국내 항만에서의 작업은 대부분 수작업으로 진행되기 때문에 다양한 안전사고 발생과 시간 및 비용 등의 손실이 우려된다. 이를 해소하고자 최적경로 알고리즘을 이용한 AGV 차량 및 자동화 크레인으로 무인 스마트 항만을 제안한다. RFID 인식으로 컨테이너의 정보를 확인하고, 각 경로의 노드 정보가 담긴 QR 코드 인식을 통해 최적으로 목적지에 달성하는 것이 핵심이다. 본 논문은 이러한 기능으로 시간 및 비용 절감, 효율 상승과 인명피해 및 안전사고 예방을 목표로 한다.

Design of PID Type Fuzzy Logic Acceleration Controller for Turbojet Engine Using High-gain Observer (고이득 관측기를 이용한 터보제트 엔진의 PID 퍼지 추론 가속도 제어기 설계)

  • Jie, Min-Seok;Kim, Dae-Gi;Hong, Gyo-Young;Ahn, Dong-Man;Hong, Seung-Beom
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.1
    • /
    • pp.107-114
    • /
    • 2013
  • In this paper, we propose controller to control the acceleration of unmanned aircraft turbojet engine. The high-gain observer to estimate the rotational speed of compressor is used, and the turbojet engine controller applying fuzzy heuristic techniques and PID control algorithm are designed. fuzzy PID controller produces the flow control input to prevent the surge and flame-out phenomena at the acceleration and deceleration of the turbojet engine. The standard acceleration is set and the fuel flow control is defined by the fuzzy heuristic. Computer simulations are performed using MATLAB in order to verify the performance of the proposed controller.

A Study on the Countermeasure Algorithm for Power System Disturbance in Large Scale Fuel Cell Generation System (대용량 연료전지발전시스템의 계통외란방지알고리즘에 관한 연구)

  • Kim, Gi-Young;Oh, Yong-Taek;Kim, Byung-Ki;Kang, Min-Kwan;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5550-5558
    • /
    • 2015
  • Recently, fuel cell with high energy efficiency and low CO2 emission is energetically interconnected with power system. Especially, FCGS(Fuel Cell Generation System) which usually operates at high temperature, is being developed and installed in the form of large scale system. However, it is reported that power system disturbances related to surge, harmonic and EMI have caused several problems such as malfunction of protection device and damage of control device in the large scale FCGS. In order to solve these problems, this paper presents a modeling of operation characteristics of FCGS by PSCAD/EMTDC, ETAP, P-SIM software. And also, this paper proposes countermeasure algorithms to prevent power system disturbances. From the simulation results, it is confirmed that the proposed algorithm is useful method for the stable operation of large scale FCGS.

A Study on the Functional Requirement of Subject Authority Data for Subject Authority Control (서지레코드의 주제전거를 위한 FRSAD 모형 연구)

  • Park, Zi-Young
    • Journal of Information Management
    • /
    • v.42 no.1
    • /
    • pp.113-135
    • /
    • 2011
  • The final report of the Functional Requirement of Subject Authority Data(FRSAD), the 3rd report of the FRBR family model, is announced by IFLA in June, 2010. This model represents the international trends of subject authority control and suggests a direction to the future subject authority record suitable for the FRBR system. Therefore aims of this study are to analysis the FRSAD model in context of the FRBR family and apply the model to the subject headings and bibliographic records of Korean National Library. For these aims, we analyse the model focused on the entities, attributes, and relationships between entities. From this analysis, we have found the openness of the FRSAD, which does not force a certain entity types and has focus on the conceptual aspects of the entity not only the form of the headings. Moreover, we suggest examples by applying the FRSAD frame and facets of the FAST to the Headings of the NLSH and related KORMARC fields. The scope of this study is the additional entities of the FRBR groups, so personal names, corporate names, family names and titles are not included. As a result, it is necessary to determine the criteria for the types of thema and to apply the types consistently in bibliographic records. A follow up research will be needed to suggest more detailed examples.

An Investigation into Coordinated Control of 4-wheel Independent Brakes and Active Roll Control System for Vehicle Stability (차량 안정성 향상을 위한 ESC와 ARS의 통합 샤시 제어 알고리즘 개발)

  • Her, Hyundong;Yi, Kyongsu;Suh, Jeeyoon;Kim, Chongkap
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • This paper describes an investigation into coordinated control of electronic stability control (ESC) and active roll control system (ARS). The coordinated control is suggested to improve the vehicle stability and agility features by yaw rate control. The proposed integrated chassis control algorithm consists of a supervisor, control algorithms, and a coordinator. The supervisor monitors the vehicle status and determines desired vehicle motions such as a desired yaw rate and desired roll motion based on control modes to improve vehicle stability. According to the corresponding the desired vehicle dynamics, the control algorithm calculated a desired yaw moment and desired roll moment, respectively. Based on the desired yaw moment and the desired roll moment, the coordinator determines the brake pressures and the ARC motor torques based on control strategies. Closed loop simulations with a driver-vehicle-controller system were conducted to investigate the performance of the proposed control strategy using CarSim vehicle dynamics software and the integrated controller coded using Matlab/Simulink.

A Development of Intelligent Controller for Phase Control in Main Circuit Breaker (주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발)

  • Oh, Yong-Kuk;Kim, Jae-Won;Ryu, Joon-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.755-761
    • /
    • 2017
  • In railways powered by AC power, the main circuit breaker (MCB) is used for supplying the electric power to the catenary of the vehicle. Generally, the main circuit breaker is located between the pantograph and the main transformer, and the phase of the power applied to the vehicle changes according to the operation timing of the main circuit breaker. The operation of the main circuit breaker should be actively controlled according to the phase of the power source, since the phase of the power causes unintended transient states in the vehicle's electrical system in the form of an inrush current and surge voltage. However, the MCB has a delay time when it operates which is not constant. Therefore, an intelligent controller is needed to predict the operation delay time and control the opening and closing of the MCB.