Modeling the Controllable Parameters of Radon Environment System with Dose Sensitivity Analysis (실내 라돈환경계의 선량감도분석에 의한 제어매개변수 모델링)

  • Zoo, Oon-Pyo;Chang, Yi-Young;Kim, Kern-Joong
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.41-54
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of indoor radon $(^{222}Rn)$ and its decay products (Rn-D) by applying the input~output linear system theory. Physical behaviors of $^{222}Rn\;&\;Rn-D$ were analyzed in terms of $(^{222}Rn)$ gas -generation, -migation and -infiltration to indoor environments, and the performance output-function, i. e. mean dose equivalent to Tracho-Bronchial (TB) lung region, was assessed to the following extented ranges of the controllable paramenters; a) the ventilation rate $constant({\lambda}_v)\;:\;0{\sim}50[h^{-l}].\;b)$ the attachment rate $constant({\lambda}_a)\;:\;0{\sim}500[h^{-l}].\;c)$ the unattached-deposition rate constant (${\lambda}^u_d)\;:\;0-50[h-l]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations; a) indoor $^{222}Rn\;&\;Rn-D$ Behaviour; Jacobi-Porstendoerfer-Bruno model.

  • PDF

A Comparative Study on the Formation of Zeolite-Methane Hyudrate (제올라이트-메탄 하이드레이트 생성에 대한 비교 연구)

  • Park, SungSeek;An, EoungJin;Kim, NamJin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.145.2-145.2
    • /
    • 2011
  • 메탄 하이드레이트는 낮은 온도와 높은 압력 조건에서 물분자들의 격자구조에 메탄가스분자가 포획되어 수소결합으로 형성되는 외관상 얼음과 비슷한 결정성 화합물이다. $1m^3$의 메탄 하이드레이트는 표준상태에서 $172m^3$의 메탄가스와 $0.8m^3$의 물로 분해되며, $-10^{\circ}C{\sim}-20^{\circ}C$의 온도에서는 하이드레이트 입자표면에서 생성되는 얼음막으로 인하여 상압에서도 안정하게 존재하는 자기보존 효과를 가지고 있다. 따라서 이와 같은 특징을 천연가스 수송 및 저장의 방법으로 이용할 경우 $-162^{\circ}C$의 초저온을 만들고 유지시키기 위하여 고가의 설비를 필요로 하는 기존의 LNG 수송방법을 대체할 수 있다. 특히 연간 천연가스 소비량을 0.4 ~ 1.0 million ton으로 가정했을 때, 하이드레이트 수송방법은 LNG 수송에 비해 18 ~ 25% 정도의 비용을 절약할 수 있는 경제적인 방법으로 알려져 있다. 그러나 하이드레이트를 인공적으로 제조할 경우 물분자와 가스분자의 반응율이 낮기 때문에 하이드레이트가 생성되기까지 많은 시간이 소요되며, 하이드레이트에 포획되는 가스분자의 양도 적다. 따라서 본 연구에서는 이와 같은 문제점을 해결하기 위하여 다공성 물질인 천연 제올라이트와 제올라이트 13X를 이용하여 제올라이트 혼합유체를 제조하였으며, 메탄가스와 반응시켜 하이드레이트를 생성시키는 실험을 수행하였다. 그 결과, 하이드레이트 생성 시 천연 제올라이트와 제올라이트 13X 모두 0.01 wt%의 혼합비율에서 가장 좋은 효과를 나타내었으며, 하이드레이트에 포획된 가스의 양은 같은 과냉도 조건에서 천연제올라이트와 제올라이트 13X 혼합유체를 이용하여 하이드레이트를 생성 시켰을 때, 증류수보다 각각 4배, 5배 높음을 보였다. 또한 낮은 과냉도에서 하이드레이트 생성 시 제올라이트, 제올라이트13X 혼합유체에서 하이드레이트 생성시간이 증류수에서 하이드레이트를 생성시킬 때보다 빨라짐을 확인하였다.

  • PDF

Liquefation Characteristics of Polypropylene by Low-Temperature Pyrolysis by using Co and Mo Dispersed Catalysts under time and loading variations (Co 및 Mo 분산촉매 반응시간과 농도 변화에 따른 PP의 저온열분해 액화특성)

  • Park, Jun-Gyu;Lee, Bong-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.281-289
    • /
    • 2015
  • This study investigated the conversion of oil products from polypropylene by using dispersed Co and Mo catalyst on reaction time and concentration change for knowledging liquefation characteristics at low-temperature (425, 450 and $475^{\circ}C$) pyrolysis in a batch reactor. The reaction time was set in 20~80 minutes and the oil products formed during pyrolysis were classfied into gas, gasoline, kero, diesel and heavy oil according to the domestic specification of petroleum products. The pyrolysis conversion rate was showed as Mo catalyst > Co catalyst > Thermal in all reaction time at reaction temperature $450^{\circ}C$. The conversion rate and yields of the pyrolysis products were the most height when Co and Mo Catalyst ratio was 50:50.

Study on Methanol Conversion Efficiency and Mass Transfer of Steam-Methanol Reforming on Flow Rate Variation in Curved Channel (곡유로 채널을 가지는 수증기-메탄올 개질기에서 유량 변화에 따른 메탄올 전환율 및 물질 전달에 관한 연구)

  • Jang, Hyun;Park, In Sung;Suh, Jeong Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.261-269
    • /
    • 2015
  • In this study, numerical analysis of curved channel steam-methanol reformer was conducted using the computational fluid dynamics (CFD) commercial code STAR-CCM. A pre-numerical analysis of reference model with a cylindrical channel reactor was performed to validate the combustion model of the CFD commercial code. The result of advance validation was in agreement with reference model over 95%. After completing the validation, a curved channel reactor was designed to determine the effects of shape and length of flow path on methanol conversion efficiency and generation of hydrogen. Numerical analysis of the curved-channel reformer was conducted under various flow rate ($10/15/20{\mu}l/min$). As a result, the characteristics of flow and mass transfer were confirmed in the cylindrical channel and curved channel reactor, and useful information about methanol conversion efficiency and hydrogen generation was obtained for various flow rate.

An Analysis of Luminance Histogram and Correlation of Motion Vector for Unsuitable Frames for Frame Rate Up Conversion (프레임율 상향 변환에 부적합한 프레임들에 대한 밝기값 히스토그램과 모션 벡터 상관성 분석)

  • Kim, Sangchul;Nang, Jongho
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.10
    • /
    • pp.532-536
    • /
    • 2016
  • Frame Rate Up Conversion (FRUC) generate interpolated frames between existing frames using motion estimation and motion compensation interpolation considering temporal redundancy. Falsely-estimated FRUC, however, can generate poor quality frames because FRUC typically uses blending-based interpolation method. As skipping an interpolating process between frames generate mis-estimated motion vectors, could improve Quality of Services of FRUC. In this Paper we analyze luminance histogram and motion vector consistency in frames generating poor quality interpolated frames. We conclude these features could help to be a clue in classifying the frames, which often result in the poor quality of FRUC results through the analysis and experiment.

Manganese Oxide Catalyzed Fenton-like Reduction of Chlorinated Compounds (산화망간으로 촉매화된 펜톤유사반응을 적용한 염소계화합물의 환원분해)

  • 김상민;공성호;김용수
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.95-102
    • /
    • 2002
  • Manganese oxide/ hydrogen peroxide($MnO_2$/${H_2}{O_2}$) reactions were investigated as an alternative to Fenton-like reaction to reduce chlorinated organic compounds in groundwater This system showed high degradation of CT with low ${H_2}{O_2}$concentration($\leq$294mM) at neutral condition, and CT degradation increased with increasing pH values. The rate of CT degradation was not so much dependent on increase in $MnO_2$concentration since increase in production of oxygen during the reaction obstructed reaction of ${H_2}{O_2}$ on the surface of $MnO_2$. These results show that $MnO_2$catalyzed Ponton-like reaction could be a potential alternative method for treating chlorinated organic compounds in groundwater.

Antibacterial and anti-inflammatory effects of Platycodon grandiflorum extracts (도라지 추출물의 항균작용 및 항염작용)

  • Kim, Jung
    • Journal of Digital Convergence
    • /
    • v.12 no.3
    • /
    • pp.359-366
    • /
    • 2014
  • This study investigated the impact on S. mutans와 C. albicans in order to reveal the antimicrobial activity of Platycodon grandiflorum extracts. In addition, it examined NO generation inhibition rate in accordance with the extract concentration from Raw 264.7 cell in order to find out anti-inflammatory activation. As for the study materials, domestically made 100% Platycodon grandiflorum powder was utilized. As for the experimental strain, S. mutans KCTC 3065 and C. albicalns KCTC 7965 were utilized. Consequently, this study obtained the following results. Growth inhibition rate of S. mutans became significantly higher with higher concentration of Platycodon grandiflorum extracts. Growth inhibition rate of C. albicans became significantly higher with higher concentration of Platycodon grandiflorum extracts. NO generation inhibition rate was found to be 29.2% and 26.1% respectively when adding Platycodon grandiflorum extract with the concentration of 10 and $20{\mu}g/ml$ in Raw 264.7 cells. These results mean that Platycodon grandiflorum could be leveraged as antimicrobial and anti-inflammatory substance.

An Embedded Video Compression Scheme Using a Three-Dimensional Rate-Distortion Optimization Based Block Coder (3차원 비트율-왜곡 최적화 기반 블록 부호화를 이용하는 임베디드 비디오 압축 방법)

  • Yang, Chang Mo;Chung, Kwangsue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1155-1166
    • /
    • 2016
  • In this paper, we propose a new embedded video compression scheme which uses three-dimensional rate-distortion optimization based block coder. After the proposed scheme removes temporal redundancy by applying the motion compensated temporal filtering(MCTF) on input video frames, two dimensional discrete wavelet transform is applied on video frames to remove spatial redundancy. The three-dimensional wavelet coefficients generated in this way are sorted according to their expected rate-distortion slope and encoded by using the three-dimensional block partition coding method. The proposed scheme also uses both the effective color video coding method which maintains embedded features, and the efficient bit-rate control method. Experimental results demonstrate that the proposed scheme not only produces embedded bit-streams, but also outperforms existing video compression schemes.

Radiation Sensitivity of Some Toxigenic Molds Isolated from Deteriorated Rice (변질미(變質米)에서 분리된 독소생성(毒素生成)곰팡이의 방사선(放射線) 감수성(感受性))

  • Choi, Eon-Ho;Kim, Hong-Lyour;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.148-153
    • /
    • 1975
  • Seven toxigenic molds isolated from deteriorated rice in Korea, Aspergillus clavatus, Asp. flavus var. columnaris, Asp. fumigatus, Asp. ochraceus, Penicillium citrinum, Pen. implicatum, and Pen. islandicum, were examined for their sensitivity toward Co-60 gamma rays for survival. Conidia of all tested species showed survival curves of sigmoidal type, from which decimal reduction doses were found to vary in the range of $14{\sim}33$ krad, induction doses, in the range of $12{\sim}56$ krad and inactivation factors at 200 krad, in the range of $4.6{\sim}12.8$, all at a dose rate of 11.56 krad/min. Dose rate effects on the radiosensitivity of Asp. flavus and Pen. islandicum conidia indicated that the higher dose rate (11.56 krad/min) caused decreases in decimal reduction doses as compared with the lower dose rate (2.67 krad/min).

  • PDF

Effects of Annealing of Gas-atomized Fe-Si-Cr Powder (Fe-Si-Cr 분말합금의 열처리 효과)

  • Jang, Pyungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • Effects of annealing of the gas-atomized Fe-9%Si-2%Cr powder which is suitable for high frequency application in mobile devices because of its high electrical resistivity were studied with an emphasis on the order-disorder phase transition. The formation of B2 ordered phase could not be suppressed during atomization process. When the powder was annealed at a temperature higher than $550^{\circ}C$ the peak diffracted from $DO_3$ phase could be detected. With increasing annealing temperature lattice parameter and coercivity decreased. An interesting phenomenon was an abrupt increment of coercivity in the powder annealed at $450^{\circ}C$. Highest permeability could be shown in the powder annealed at a relative low temperature of $150^{\circ}C$ and then the permeability decreased with annealing temperature. The above-mentioned results could be successfully explained by both the formation of $DO_3$ ordered phases and the change of electrical resistivity of the Fe-Si-Cr powder which was also originated from the phase transition.