• Title/Summary/Keyword: 상향류

Search Result 88, Processing Time 0.024 seconds

Treatment of Artificial Sewage Using a Zeolite Column (제올라이트 칼럼에 의한 인공생활하수처리)

  • Seo, Jeoung-Yoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.178-188
    • /
    • 2002
  • Constructed wetlands typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. Removal efficiency was $COD_{Cr}$ 94.63% T-P 41.41% and $NH_4^+-N$ 99.75% at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of zeolites in the diameter range of 0.5 to 1 mm and 1 to 3 mm. Accordingly, hydraulic load 314 $L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixtures were used to determine the optimal mixing ratio by volume of a zeolite (A) in the diameter range of 0.5 to 1 mm to a zeolite (B) in the diameter range of 1 to 3 mm 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm $COD_{Cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. That of T-P ranged 56.42 to 58.72% and, that of T-N and $NH_4^+-N$ was 87% and 99% regardless of mixing ratios of two zeolites. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at Inter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate far Inter medium of constructed wetland Removal efficiency was higher in down-flow than in up-flow, and all contaminants were removed most in 20 cm filter height near feeding area.

A Study on the Type of Pavement Base and Drainage in Mountain Road for the Prevention of the Pavement Damage by Uplift Water Pressure (수치해석을 활용한 산지도로의 상향침투수압으로 인한 포장파손방지를 위한 포장기층종류 및 배수형태의 고찰)

  • Lim, Young-Kyu;Yune, Chan-Young;Lee, Seung-Woo
    • International Journal of Highway Engineering
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Construction of road closed to mountains is inevitable in Korea because the mountainous region in Korea is more than 70% in area. Recently, due to global warming, typhoons or heavy rainfalls frequently occur, and accordingly, mountain roads are seriously damaged by landslides, debris flows, and uplift pressure below pavement. in this study, damage on pavement by uplift pressure was investigated. Various influencing factors such as slope angle, reinforcement of slope surface, thickness of soil cover underlain by rock, and types of drainage system were considered to evaluate uplift pressure acting on the bottom of pavement. Raising of water table up to the surface of slope may depend on the duration and intensity of rainfall. It shows that the installation of subdrain can reduce the uplift water pressure. Therefore, It is concluded that the use of subdrain system is effective to decrease uplift pressure and cement treated base is more endurable than typical crushed-stone base.

High-rate Anaerobic Treatment of Landfill Leachate (매립지 침출수 처리의 고율 혐기성 처리)

  • Lee, Chae-Young;Shin, Hang-Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.136-146
    • /
    • 2007
  • Landfill leachate was successfully treated in upflow anaerobic sludge blanket (UASB) reactors regardless of the addition of granular sludge. Initial operating period was significantly reduced by the addition of granular sludge. At hydraulic retention time (HRT) of one day, chemical oxygen demand (COD) removal rates in Control and Granule reactor were maintained over 90%, respectively with organic loading rate (OLR) of $4-8kgCOD/m^3.d$. During the experiment, the inorganic precipitates were accumulated in and around the sludge, and in the wall of the reactors were formed in both reactors regardless of addition of granular sludge. Specific methanogenic activity (SMA) increased as adaptation of microorganism to the substrate and OLR were increased. The maximum SMA value of the sludge for Granule reactor was about $0.57gCOD/g{\cdot}VSS{\cdot}.d$. The SMA value was not decreased because of excessive inorganic accumulation, however, it was needed to have pre-treatment process of influent to remove the inorganic metals.

  • PDF

Anaerobic Treatment of Landfill Leachate Using a Upflow Anaerobic Sludge Blanket Reactor (UASB 반응조를 이용한 매립지 침출수의 혐기성 처리)

  • Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.4
    • /
    • pp.151-160
    • /
    • 2006
  • Anaerobic treatment of landfill leachate was studied to investigate the behaviors of pollutant and the characteristics of microorganism for 10 months. The upflow anaerobic sludge blanket (UASB) reactor achieved about 90% chemical oxygen demand (COD) removal at organic loading rates(OLR) up to $20kgCOD/m^3.d$. At higher OLR ($8-20kgCOD/m^3.d$), the propionate concentration increased, indicating that converting propionate to acetate was the rate-limiting step. Nevertheless, increase in the precipitate inside and on the surface of granules as well as on the wall of the reactor resulted in operational problems. The main inorganic precipitate in the granule was calcium compound. Although specific methanogenic activity (SMA) was not affected seriously in this study, metals had to be removed prior to anaerobic treatment so as to be free from the excessive inorganic accumulation that resulted in operational problems.

  • PDF

Constructing the Models Estimated for Speed Variation on the Merge Section in the Freeway (고속도로의 합류구간내 속도변화 추정모형 구축에 관한 연구)

  • 신광식;김태곤
    • Journal of Korean Port Research
    • /
    • v.13 no.1
    • /
    • pp.113-122
    • /
    • 1999
  • Congestion and traffic accidents occur on the merge and diverge sections in the interchange of the freeway. Studies have been conducted to reduce the traffic delay and accidents on the merge section in the freeway since 1960s. but a study was not conducted to estimate the speed variation on the merge section construct models estimated for the speed variation and suggest the appropriate measures. The purpose of this study was to identify the traffic flow characteristics on the merge section in the freeway construct the models estimated for the speed variation on the merge section in the freeway and finally establish the appropriate measure for reduction of traffic delay and accidents on the merge section in the freeway. The following results were obtained: I) Speed variations in the urban freeway appeared to be about 3.2mph, 6.5mph and 7.4mph based on the morning peak period, afternoon peak period and 24-hours period but those in the suburban freeway appeared to be about 8.0mph, 11.1mph and 10.1mph based on the same periods respectively. So different speed reduction signs need be installed to reduce delay and accidents on the merge section in the freeway based on the areas and periods as the freeway traffic management system(FTMS). ii) These models estimated for speed variation need to be studied with the changeable message sign(CMS) technique based on the real-time data so that the traffic flow could be maximized and the traffic delay and accidents be on the merge section in the freeway as more efficient freeway traffic management system(FTMS) in the near future.

  • PDF

Phenomenological Liquid Film Dryout Model for Upward Flow in Tubes and Annuli (원형 및 환상 채널에 흐르는 수직 상향류의 액막 건조 모델)

  • Hong, Sung-Deok;Chun, Se-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.201-207
    • /
    • 2001
  • We modeled the liquid film dryout(LFD) process for both tube and annulus which have uniformly heated vertical channels. We set phenomenological initial conditions in the model. The initial void fraction on the onset of the annular flow location is derived from the physical chum-to-annular flow criterion with the help of the drift-flux-model. The initial thermodynamic-equilibrium-quality is calculated by iteration with the flow quality to find the onset of the annular-flow location. Present model tends to predict very well at the lower exit quality but under-estimates at the higher exit quality. We found that the prediction error of the present model is gradually bigger as the inlet subcooling approaches near the saturation. We obtained excellent results for both tube and annulus channels as the mean of 0.97 and root-mean-square error of 11% for the number of 3883 experimental data on tubes, and of 0.96 and of 12% for 593 on annuli. The present model extended the applicable range to the relatively low exit quality region than previous LFD models.

  • PDF

Nitrogen Transport In Groundwater-Surface Water Hyporheic Zone at Brackish Lake (기수호의 지하수-지표수 혼합대 내 질소 거동 분석)

  • Seul Gi Lee;Jin Chul Joo;Hee Sun Moon;Su Ryeon Kim;Dong Jun Kim
    • Ecology and Resilient Infrastructure
    • /
    • v.11 no.2
    • /
    • pp.23-34
    • /
    • 2024
  • Sediment, aquifer materials, surface water, and groundwater from brackish Songji lake affected by salinity of seawater, were collected and a pilot scale column experiment was conducted to simulate the nitrogen transport through the hyporheic zone. Upstream experiments of groundwater displayed that groundwater containing a small amount of salt percolated into aquifers and sediments, maintaining low dissolved oxygen concentrations. In addition, partial denitrification occurred in the aquifer due to salinity and low dissolved oxygen, resulting in the accumulation of NO2-. In sediments,nitrogenous compounds were reduced due to adsorption by long residence times or microbial-mediated oxidation/reduction reactions. Downstream experiments of surface water displayed that surface water from the brackish lake, containing high concentrations of dissolved oxygen and salts, infiltrated into the sediments and aquifer, supplying high dissolved oxygen concentrations. This resulted in biological nitrification in the sediments and aquifer, which reduced nitrogen-based pollutants despite the high salt concentration in the surface water. Whereas partial denitrification at low dissolved oxygen concentrations in the upwelling mixing zone was observed by salinity and accumulated NO2-, nitrification at high dissolved oxygen concentrations in the downwelling mixing zone was not significantly affected by salinity. These results confirm that salinity in the brackish water lake has some influence on the nitrogen behavior of the hyporheic mixing zone, although nitrogen behavior is a complex combination of factors such as DO, pH, substrate concentration, and organic matter concentration.

A Study on the Optimal Operating Conditions for Removal of Nutrient Influential Substances Using Functional Media (기능성 여재를 활용한 부영양화 영양물질 제거의 최적 운전조건 연구)

  • Lee, Jong-Jun;Oh, Jong-Min;Choi, Seung-Jong;Kim, Ki-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.549-555
    • /
    • 2019
  • The purpose of this study is to ensure optimal operating conditions for improving the removal efficiency of phosphorus (P) and nitrogen (N) that are the causative agents of eutrophication by utilizing functional media. The main ingredients of the functional media used in this study are Si, Al, and Fe, SiO2, KAlSiO3O8, Al2O2·2SiO2O, H3Al2Si2O9, Fe3O4O), and berylite. To identify the maximum efficiency of the filtration process, the processing efficiency experiment was carried out according to flow method, velocity, and thickness of residual media. The flow method carried out two experiments, 50 m/day, 100 m/day, 150 m/day, 200 m/day, 250 m/day, and 20 cm, 40 cm, 50 cm, 60 cm, 80 cm of lead depth. Experiments have shown that SS, T-N, and T-P all showed higher elimination efficiency of the upflow current conditions than the downflow current conditions, and that the processing efficiency of the linearity is the highest at SS 50 m/day, T-N 150 m/day and T-P 100 m/day. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. It is considered desirable to set the top-down flow conditions and residual thickness of 60 cm and adjust the velocity of the line according to the target media for removal.

A Study on the Characteristic of Impinging Pressure Distribution in the Three Dimensional Impinging Water Jet (삼차원(三次元) 수분류(水噴流)의 충돌(衝突) 압력(壓力) 분포(分布) 특성(特性)에 관(關)한 연구(硏究))

  • Lee, J.S.;Choi, K.K.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.217-228
    • /
    • 1998
  • The purpose of this research is to investigate the characteristics of static and total pressure distribution in the upward free water jet system impinged on a downward flat plate. The rectangular nozzle was used and its contraction and aspect ratio was five and about seven respectively. Experimental conditions considered were jet velocity, distance between nozzle and flat plate, height of supplementary water. It was founded that pressure distribution on the flat plate had the Gaussian curve when the pressure at stagnation point and impinging half width were chosen as the scaling parameters. The maximum pressure was shown at the stagnation point. The central impingement velocity decreased with the increment of distance between nozzle and flat plate, and its slop of decay was similar to that of chracteristics decay region in the three-dimensional free jet.

  • PDF

Water Quality Improvement of Stagnant Water using an Upflow Activated Carbon Biofilm Process and Microbial Community Analysis (상향류 활성탄 생물막 공정을 이용한 정체 수역 수질 개선 및 공정 내 미생물 군집 해석)

  • Oh, Yu-Mi;Lee, Jae-Ho;Park, Jeung-Jin;Choi, Gi-Choong;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.23-32
    • /
    • 2010
  • The capacity of natural purification was limited by the interruption of natural flow and the problems such as eutrophication were occurred by nutritive salts accumulation in stagnant stream. Moreover, the inflow of non-point sources causes non-degradable materials to increase in stagnant stream. In this study, an upflow biological activated carbon (BAC) biofilm process comprised of anoxic, aerobic 1, and aerobic 2 reactors were introduced for treatment of stagnant stream and SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, and TP were monitored in the upflow BAC biofilm reactors with continuous cycling. In order to simulate stagnant stream, the lake water of amusement park and golf course were stored as influent in a tank of $2m^3$ and hydraulic retention time (HRT) was changed into 6, 4, and 2 hours. At HRT 4hr and the lake water of amusement park as influent, the removal efficiencies of SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, and TP showed the best water quality improvement and were 69.8, 83.0, 91.3, 74.1, 74.7, and 88.9%, respectively. At HRT 4hr and the lake water of golf course as influent, the removal efficiencies of SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN and TP were 78.5, 78.0, 80.2, 74.9, 55.6 and 97.5%, respectively. As the results of polymerase chain reaction - denaturing gel gradient electrophoresis (PCR-DGGE), microbial community was different depending on influent type. Fluorescence in situ hybridization (FISH) showed that nitrifying bacteria was dominant at HRT 4 hr. The biomass amount and microbial activities by INT-DHA test were not decrease even at lower HRT condition. In this study, the upflow BAC biofilm process would be considered to the water quality improvement of stagnant stream.