• Title/Summary/Keyword: 상하 좌우 복합유동

Search Result 4, Processing Time 0.019 seconds

A Study on Design of an Effective Micromixer using Horizontal and Vertical Multi-mixing (HVM) Flow Motion (상하좌우 복합유동 유도를 통한 고효율 HVM 마이크로 믹서 설계에 관한 연구)

  • Yoo, Won-Sui;Kim, Sung-Jin;Kang, Seok-Hoon;Kim, Pan-Guen;Park, Sang-Hu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.751-757
    • /
    • 2011
  • Subminiature devices such as Lab-on-a-chip and p-TAS(Micro Total Analysis System) have been intensively studied in biotechnology and chemistry, In many cases, a micromixer was widely used to mix different solutions for synthesizing novel materials. However, in microfluidic system, there is generally a laminar flow under very small Reynolds number so it is difficult to mix each solution perfectly. To settle this problem, we propose a new mixing mechanism which generates a horizontal and vertical multi-mixing (HVM) flow for effective mixing within a short mixing section. We evaluated the proposed mechanism using CFD analysis, and the results showed that the HVM mechanism had a relative high-effectiveness comparing to the existing methods.

Fabrication and Performance Evaluation of the HVM Micromixer using Horizontal and Vertical Multi-mixing (HVM) Flow Motion (상하좌우 복합유동 HVM 마이크로 믹서 제작 및 성능평가)

  • Yoo, Won-Sul;Kim, Seong-Jin;Kang, Seok-Hoon;Lee, Dong-Kyu;Go, Jung-Sang;Park, Sang-Hu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.214-221
    • /
    • 2012
  • Recently, the biochip which is a prime representation of NT, IT, BT, as an example of convergence technology, has been frequently mentioned. With the recent rapid advance in biotechnology, these compact devices, such as lab-on-a-chip or u-TAS, have been developed, and more research is needed. These compact devices typically use the micro-channel in order to shed or detach and mix a variety of materials. Specially, in micro-fluidic systems, a mixer is necessary to produce a mixture because only laminar flow occurs at a low-Reynolds number. To solve this problem, HVM a micromixer that induces a horizontal and vertical multi-mixing flow motion, is proposed. The mixing performance was analyzed and verified by optimizing the shape through the CFD analysis and evaluating the structural analysis and the soundness with material properties that are obtained through the basic experiment.

Occurrence and Morphological Characteristics of the Peperite in Mt. Juwang, Cheongsong (청송 주왕산 페퍼라이트의 산출상태 및 형태학적 특징)

  • Woo, Hyeon Dong;Jang, Yun Deuk
    • Economic and Environmental Geology
    • /
    • v.47 no.2
    • /
    • pp.97-105
    • /
    • 2014
  • Peperite exposed along the Dajeonsa basalt in Mt.Juwang, Cheongsong emerged as a consequence of the simultaneity of volcano-sedimentary sequences. This study aims to classify peperites as morphological characteristics and infer the formation process by the field investigation, image analysis, X-Ray Diffractometer and polarization microscope for the magma-sediment interaction mechanism and paleoenvironment. As a result of the field investigation globular(fluidal) peperite is the representative feature at the bottom of Dajeonsa basalt, sub-angular peperite at the middle and irregular peperite at the top. Peperite domains range from sheet and pod or feeder conduit. Although the study that the morphologies of peperite are controled by the sorts of sediment and lava or magma has tended to center around the peperite, the study addresses not single mechanism but the multi-stage mechanism because Mt.juwang peperite, under the same conditions, varies in shapes and sizes and also the ratio of sediments that show the most change of the peperite affects to the formation of peperite.