• Title/Summary/Keyword: 생활폐기물자원회수시설

Search Result 12, Processing Time 0.021 seconds

동부권 광역자원회수시설 소각설비

  • Bae, Jae-Hong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.10
    • /
    • pp.12-18
    • /
    • 2009
  • 현재 경기도 이천시에 운영중인 동부권 광역자원회수시설의 사례를 통해 생활폐기물 소각설비의 구성이 어떻게 이루어지는지 이해를 돕고자 한다.

  • PDF

Analyzing Changes in Spatial Extent of Influences from a Resource Recovery Facility in the Aspect of Housing Prices - A Case Study on the Nowon Facility in Seoul using Hedonic Price Model - (주택가격에 대한 자원회수시설 영향권 변화에 대한 연구 - 헤도닉 가격 모형을 이용한 노원자원회수시설에 대한 사례 -)

  • Kim, Hyunkyung;Park, Kyung Nan;Sohn, Chul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.27 no.3
    • /
    • pp.43-59
    • /
    • 2024
  • This study focuses on identifying the impacts of the Nowon resource recovery facility in Seoul, Korea, on the real transaction price of apartments in the neighboring areas between 2006 and 2022, and the spatial extent of the impact. Resource recovery facilities, which generate electricity and heating energy while disposing of waste, are typical unwanted facilities that have a negative impact on neighboring property prices. As direct landfilling of household waste is banned in Seoul from 2026 and nationwide from 2030, the demand for the expansion of waste incineration facilities, including resource recovery facilities, is expected to increase rapidly. In addition, social disputes related to the decline in neighboring property prices are expected to increase. This study analyses the impact of the Nowon resource recovery facility on surrounding apartment prices over a 17-year period since 2006 using hedonic price models for apartments, and finds that the Nowon resource recovery facility consistently has a negative impact on nearby apartment prices, the spatial extent of the impact is at least 1,000 meters from the facility, and the intensity of the negative impact weakens as the distance from the facility increases. The results of this study differ from recent studies finding that the spatial extent of the impact of resource recovery facilities in Seoul on surrounding property prices is limited within 500~600 meters, suggesting that a broader approach is needed to systematically manage social conflicts that are expected to increase with the growing social demand for resource recovery facilities.

Cost-Benefit Analysis by Resource Recovery Facility for Municipal Waste -Focus on Gangwon Province- (생활폐기물 자원화시설의 편익분석 -강원도 중심으로-)

  • Han, Young-Han;Lee, Hae-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2833-2845
    • /
    • 2012
  • In this study, the amount of waste resource that could be recovered was analyzed. The installation and operation costs of waste resource recovery for both single- and multi-regional facility were calculated, and compared with the costs of landfill to investigate the feasibility of them. RDF(Refuse Derived Fuel) process and resource recovery by incineration process were considered as waste resource recovery facility. And, the multi-regions for cost analysis were established on the basis of the proper generation rate of municipal waste with the consideration of combustible ratio. The study results showed that single region facility for both RDF and incineration process has no economic benefit, compared with the landfill method. For the multi-regional facility, RDF process could save a large cost than the landfill method, but the incineration facility couldn't. Separate from the economic benefits, the waste resource recovery should be importantly considered when considering the depletion of fossil fuel, global warming, environmental toxicity, and the enormous expenses due to social conflict and confuse. When the CDM(Clean Development Mechanism) is vitalized in the near future, the additional economic benefits by CERs(Certified Emission Reductions) could be expected. CERs for RDF facility is corresponding to about 256.5 billion won, and CERs for incineration facility is corresponding to about 54 and 77.4 billion won for single- and multi-regional facility, respectively.

Estimation of Energy Recovery Rate of Municipal Waste Incineration Facilities through Measuring Instruments (계측기기 측정을 통한 생활폐기물 소각시설의 에너지 회수효율 산정 연구)

  • Kwon, Young-Hyun;Kang, Jun-Gu;Ko, Young-Jae;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Park, Ho-Yeun;Jeon, Tae-Wan;Lee, Young-Ki
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.770-776
    • /
    • 2018
  • This study measured the energy recovery rate of each municipal waste incineration facility according to the revised energy recovery rate estimation method, which targeted four municipal waste incineration facilities (Unit No. 7). The results calculated by the measuring instruments were used for each factor to estimate the recovery rate, and the available potential of available energy was examined by analyzing the energy production and valid consumption. As a result of the low heating value, 2,540 kcal/kg was calculated on average when the LHVw formula was applied, which is approximately 116 kcal/kg higher than the average design standard of 2,424 kcal/kg. The energy recovery rate was calculated as 96.9% on average based on production and 67.5% based on effective consumption, and the analysis shows that approximately 29.4% energy can be used.

Feasibility of Powdered MSWI Ash Melted Slag as a Seed Crystal of crystallization reaction for the Removal of Phosphorus from Sewage (하수중 인제거를 위한 정석탈인반응의 정석재로서 소각분말 용융슬래그의 이용 가능성 평가)

  • Kim, Choong Gon;Shin, Hyun Gon;Kim, Seung Won
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • This study is a fundamental research to test the applicability of powdered MSWI(Municipal Solid Waste Incinerator) ash melted slag as a seed Crystal for crystallization reaction. Powdered ash melted slag was melted at $1100^{\circ}C$ and ground to lesser than 0.35mm. According to the result of the tests, calcium, enough for crystallization reaction, was eluted from powdered ash melted slag. Moreover, sample(Phosphorus concentration is under 10 mg/L), more than 90% of Phosphorus can be removed. So we rectify the Phosphorus concentration to 100 mg/L. Alkalinity, being well known that it interferes crystallization reaction, effect was studied for synthetic solution(100 mg/L initial Phosphorus concentration, 50 mg/L calcium, pH 8, 1% powdered ash melted slag dosage). For this result, we know that Phosphorus removal is hindered by alkalinity. In addition, the effect of reaction temperature was performed at the same method. The reaction velocity was increased through raising the reaction temperature.

Development of Carbon Dioxide Emission Factor from Resource Recovery Facility (폐기물자원회수시설의 이산화탄소 배출계수 개발)

  • Kim, Seungjin;Im, Gikyo;Yi, Chi-Yeong;Lee, Seehyung;Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.4 no.1
    • /
    • pp.51-61
    • /
    • 2013
  • To address the problems associated with climate change and energy shortage, Korea has been making efforts to turn waste materials into usable energy. Due to the ongoing efforts to convert waste materials into energy, waste incineration is expanding to utilize the heat generated, and the subsequent greenhouse gas emissions from these waste material incineration are expected to increase. In this study, a municipal waste incineration plant that generates heat and electricity through heat recovery was selected as a subject facility. Methods for estimating the greenhouse gas emissions in the municipal waste incineration plant that was selected as a subject plant were sought, and the greenhouse gas emissions and emission factor were estimated. The $CO_2$ concentrations in discharge gas from the subject facility were on average 6.99%, and the result from calculating this into greenhouse gas emissions showed that the total amount of emissions was $254.60ton\;CO_2/day$. The net emissions, excluding the amount of greenhouse gas emitted from biomass incineration, was shown to be $110.59ton\;CO_2/day$. In addition, after estimating the emissions by separating the heat and electricity generated in the incineration facility, greenhouse gas emission factors were calculated using the greenhouse gas emissions produced per each unit of output. The estimated emission factor for heat was found to be $0.047ton\;CO_2/GJ$ and the emission factor for electricity was found to be $0.652ton\;CO_2/MWh$. The estimated emission factor was shown to be about 17% lower than the $0.783ton\;CO_2/MWh$ emission factor for thermal power plants that use fossil fuels. Waste material types and fossil carbon contents were evaluated as being the factors that have major effects on the greenhouse gas emissions and emission factor.

Development of Separation System with Rotating Rakes for Recovery of Film-based Plastics (기계식(機械式) 회전(回轉)레이크를 이용(利用)한 생활계(生活界) 폐기물(廢棄物) 필름류(類) 선별장치(選別裝置) 개발(開發)에 관(關)한 연구(硏究))

  • Lee, Byung-Sun;Na, Kyung-Duk;Han, Sang-Kuk;Choi, Woo-Zin;Park, Eun-Kyu
    • Resources Recycling
    • /
    • v.19 no.3
    • /
    • pp.24-32
    • /
    • 2010
  • In the present work, a new separation system with rotating rakes has been developed to separate the film-based plastics from the recyclable materials, and environment assessment is also carried out during operation of the device. Capacity of the device was about 5.3 ton/hr at a rakes rotation speed of 26.0 rpm (the number of rakes in the 1st, 2nd and 3rd trials were 39, 52 and 48, respectively) and a belt conveyor speed of 38.5m/min, which satisfied the initial design capacity (5.0 ton/hr). Recovery ratio and purity of the plastic films were 92.6% and 96.5%, respectively at a rotation speed of 28 rpm. The levels of noise, vibration and particulate emission were below material standard regulatory limits. Plastic refused fuel (RPF) was also prepared with the recovered films. The calorific value and chlorine content of the prepared RPF were 9,740 kcal/kg and 0.18%, respectively which satisfy the first grade quality specification of the Korean RPF standard. As a result of this work, recovery of energy resources from the municipal solid waste is possible by adopting the developed separation device.

Size Distribution and Physicochemical Characteristics of MSW for Design of Its Mechanical Biological Treatment Process (폐기물전처리(MBT)시설 설계를 위한 생활폐기물의 입도분포 및 물리화학적 특성에 관한 연구)

  • Park, Jin-Kyu;Song, Sang-Hoon;Jeong, Sae-Rom;Jung, Min-Soo;Lee, Nam-Hoon;Lee, Byoung-Chul
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2008
  • There has been a recent trend in Korea that treatments for combustible wastes among municipal solid waste (MSW) by those methods, such as incineration and landfill are restricted as much as possible and Mechanical Biological Treatment (MBT) are encouraged actively in order to promote resource recovery. To build and operate properly these facilities, the physicochemical characteristics of MSW should be analyzed precisely beforehand. In particular, designing a crusher or separator properly which is the main process in MBT facilities of MSW. require the information on the size distribution characteristics of MSW, but they are nor sufficient in the qualities and quantities yet as of now. Accordingly, this study aims to evaluate size distribution characteristics of MSW and its physicochemical characteristics by size. The samples of MSW were collected from detached dwelling area, apartment area, business area, and commercial area of A city in Korea. According to the result of analysis, paper records 29.78~60.02% by wet weight basis, so it was the most regardless of the regions where the wastes were generated. And in terms of element analysis, Carbon(C) was 34.77~44.39%, the largest friction, and Oxygen(O) was the next occupying 19.46~33.71%. As indices of RDFs, Chlorine(Cl) was 0.39~0.83%, so it was less than the standard, 2.0%(by dry weight basis); moreover, Sulfur(S) did not exceed the standard, 0.6%, either. In the size distribution of MSW, waste fraction ranging 50~80mm in diameter was the most in combustible waste while 30~50mm was in incombustible waste.

  • PDF

A Study on Improvement Measures of Energy Recovery Efficiency through Analysis of Operational Status of Municipal Solid Waste Incineration Facilities (생활폐기물 소각시설의 운영 실태 분석을 통한 에너지회수 효율 개선방안 검토)

  • Park, Sang-Jin;Phae, Chae-gun
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.762-769
    • /
    • 2018
  • This study was carried out to examine the improvement plan by analyzing the characteristics of imported wastes, operation rate, and benefits of energy recovery for incineration facilities with a treatment capacity greater than 50 ton/day. The incineration facility capacity increased by 3,280 tons over 15 years, and the actual incineration rate increased to 2,783 ton/day. The operation rate dropped to 76% in 2010 and then rose again to 81% in 2016. The actual calorific value compared to the design calorific value increased by 33.8% from 94.6% in 2002 to 128.4% in 2016. The recovery efficiency decreased by 29% over 16 years from 110.7% to 81.7% in 2002. Recovery and sales of thermal energy from the incinerator (capacity 200 ton/day) dominated the operation cost, and operating income was generated by energy sales (such as power generation and steam). The treatment capacity increased by 11% to 18% after the recalculation of the incineration capacity and has remained consistently above 90% in most facilities to date. In order to solve the problem of high calorific value waste, wastewater, leachate, and clean water should be mixed and incinerated, and heat recovery should be performed through a water-cooled grate and water cooling wall installation. Twenty-five of the 38 incineration facilities (about 70%) are due for a major repair. After the main repair of the facility, the operation rate is expected to increase and the operating cost is expected to decline due to energy recovery. Inspection and repair should be carried out in a timely manner to increase incineration and heat energy recovery efficiencies.