• Title/Summary/Keyword: 생체외 실험

Search Result 139, Processing Time 0.024 seconds

A STUDY OF THE CYTOTOXICITY OF ROOT CANAL SEALER IN VITRO (생체외 실험을 이용한 근관충전용 Sealer의 세포독성에 관한 연구)

  • Lee, Sang-Tag;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.62-84
    • /
    • 1991
  • The purpose of this study was to evaluate the cytotoxicity of four root canal sealers(Tubliseal, AH26, Apatite Root Canal Sealer I, Apatite Root Canal Sealer II) in Vitro. The root canal sealers were mixed and filled in molds which were $14{\times}1.25mm$ in diameter, in height to use for cell counting and agar overlary method, and $7{\times}1.25mm$ for millipore filter method and set for 7 days to use for experiment. Silicone and copper plate were used for negative and positive control respectively. Using the culture of L929 fibroblast, total cell number and vital cell number were counted and the ratio of vital cell number to total cell number was calculated on 2 nd, 4 th, 6 th experimental day, and the change of cell membrane permeability was tested by agar overlay method, and the succinate dehydrogenase activity was tested by millipore filter method. The obtained results were as follows. 1. In ail experimental groups, the mitotic activity of fibroblast was reduced when compared with that of negative control group, so ail experimental groups showed cytotoxicity. Apatite Root Canal Sealer I group exhibited mild cytotoxicity, and Tubliseal, AH26, Apatite Root Cenal Sealer II groups exhibited severe cytotoxicity. 2. In the test of the change of cell membrane permeability by agar overlay method, all experimental groups showed cytotoxicity. AH26 group exhibited mild cytotoxicity, and Apatite Root Canal Sealer I group exhibited moderate cytotoxicity, and Tubliseal and Apatite Root Canal Sealer II group exhibited severe cytotoxicity. 3. In the test of SDH activity by millipore filter method, there was no cytotoxicity in Apatite Root Canal Sealer I and Apatite Root Canal Sealer II group, but Tubliseal and AH26 group showed mild cytotoxicity.

  • PDF

Removing the Motion Artifacts in the Pulse Signal Detected from the PFS Using the Quasi-periodicity (유사 주기성을 이용한 PFS 펄스 신호의 동잡음 제거)

  • Lee, Han-Wook;Chun, Joong-Chang;Jeong, Won-Geun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.591-598
    • /
    • 2016
  • For the mobile healthcare environment, it is important to measure the exact biomedical signals in real time, and another key point is to design mobile healthcare devices with low power consumption. In this paper, we propose a method in which the piezo film sensor(PFS), having a low power characteristic, is used to measure the pulse signal synchronized with the heart rate from the radial artery. The critical issue in the bio-signal processing is the existence of the motion artifacts. To dissolve this problem, we have applied the periodic moving average filter using the quasi-periodicity of the pulse signal in addition to the conventional method of the adaptive filtering using the reference signal. Results of simulation and experiments are presented to confirm that the quasi-periodicity of the PFS signal can be used to eliminate completely the motion artifacts which still appears after the adaptive filtering.

Epidural Space Identification Device Using Air-filled Catheter (공기도관을 사용하는 경막외강 자동탐지기구)

  • 강재환;김현식;김경아;김상태;배진호;임승운;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.9-13
    • /
    • 2003
  • An assist device was developed to identify the epidural space by continously monitoring the air-filled catheter pressure. The pressure signal appropriately amplified and filtered enabled to alarm the needle introduction into the epidural space by thresholding detection. Ten LEDs provided a visual change of catheter pressure before alarming for user convenience. Clinical trials were performed in 30 patients with 83% success rate at the first trial. When failed, the second trial was enough for successful anesthesia. The air volume introduced during each anesthesia was less than 1ml, causing side effects. Air filling of the catheter could also minimize infection possibility. Therefore, the present device guarantees safe anesthesia with user convenience.

Preparation and Release Profile of N8f-loaded Polylactide Scaffolds for Tissue Engineered Nerve Regeneration (조직공학적 신경재생을 위한 NGF를 함유한 PLA 담체의 제조 및 방출)

  • 전은경;황혜진;강길선;이일우;이종문
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.893-901
    • /
    • 2001
  • We developed the nerve growth factor (NGF) loaded poly (L - lactide) (PLA) scaffolds by means of emulsion freeze drying method to the possibility for the application of the nerve regeneration of spinal cord disease and the degeneration in Alzheimer's disease. The release amount of NGF from NGF loaded PLA scaffold were analyzed over a 4 week period in vitro at phosphate buffered saline (PBS), pH 7.4, at $37^{\circ}C$. It can be observed the open cell pore structure of porous scaffolds and can be easily controlled the pore structure by the controlling of formulation factors resulting in the controlling of the release rate and the release period. The stability of NGF during the preparation of PLA scaffold was evaluated by comparing the released amounts of total NGF, assayed NGF enzyme - linked immunosorbent assay (ELISA). Released NGF has been found to enhance the neurite sprouting and outgrowth from pheochromocytoma (PC-12) cells. These results suggest that the released NGF from NGF loaded PLA scaffold such as conduit type can be very useful for the nerve regeneration in the neural tissue engineering area.

  • PDF

The Analysis of EEG Signal Responding to the Pure Tone Auditory Stimulus (청각자극의 반송 주파수에 따른 뇌전위 신호의 해석)

  • Choe, Jeong-Mi;Bae, Byeong-Hun;Kim, Su-Yong
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.383-388
    • /
    • 1994
  • Chaotic analysis of EEG signal responding to auditory stimulus with various carrier frequency and constant triggering frequency is given in this paper. The EEG signal is obtained from the digital 12channel EEG system made in our laboratory. The carrier frequency is varied from 1 kHz to 3 kHz by 0.5 kHz step. Chaos analysis such as pseudo phase space portrait, Lyapunov exponent, and so on is done on the auditory stimulated evoked potential. This result is found to be quite consistent with the well known results from the psychological perception theory.

  • PDF

Preparation and Characterization of Casein Nanoparticles with Various Metal Ions as Drug Delivery Systems (다양한 금속 이온을 이용한 카세인 단백질 나노입자 형성 및 약물 전달체 특성 연구)

  • Minju Kim;Seulgi Lee;Joon Sig Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.2
    • /
    • pp.121-125
    • /
    • 2023
  • Casein is a milk protein and one of the most important nutrients in milk. The composition is over 80% in cow's milk and about 20~45% in human's milk. Casein is highly biocompatible and biodegradable, so it has been studied for various biomedical materials applications as well as drug delivery systems. It is widely known that casein can be prepared as nanoparticles in the presence of the Ca2+ metal ion. Because casein is amphiphilic, hydrophobic drugs could be loaded inside to form a protein-based drug delivery system. In this study, we studied the optimum conditions for casein nanoparticle formation using natural metal ions present in the body, such as calcium, magnesium, zinc, and iron. It was confirmed that nanoparticles have a uniform size of around 150 nm and negative zeta potential values. In addition, it was demonstrated that casein nanoparticles have a cell viability of more than 80% and efficient intracellular uptake properties using confocal microscopy. From the results, it was also shown that the casein nanoparticles prepared using various metal ions have the potential to be biocompatible drug delivery carriers.

A Case Study on Performance Analysis of Antimicrobial Copper Film Attaching to Window for Responding to COVID-19 and Others (코로나19 등 대응을 위한 "유리창 부착용 항바이러스 동필름" 성능분석 사례연구)

  • Kim, Seong Je
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.23-40
    • /
    • 2021
  • In the era of the global coronal 19 pandemic, there is a risk of cross-infection in hospitals at the stage where treatments and vaccines are currently being developed and marketed, so individuals should enhance their acquired immunity and generalize their living systems by the performance of copper ions in the social environment. In order to prevent the spread of infection, the need for anti-bacterial film and its efficacy were analyzed through anti-viral performance tests based on research and development cases of worldwide and immemorial time. he Korea Construction Research Institute (KCL) has received anti-bacterial performance certification and anti-viral test scores from the "National Approval Performance Certification Agency." At the time, NCCP 43326 Human Corona virus (BetaCoV/Korea/KCDC03/2020), which was approved by the Centers for Disease Control and Prevention, was introduced to ensure that the activity rate of infected cells was satisfied in the anti-viral performance test. Anti-proliferation measures for the Corona 19 virus require a quality clinical trial study comparing the experimental group within the glass space where the antiviral copper film is constructed with the comparator of the same condition without copper film.

Biosorption of Cadmium by a Methanotrophs Exopolysaccharide (메탄산화세균의 EPS를 이용한 Cd의 생물흡착)

  • Lee, Hee-Ja;Kim, Kwang-Soo;Cho, Yang-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1415-1419
    • /
    • 2006
  • 메탄을 탄소원 및 에너지원으로 이용하는 메탄산화균은 물질대사과정 중에 다량의 세포외 고분자물질인 Extracellular polymeric substances(EPS)를 생성하는데, EPS는 카르복실기와 같은 표면흡착 기능을 가지고 있어 생체흡착제로 사용이 가능하다. 따라서 본 연구에서는 메탄산화세균을 이용하여 중금속인 Cd의 흡착성능을 파악하여 활성슬러지의 흡착능과 비교하고, EPS 농도별, pH별 흡착량의 변화를 실험한 후 Freundlich 흡착모델식에 적용하여 흡착공정의 기본적인 설계인자를 도출하고자 하였다. 실험에 사용한 메탄산화세균은 매립지 복토층 상부 토양에서 분리하여 실험실에서 대량으로 배양하였으며, EPS 생성을 위해 메탄을 Head space의 20%를 주입하고 $30^{\circ}C$, 150rpm에서 질소원이 부족한 조건으로 48hr 동안 배양하였다. Cd의 흡착실험은 용액의 pH를 3에서 8까지 변화를 주면서 활성슬러지와 메탄산화세균의 시간별 흡착능을 측정하였다. 또한 중금속의 농도별 흡착능을 측정하여 흡착평형 상수를 파악하였으며, 중금속 흡착 전, 후 미생물의 SEM 촬영, FT-IR 분석, 전자현미분석(EPMA)을 통하여 무기성분 분석 및 표면관찰을 수행하였다. 실험결과 메탄산화세균에 의해 생성된 EPS 물질은 중금속에 대한 강한 결합능력이 있으며, Cd에 대한 최고 흡착능은 26mg Cd(Ⅱ)/g VSS의 값을 보였다. 이러한 미생물의 EPS의 흡착능은 pH와 칼슘이온의 영향을 많이 받았으며, 메탄산화세균의 FT-IR 분석결과 EPS에는 sulfate ester, pyruvate 등과 같은 작용기와 amino sugar, carboxyl 작용기들이 많이 존재하여 활성슬러지에 비해 중금속의 흡착능이 높은 것으로 사료되었다.X>${\mu}_{max,A}$는 최대암모니아 섭취률을 이용하여 구한 결과 $0.65d^{-1}$로 나타났다.EX>$60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.심볼 및 색채 디자인 등의 작업이 수반되어야 하며, 이들을 고려한 인터넷용 GIS기본도를 신규 제작한다. 상습침수지구와 관련된 각종 GIS데이타와 각 기관이 보유하고 있는 공공정보 가운데 공간정보와 연계되어야 하는 자료를 인터넷 GIS를 이용하여 효율적으로 관리하기 위해서는 단계별 구축전략이 필요하다. 따라서 본 논문에서는 인터넷 GIS를 이용하여 상습침수구역관련 정보를 검색, 처리 및 분석할 수 있는 상습침수 구역 종합정보화 시스템을 구축토록 하였다.N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전

  • PDF

In-Vitro Thrombosis Detection of Mechanical Valve using Artificial Neural Network (인공신경망을 이용한 기계식 판막의 생체외 모의 혈전현상 검출)

  • 이혁수;이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.429-438
    • /
    • 1997
  • Mechanical valve is one of the most widely used implantable artificial organs of which the reliability is so important that its failure means the death of patient. Therefore early noninvasive detection is essentially required, though mechanical valve failure with thrombosis is the most common. The objective of this paper is to detect the thrombosis formation by spectral analysis and neural network. Using microphone and amplifier, we measured the sound from the mechanical valve which is attached to the pneumatic ventricular assist device. The sound was sampled by A/D converter(DaqBook 100) and the periodogram is the main algorithm for obtaining spectrum. We made the thrombosis models using pellethane and silicon and they are thrombosis model on the valvular disk, around the sewing ring and fibrous tissue growth across the orifice of valve. The performance of the measurment system was tested firstly using 1 KHz sinusoidal wave. The measurement system detected well 1KHz spectrum as expected. The spectrum of normal and 5 kinds of thrombotic valve were obtained and primary and secondary peak appeared in each spectrum waveform. We find that the secondary peak changes according to the thrombosis model. So to distinguish the secondary peak of normal and thrombotic valve quantatively, 3 layer back propagation neural network, which contains 7, 000 input node, 20 hidden layer and 1 output was employed The trained neural network can distinguish normal and valve with more than 90% probability. As a conclusion, the noninvasive monitoring of implanted mechanical valve is possible by analysing the acoustical spectrum using neural network algorithm and this method will be applied to the performance evaluation of other implantable artificial organs.

  • PDF

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.