• Title/Summary/Keyword: 상용전원

Search Result 205, Processing Time 0.042 seconds

A Study on the Electric Shock due to Submerged Power Source (침수 상용전원에 의한 감전위험성 검토)

  • Jung, Jong-Wook;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.71-76
    • /
    • 2007
  • This paper describes a risk assessment of electric shock based on a experiment which demonstrates a submerged commercial power source. For the experiment a water tank was made and an outlet was installed on an interior wall. After filling the tank with a conductive water solution, the electric potential was measured with the distance, the direction from the power source, the conductivity and the level of the water solution. As a result, the potential distribution due to the outlet energized and exposed to the water solution depends on the distance from the submerged power source, however, the direction from the power source, the conductivity and the level of the water solution seemed to scarcely affected on the electrical shock risk.

Active Power Filter Type Uninterruptible Power Supply (UPS) (전력용 능동필터형 무정전 전원장치)

  • 김제홍;최재호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.100-105
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply (UPS) with the performance of active power filter which compensates the harmonics and reactive power. With only one power stage, it is working simultaneously as the AC/DC rectifier/battery charger and DC/AC inverter to the operation of battery charging or back-up power supplying. Therefore the operation of the proposed system can be divided into the modes, such as the active power filter mode and the battery back-up power mode. And a novel closed-loop control strategy is used to calculate the reference current. The performance of the proposed 5[kVA] system is verified by the simulation and experimental results.

  • PDF

The Study of Single Phase Source Stability consider for the DSC Cell s Operation Character (DSC Cell의 동작특성을 고려한 단상 전원의 안정화 연구)

  • Park, Sung-June;Park, Hae-Young;Jeon, Jin-An;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1719-1721
    • /
    • 2005
  • 현재 지구 환경 오염에 관한 관심이 증가하면서, 공해가 없는 자연 에너지원에 대한 연구가 많이 진행되고 있다. 그 중에서도 태양전지 분야중 염료감응형 태양전지(DSC)는 Si계 태양전지와 비교하여 낮은 제조비용등 여러 가지 이유로 최근 많은 연구가 진행되고 있다. 따라서 DSC 발전 시스템의 효율 향상이 요구된다. 본 연구에서는 태양전지 분야 중에서 독립적인 발전설비가 필요한 도서 및 산간 지역에 전력을 안정적으로 공급할 수 있는 소형발전용의 설비로 "전압 및 전류의 피드백을 통한 DSC Cell의 독립전원의 안정화"에 관해 연구하였다. DSC Cell측의 DC입력을 받아 Boost Converter로 승압 후 Full Bridge 인버터를 사용하여 단상 220V 60Hz의 상용전원으로 변환하였다. 여기서는 32Bit 마이크로프로세서인 DSP TMS320F2812의 A/D변환기능을 이용하여 Boost Converter의 스위칭과 Full Bridge 인버터의 스위칭을 제어하였다. 특히 TMS320F2812의 RTC(Real Time Clock)를 이용하여 출력전압의 안정성 향상에 주목적을 두었다. 실험결과 출력단에서는 220V 변동범위 0.2% 주파수 60Hz의 상용전원을 얻었으며, 프로그램의 개선을 통하여 출력전압의 변동범위를 감소시켜야 될 것이다.

  • PDF

High Efficiency Power Supply for Plasma Reaction of Flexible Electrode (유연전극의 플라즈마 반응을 위한 고효율 전원장치)

  • Kwak, Bongwoo;Kim, Myungbok
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.118-119
    • /
    • 2019
  • 본 논문은 유연전극의 플라즈마 반응을 위한 고효율 전원장치에 대한 연구이다. 유연전극은 저온 플라즈마 방전으로, 수 kV의 AC형태의 고전압 및 소전력 구동 사양이 요구된다. 상용전원을 사용하는 유연전극용 고전압 전원장치는 AC-DC, DC-AC로 변환이 가능한 2단 구조를 갖는다. 1단은 낮은 전력에서 높은 효율을 달성 할 수 있는 CrM(Critical Conduction Mode) PFC와 전부하 영역 소프트 스위칭을 통해 고효율 달성이 용이한 LLC 공진 컨버터를 사용하였다. 유연전극은 사양에 따라 커패시턴스가 달라진다. 따라서, 본 논문에서는 유연전극 사양에 따른 공진 주파수의 최적화를 통해서 유연전극의 플라즈마 반응 및 특성 시험을 위해 고효율 전원장치를 구성하였다. 실험을 통해서 유연전극용 고효율 전원장치를 검증하였다.

  • PDF

The Effect of pulse power in the non-thermal plasma reactor for Hydrogen generation (수소발생용 비열플라즈마 반응기에서의 펄스파워 영향)

  • Kim, Jong-Seok;Park, Jae-Youn;Han, Sang-Bo;Jung, Jang-Gun;Koh, Hee-Seok;Park, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.548-549
    • /
    • 2005
  • 본 논문에서는 인가 전극구조가 다른 두가지 형태의 아크성 스트리머 방전용 플라즈마 반응기를 설계 제작하였다. 제작된 반응기에 60 Hz상용전원과 펄스파워를 인가전원으로 사용하여 반응기 형태와 인가전원에 따른 수소발생 특성에 대하여 조사하였다. 또한 방전 전력에 따른 수소발생량을 비교 분석하였다. 수소 발생을 위한 효과적인 수표면 방전은 강한 전계 집중과 높은 에너지 밀도를 동반한 아크성 스트리머 방전 분위기 형성이 필요하다. 인가전원으로 상용전원을 이용한 경우보다 펄스파워를 사용한 경우와 강한 전계집중 증대를 위해 인가 전극이 석영관 내에 배치된 전극 구조에서 수소발생에 효과적이였다.

  • PDF

Developement of Electrical Load Testing System Implemented with Power Regenerative Function (회생전력 기능을 갖는 전기부하시험장치 개발)

  • Do, Wang-Lok;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 2016
  • The electrical load testing system developed from this study was designed to control rated-capacity-testing or variable-load-testing in an active and precise manner and save electric energy during testing, and also to convert the saved electric energy through the electrical load testing system to grid line. As for the device under testing, it was designed to be applied to not only transformer, rectifier, voltage regulator, inverter which require grid voltage source but, also applied to electric power, aerogenerator, photovoltaic, hybrid generator, battery, etc. which do not require grid voltage source. The system was designed to return the power consumed during the testing to the grid line by connecting the synchronizing pwm inverter circuit to the grid voltage source, and was also made to enable the being-tested system from disuse of approximately 93.4% energy when compared to the conventional load testing system which has used the passive resistor.

A Study on Lighting Emergency Lamp using Photovoltaic Generation System (태양광발전시스템을 이용한 유도등용 헝광램프의 점등에 관한 연구)

  • 이상집;성낙규;이승환;오봉환;백동현;이훈구;한경희
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.22-26
    • /
    • 2000
  • Emergency lamp is installation usage on an emergency situation or firing. It's an offer at least of brightness. It's lighting to common source usually. It's transferred to reserve battery on power stoppage. This emergency lamp is lighted from solar cell system. The solar cell should be operated at the maximum power point. This paper proposes the new control method that half-bridge inverter using the solar cell can operate emergency lamp.

  • PDF

A study on sensorless driving for a BLDC motor using a common AC source (상용 교류 전원을 이용한 BLDC 모터의 센서리스 구동에 관한 연구)

  • Kim, Seong-Tae;Hong, Sun-Ki;Kang, Tae-Sam
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.242-244
    • /
    • 2001
  • 본 논문에서는 널리 사용되고 있는 BLDC 모터의 센서리스 구동에 관한 연구를 수행한다. 이 시스템은 크게 모터 구동회로와 역기전력 측정 회로, 마이크로 컴퓨터회로로 구성된다. 모터 구동회로는 상용전원을 별도의 변압기 없이 그대로 이용하여 모터에 전원을 인가하며, 역기전력 측정 회로는 센서리스 구동에 반드시 필요한 회전자의 위치 검출을 하게 되며 이를 위하여 센서 대신 회전자 위치 검출 역할을 하는 능동필터를 설계하도록 한다. 마이크로 컴퓨터는 필터로부터 얻어진 회전자 위치 신호를 이용하여 모터 구동을 위한 PWM을 발생시키며 전체적인 시스템 구동을 하게 된다.

  • PDF

DC Characteristics Analysis of Various AC loads for Hybrid Distribution (하이브리드 급전을 위한 다양한 가정용 교류부하의 직류특성연구)

  • Lee, Young-Jin;Han, Dong-Ha;Choi, Jung-Muk;Jeong, Byong-Hwan;Kim, Dong-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • Recently, the use of DC power increased due to the increased use of digital load. Power factor of input current decrease and input current harmonics increase, and conversion loss which is occurred in the AC / DC converter is a problem to provide the proper DC voltage to the device equipped with an internal AC / DC converter. Hybrid system supplies the AC power and DC power to AC load (motor load and the transformer load) and DC loads (computers, TV, LED fluorescent light) at the same time it supplies the renewable energy and utility energy taken power from Utility to user for improving the efficiency and renewable energy improvements in ease of use. This paper studies DC characteristics of traditional AC load for Hybrid distributions.

Design Considerations for Communication Systems and Power Systems for Seismic Data Acquisition (지진관측자료 수집을 위한 정보통신망과 전력체계의 요건)

  • Yoo, Sehoon;Song, Sehyun;Kim, Kichul;Choi, Seong Jong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.167-168
    • /
    • 2011
  • 한반도 및 근해의 지진 지진해일 감시를 위해 지진관측망이 구축되어 있다. 이러한 지진관측망는 향후 조기경보를 위해 보다 조밀하게 설치될 예정이다. 지진계측기의 정보통신망은 대부분 행정망 및 전용회선 단일망으로 운영되고 있으며 지진계측기의 전력체계는 상용전원의 단일 전력체계로 운영되고 있다. 국내 지진관측망 운영상의 문제점으로 단일 정보통신망 운영으로 인한 통신 단절 발생 시 지속적인 자료 수집 불능과 단일 전력체계인 상용전원 단절시 통신장비에 전원공급 단절로 인한 실시간 자료 전송 장애 발생이 있다. 또한 지진관측기의 정보통신망과 전력체계에 대한 원격감시 및 관리 기능이 부재하여 유지 보수 및 안정적 자료수집에 취약점을 가지고 있다. 이러한 취약점을 극복하기 위해서는 각종 재해에 대한 내재해성과 유지보수성을 향상시키는 것이 시급하며 정보통신망과 전력체계의 다중화/이중화가 좋은 대안이 될 수 있다.

  • PDF