• Title/Summary/Keyword: 생체역학적 평가

Search Result 74, Processing Time 0.026 seconds

Design of PWM-Based Photo Irradiation System for Acne Treatment (여드름 치료를 위한 PWM 기반 광 조사 시스템 설계)

  • Kim, Chang-Su;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.207-215
    • /
    • 2012
  • As one of photo dynamic therapies, the existing LED photo irradiation method with 635 nm continuous wave has most frequently been used for acne treatment, it suffered from a low energy efficiency and generation of a large amount of heat in tissues requiring improvement measures. In this thesis, a LED photo irradiation system for acne treatment has been designed using PWM(Pulse Width Modulation) mode to enhance the energy efficiency and prevent thermal destruction in tissues. System configuration consisting largely of timer module, PWM module, and photo transfer device has been designed with the use of 1 W LED at a wavelength of 660 nm for the photo transfer device to increase skin penetration depth for treatment of acne. Frequency and wave form generated by using PWM control was verified along with confirmation of output energy of 660 nm LED and surface temperatures of tissues, followed by evaluation of stable energy outputs and stability of tissues. The results indicated that whereas power loss was high and thermal destruction in tissues was exhibited when C.W mode was used to obtain the optical energy of 1 W LED at a wavelength of 660 nm for acne treatment, realization of PWM mode allowed lowering of power consumption for LED through pulse width modulation, and no occurrence of thermal destruction in tissues, suggesting that PWM mode is safer and more effective for treatment of acne than C.W mode.

작업부하에대한 심리/환경적 영향 평가기법 개발: 제조업체를 중심으로

  • 박창순;조영진;김정룡
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.40-45
    • /
    • 1998
  • 본 연구에서는 현장 작업자 개인이 느끼는 심리/환경적 부하를 정량적으로 파악할 수 있는 척도를 개발하였다. 이러한 척도는 현장의 중간관리자들이 간단한 기구와 직접 관찰을 통해 쉽게 사용할 수 있도록 설계되었다. 심리적 작업부하 측정은 기존 연구와 현장 작업자를 대상으로 한 인터뷰 결과를 바탕으로, 타당도가 높다고 인정되는 심리부하 측정 요소를 결정하였고, 문헌과 모의 검사를 통하여 부 담감이나 편의(bias)를 줄일 수 있도록 문항수 및 어휘를 선택하였으며, 각각의 설문은 다양한 문체 중 가장 신뢰도가 높은 형태를 선정하였다. 환경적 작업부하 측정은 문헌 조사를 통하여 측정을 위한 요소를 결덩하였고, KS 규격을 기존으로 새로운 환경부하 측정 지침서를 개발하였고, 현장 예비조사가 실시되었다. 또한, 환경부하 측정결과를 지수화하기 위한 수리적 모델과, 심리적척도와의 통합을 위 한 수리적 방법론이 제시되었다. 이러한 설문 문항과 환경조사방법은 작업장을 대상으로 적용하여 실 제로 그 효용성 여부를 검토하였다. 연구 결과 이제까지 소홀히 여겨왔던 작업자의 심리적/환경적 부 하를 정량적으로 간편하게 측정할 수 있는 방법이 개발되었고, 정량화한 심리/환경 부하 척도는 이제 까지 주로 조사되었던 생체역학적/생리적 부담도와 더불어 종합적인 작업부하 평가에 일익을 담당할 것으로 예상된다. 또한, 이러한 척도에 의한 결과는 현장 근로자들의 근로여건 개선을 위하여 노/사/ 정부 모두가 만족할 수 있는 객관적 자료로 사용될 수 있으며, 예방차원의 안전관리에도 응용될 수 있 을 것으로 기대한다.구로 신체의 종합적인 만족도, 선호를 취급하고 있을 뿐 신체각 부위의 만족 도나 선호에 관한 자세한 고찰을 하고 있지 않으며 자신의 신체에 대한 인식도 및 실제체형과의 비교는 이루어지고 있지 않다. 이에, 신체 각 부위에 대한 인식도 및 실제 신체 측정치와 만족도와의 관계 및 이상형에 대해 구체적으로 파악할 필요가 있다. 또한, 신체에 대한 이상형은 시대의 여러 여건에 따라서 변화할 수 있으므로 의복 착용자가 의복을 통해서 표현하고자 하는 이상형의 시대적 변화를 살펴볼 필요가 있다. 따라서 본 연구에서는 신체에 대한 인식도 및 만족도, 이상형에 대한 설문지 조사와 신체측정을 통하여 신체 크기에대한 만족도를 객관적인 척도로 고찰하고, 이상형과 실제 체형에 관하여 고찰하고자 한다. 도한, 1992년도 자료와의 비교를 통하여 시대에 따른 신체만족도와 이상형의 변화를 파악하고자 한다. 이를 기초로 한 의복원형 제작 및 의복 디자인에 대한 연구를 통해 의복의 맞음새가 좋을뿐만 아니라 의복착용자들 에게 심리적 만족을 줄 수 있는 의복 제작에 도움이 될 수 있을 것이다.적입지로 분석되었다.등 다양한 모형들을 고려해 본 뒤, 적절한 모형을 적용할 것이다. 가로망 설계 모형에서 신호제어를 고려하기 위해서는 주어진 가로망에 대한 통행 배정과정에서 고려되는 통행시간을 링크통행시간과 교차로 지체시간을 동시에 고려해야 하는데, 이러한 문제의 해결을 위해서 최근 활발히 논의되고 있는 교차로에서의 신호제어에 대응하는 통행배정 모형을 도입하여 고려하고자 한다. 이를 위해서 지금까지 연구되어온 Global

  • PDF

A Numerical Analysis on the Hemodynamic Characteristics in Elastic Blood Vessel with Stenosis (협착이 있는 탄성혈관을 흐르는 혈액의 유동특성에 관한 수치해석적 연구)

  • 정삼두;김창녕
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.281-286
    • /
    • 2002
  • In this study, blood flow in a carotid artery supplying blood to the human's brain has been numerically simulated to find out how the blood flow affects the genesis and the growth of atherosclerosis and arterial thrombosis. Velocity Profiles and hemodynamic parameters have been investigated for the carotid arteries with three different stenoses under physiological flow condition. Blood has been treated as Newtonian and non-Newtonian fluid. To model the shear thinning properties of blood for non-Newtonian fluid, the Carreau-Yasuda model has been employed. The result shows that the wall shear stress(WSS) increases with the development of stenosis and that the wall shear stress in Newtonian fluid is highly evaluated compared with that in non-Newtonian Fluid. Oscillatory shear index has been employed to identify the time-averaged reattachment point and this point is located farther from the stenosis for Newtonian fluid than for non-Newtonian fluid The wall shear stress gradient(WSSG) along the wall has been estimated to be very high around the stenosis region when stenosis is developed much and the WSSG peak value of Newtonian fluid is higher than that of non-Newtonian fluid.

Evaluation of Landing Impact Force of Court Sport Shoes at Running by Finite Element Analysis (유한요소 해석을 통한 코트 스포츠화의 런닝시 충격력 평가)

  • Kim, Seong-Ho;Cho, Jin-Rae;Ryu, Sung-Heon;Choi, Joo-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.498-503
    • /
    • 2004
  • A fundamental function of court sport shoes has been considered as the protection of human feet from unexpected injuries. But, recently its role for improving the playing competency is being regarded as a more important function. In connection with this situation, intensive efforts are being world-widely forced on the development of court sport shoes proving the excellent playing competency, by taking kinesiology and biomechanics into consideration. However, the success of this goal depends definitely on the shoes design based upon the reliable evaluation of shoes functional parts. This paper addresses the application of finite element method to the evaluation of landing impact force of court sport shoes. In order to reflect the coupling effect between leg and shoes accurately and effectively, we construct a fully coupled shoes-leg FEM model which does not rely on the independent experimental data any more. Through the numerical experiments, we assess the reliability of the coupled FEM model by comparing with the experimental results and investigate the landing impact characteristics of court sport shoes.

  • PDF

A Study on the Prediction of Bone Remodeling of Plated-Human Femur using Stress Analysis (응력해석에 의한 골절판이 부착된 인체 대퇴골의 골재형성 예측에 관한 연구)

  • Kim, Hyun-Su
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.111-125
    • /
    • 1995
  • The stress distribution of bone is altered by the rigid bone plate, sometimes resulting in unfavorable osteoporosis. The rigidity and the biocompatibility are important factors for the design of prosthesis, however, it is also necessary to consider the effect on the bone remodeling. In this paper, it is attempted to establish an approximate and simple method to predict the trend of the configuration of surface bone remodeling upon a bone plate using stress analysis. Thus, three dimensional finite element model of plated-human femur is generated and simulated. In addition, the stress difference method (SDM) is introduced and attempted to demonstrate the configuration of surface bone remodeling of the plated-human femur.

  • PDF

Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis (전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석)

  • Park, Jun-Sung;Lee, Sang Hyun;Song, Chanhee;Ro, Jung Hoon;Lee, Chiseung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.

Evaluation for Biomechanical Effects of Metatarsal Pad and Insole on Gait (보행 중 중족골 패드와 인솔의 생체역학적 영향성 평가)

  • Choi, Jung-Kyu;Park, In-Sik;Lee, Hong-Jae;Won, Yong-Gwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.487-494
    • /
    • 2011
  • The purpose of this study was to evaluate the effects of metatarsal pad (MP) compared with barefoot and MP with using different insoles on gait. 15 healthy females who had no history of injury in the lower extremity with an average age of 22.7 year(SD=1.35), height of 160 cm(SD=3.4), weight of 48.8 kg(SD=5.52) and average foot size of 232.5 mm(SD=6.8) participated in this study as the subjects. The subjects walked on a treadmill under four different experimental conditions: 1) walking with barefoot, 2) walking wearing MP 3) walking wearing a soft insole with MP(SIMP), 4) walking wearing a rigid insole with MP(HIMP). During walking, foot pressure data such as force, contacting area, peak pressure, and mean pressure was collected using Pedar-X System(Novel Gmbh, Germany) and EMG activity of lower limb muscles such as tibialis anterior(TA), lateral gastrocnemius(LG), rectus femoris(RF), and musculus biceps femoris(MBF) was gathered using Delsys EMG Work System(Delsys, USA). Collected data was then analyzed using paired t-test in order to investigate the effects of each of experimental conditions. As a result of the analysis, when MP and HIMP were equipped, overall contacting area was increased while the force, peak pressure and the mean pressure were decreased. Especially, when the SIMP was equipped, every data were significantly decreased. In case of EMG, wearing MP, SIMP and HIMP made three muscles(TA, LG, RF)'s activity decrease. A result of the analysis will be able to apply for manufacturing functional shoes, diabetes shoes, senior shoes and lower extremity orthosis. Significance of the study due to a metatarsal pad and the insole is to analyze the changes in muscle strength.

A Preliminary study of Biomechanical Behavior of High-Performance Polymer Post-Core System (고성능 폴리머 재질의 포스트-코어 시스템의 생역학적 거동에 대한 예비실험)

  • Lee, Ki-Sun;Kim, Jong-Eun;Kim, Jee-Hwan;Lee, Jeong-Yol;Shin, Sang-Wan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.75-81
    • /
    • 2018
  • The aim of this study was to evaluate the biomechanical behavior and long-term safety of high performance polymer PEKK as an intraradicular dental post-core material through comparative finite element analysis (FEA) with other conventional post-core materials. A 3D FEA model of a maxillary central incisor was constructed. A cyclic loading force of 50 N was applied at an angle of $45^{\circ}$ to the longitudinal axis of the tooth at the palatal surface of the crown. For comparison with traditionally used post-core materials, three materials (gold, fiberglass, and PEKK) were simulated to determine their post-core properties. PEKK, with a lower elastic modulus than root dentin, showed comparably high failure resistance and a more favorable stress distribution than conventional post-core material. However, the PEKK post-core system showed a higher probability of debonding and crown failure under long-term cyclic loading than the metal or fiberglass post-core systems.

Development of Multidimensional Analysis System for Bio-pathways (바이오 패스웨이 다차원 분석 시스템 개발)

  • Seo, Dongmin;Choi, Yunsoo;Jeon, Sun-Hee;Lee, Min-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.467-475
    • /
    • 2014
  • With the development of genomics, wearable device and IT/NT, a vast amount of bio-medical data are generated recently. Also, healthcare industries based on big-data are booming and big-data technology based on bio-medical data is rising rapidly as a core technology for improving the national health and aged society. A pathway is the biological deep knowledge that represents the relations of dynamics and interaction among proteins, genes and cells by a network. A pathway is wildly being used as an important part of a bio-medical big-data analysis. However, a pathway analysis requires a lot of time and effort because a pathway is very diverse and high volume. Also, multidimensional analysis systems for various pathways are nonexistent even now. In this paper, we proposed a pathway analysis system that collects user interest pathways from KEGG pathway database that supports the most widely used pathways, constructs a network based on a hierarchy structure of pathways and analyzes the relations of dynamics and interaction among pathways by clustering and selecting core pathways from the network. Finally, to verify the superiority of our pathway analysis system, we evaluate the performance of our system in various experiments.

Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias (단일, 이중 산처리 임플란트의 회전제거력 비교)

  • Kim, Jong-Jin;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.335-341
    • /
    • 2019
  • Purpose: Chemically strong-acids (HF and $HCl/H_2SO_4$) dual etching implant surfaces have higher strengths of osseointegration than machined implant surfaces. However, the dual acid treatment deteriorates the physical properties of the titanium by weakening the fatigue resistance of the implant and causing microcracks. The removal torque comparison between the dual-acid etched (hydrochloric acid, sulfuric acid, HS) and single-acid etched implants (hydrochloric acid, H) could reveal the efficiency of implant surface acid treatment. Materials and methods: Nine $3.75{\times}4mm$ dual-acid etched SLA implants and nine single-acid etched SLA implants were inserted into New Zealand rabbit tibias. After 10 days, removal torque, roughness, and wetting angle were measured. Results: Mean removal torque values were as follows: Mean removal torque were 9.94 Ncm for HS group and 9.96 Ncm for H group (P=.995). Mean surface roughness value were $0.93{\mu}m$ for HS group and $0.84{\mu}m$ for H group (P=.170). Root mean square roughness (RSq) values were $1.21{\mu}m$ for HS group and $1.08{\mu}m$ for H group (P=.294), and mean wetting angle values were $99^{\circ}$ for HS group and $98^{\circ}$ for H group (P=.829). Statistical analysis showed no significant difference between the removal torques, roughness, or wetting angles of the two groups. Conclusion: In this experiment, we found no significant difference in removal torque, roughness, or wetting angle between dual-acid etched and single-acid etched implants.