• Title/Summary/Keyword: 서리두께

Search Result 12, Processing Time 0.029 seconds

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.

Behaviors of Frost Formation on a Plate Fin Considering Fin Heat Conduction (휜의 열전도를 고려한 평판 휜에서의 착상 거동)

  • Kim, Jeong-Su
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.12
    • /
    • pp.51-60
    • /
    • 2009
  • 본 연구에서는 착상 조건 하에서 열교환기 휜의 열전도를 고려하여 휜 표면에서의 착상 거동을 예측하기 위하여 수학적 모델을 제시한다. 이 때, 공기측은 착상 현상에 대한 3차원 유동 변화의 영향을 고려한다. 서리층 두께에 대한 해석 결과는 실험 결과를 최대 10% 오차 내에서 잘 예측한다. 유동에 수직한 방향(z-dir.)의 서리층 두께 성장은 휜의 열전도에 의해 휜 바탕 근처에서 활발하고, 휜 끝으로 갈수록 지수함수적으로 둔화된다. 휜의 열전도를 고려한 경우에 비해 휜의 표면온도가 일정한 조건에서 서리층 두께는 최대 2배, 열전달량은 평군 10% 정도 과대 예측한다. 따라서, 열교환기 휜에서의 착상 거동을 정확하게 예측하기 위해 착상 모델 해석 시 휜의 열전도를 고려해야 한다. 휜의 열전도 고려 유무에 따른 착상 거동의 차이를 보완하기 위해 열전달량에 대한 등가온도를 산출하며, 이를 근거로 무차원 등가 온도 상관식을 도출한다.

  • PDF

Correlations of Frost Properties Considering the Environmental Parameters over a Cold Flat Plate (수평편판에서의 착상인자를 고려한 서리 물성치의 상관식)

  • Lee, Kwan-Soo;Kim, Yong-Chul;Jhee, Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1046-1052
    • /
    • 2001
  • This study has been performed experimentally to measure the frost properties over a cold flat plate in order to obtain the correlations of the frost properties with various environmental parameters. Correlations of the frost surface temperature, thickness, density, and thermal conductivity are presented along with the experimental results as a function of environmental parameters, distance from the leading edge of test plate, and time. These correlations can be used to predict the frost properties with a maximum error of 8% in the following ranges : air temperature 15∼25$\^{C}$, relative humidity 60∼80%, air velocity 1∼3m/s and cooling plate temperature -15∼-25$\^{C}$.

A Study of Frost Formation on Different Hydrophilic Surfaces (다른 친수성능을 가진 두 표면에서의 착상에 관한 연구)

  • 김철환;신종민;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.519-524
    • /
    • 2002
  • An experimental study has been conducted to investigate the effects of surface energy on frost formation. Test samples with two different surfaces are installed in a wind tunnel and exposed to a humid airflow. Dynamic contact angles (DCA) for these surfaces are $23^{\circ}\;and\;88^{\circ}$, respectively. The thickness and the mass of frost layer are measured and used to calculate the frost density while frost formation is visualized simultaneously with their measurements. Results show that frost density increases as time increases at specific test conditions. The air Reynolds number, the airflow humidity and the cold plate temperature are maintained at 12,000, 0.0042 kg/kg and $-21^{\circ}C$, respectively. The surface with a lower DCA shows a higher frost density during two-hour test, but no differences in the frost density have been found after two hours of frost generation. Empirical correlations for thickness, mass and density are assumed to be the functions of the test time and DCA.

A study on the performance of the finned tube heat exchanger affected by the frosting using CFD tool (전산해석을 이용한 착상이 핀튜브 열교환기 성능에 미치는 영향에 관한 연구)

  • Kim, Sung-Jool;Choi, Ho-Jin;Ha, Man-Yeong;Bang, Seon-Wook
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2738-2743
    • /
    • 2008
  • We conducted a study by computational simulation about the effects of frost thickness on the pressure drop and heat transfer characteristics as whole heat exchanger configuration changes. In order to perform the analysis for validation, we assumed that frost properties have constant values and the frost layers that are formed on the fin and tube surfaces are uniform. In order to find the constant thermal conductivity of frost layer, a variety of frost thermal conductivities are performed in our work and compared with the results by Lee et al. [4] and Yang et al. [5] proposed many experimental data about the 2-rows and 2-columns finned tube heat exchanger. The numerical results agreed well with the experimental data when frost conductivity is 0.07W/mK. After the validation had performed, we applied this procedure to the finned tube heat exchanger of domestic refrigeration and investigated the thermo-hydraulic characteristic of the heat exchanger affected by frost thickness according to the inlet velocities and temperatures of air considering the configuration change such as fin pitch.

  • PDF

Empirical Correlations of Frost Thickness and Frost Surface Temperature on Heat Exchanger Fin (열교환기 휜에서의 서리층 두께와 서리층 표면온도의 실험 상관식)

  • Kim, Kyoung-Min;Kim, Jung-Soo;Kim, Jang-Hyun;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.798-803
    • /
    • 2009
  • In this study, dimensionless correlations of frost properties (i.e. the thickness and surface temperature of frost) on heat exchanger fin with nonuniform temperature distribution are proposed from frosting experiments. We analyzed the local fin temperature distribution, frost thickness and frost surface temperature on a 2D fin; in the airflow direction and the direction perpendicular to airflow. As a result, the frost growth on the fin had a close relation with fin heat conduction. The dimensionless correlations for the average frost properties were expressed as a function of dimensionless temperature, humidity ratio, Reynolds number, and Fourier number. These correlations agreed well with experimental data with the error less than 14%.

  • PDF

Characteristics of the Lower Boundary Layer during Frost Nights (찬공기 호수지형에서 서리발생시 하층대기 특성 - 경상남도 하동을 중심으로)

  • 황규홍;이정택;허승오;심교문
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2001.06a
    • /
    • pp.65-67
    • /
    • 2001
  • 경계층(boundary layer)은 대류권(troposhpere)의 일부분으로써 지구 표면에 직접적인 영향을 주고, 두께는 지표에서 100∼3000m이다. 고기압의 영향을 받는 지역에서 수직 경계층은 일출후부터 일몰 전까지인 낮 시간에 난류 혼합층(turbulent mixed layer), 낮 시간에 형성된 혼합층이 야간에 잔류하는 층, 야간 안정 경계층(Stable Boundary Layer:SBL)으로 나눌 수 있다(Stull, 1988).(중략)

  • PDF

An experimental study of frost forming on the horizontal cylinder under cross flow (직교유동 내에 놓인 수평 실린더에서 서리 생성에 관한 실험적 연구)

  • 이윤빈;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.448-456
    • /
    • 1999
  • Variations of thickness and effective thermal conductivity of frost forming on the horizontal] cylinder with respect to time were measured under cross flow. The local heat flux around the cylinder was determined by measuring the radial temperature distribution in the cylinder having small holes drilled axially in which T-type thermocouples were inserted, then by using one dimensional cylindrical heat conduction equation. The thickness and the surface temperature of the frost layer around the cylinder were measured periodically while developing the frost. Each experiment was peformed by varying the Reynolds number, the temperature, and the humidity condition. Specially the dew point temperature of the most cases was below the freezing point. Experimental data showed that the frost layers on the front and the rear surface were thicker than those on the top and the bottom one which was near the separation point. The thickness and effective thermal conductivity of the frost layer were affected by inlet air velocity, temperature, and humidity. Moreover, the effective thermal conductivity and the effective thermal resistance increase with respect to time.

  • PDF

Investigation of Forest Maschines and Tools in Central Europe (1) - On the Ax - (유럽 중부지방(中部地方)의 산림작업용(山林作業用) 기기(機器)의 조사검토(調査検討) (1) - 도끼편 -)

  • Ma, Sang Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.53 no.1
    • /
    • pp.62-74
    • /
    • 1981
  • The developed record of forest maschines and tools in West Germany, Austria and Swiss, their technical characteristics and the working methods with them have been tried to investigate through the study of literature and observation. The aim of this investigation is to find out and introduce the technical information for training our forest men with them and for improving or developing our forest maschines and tools. Although ax chosen as first report for this aim is the oldest tool in the mankind history, still this is widely using in the forest work. And this has some special working filed that any other maschines could not overcome and sometimes should be recommended in the agronomical sideview. Through this investigation several points could be proposed as the technical informations when we will try to improve our ax 1. Radius of as-face curvature is proposed to be 150 mm and it's central point to be passed at one third point near to ax-eye. 2. Cutting angle is proposed to be $30^{\circ}$, ax-thick at 12 mm distance from ax-face to be 4 mm, thick at 30 mm distance from face to be 5 to 6 mm and ax-face width to be $125{\pm}5mm$. 3. Neck size is proposed to be $3.5{\pm}0.5{\times}5.5{\pm}0.5cm$ with a little curvature and neck thick from ax-house to be more than 1.5 cm. 4. Ax weight is proposed to be 1,000 gr with the stupid back and the sharp front. 5. The handle length of ax will be followed to the arm length of our forest workers.

  • PDF

An Experimental Study of Frost Formation on the Horizontal Cylinder (수평 실린더 표면의 착상에 대한 실험적 연구)

  • Paik, Sang-Jin;Lee, Yoon-Been;Ro, Sung-Tack
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF