• Title/Summary/Keyword: 상아질 두께

Search Result 110, Processing Time 0.027 seconds

Detection of Hidden Proximal Caries using Q-ray view in Primary Molars (Q-ray view를 이용한 유구치의 숨은 인접면 우식증 탐지)

  • Jeong, Younwook;Lee, Hyoseol;Choi, Hyungjun;Lee, Jaeho;Choi, Byungjai;Kim, Seongoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.209-217
    • /
    • 2015
  • The purpose of this study was to evaluate the ability of Q-ray view (All-in-one Bio, Seoul, Korea) in detection of proximal caries in primary molars with sound marginal ridges. Thirty two children aged 3-9 years (average $5.6{\pm}1.3$ years old) were chosen, and two examiners evaluated 100 proximal surfaces of primary molars with sound marginal ridges. The teeth were examined with; (a) visual examination, (b) Q-ray view, (c) DIAGNOdent (KaVo, Biberach, Germany) and (d) digital periapical radiography. Kappa statistic was used to assess the agreement between each examination method and the degree of caries progression. The kappa values for enamel caries were 0.15 (visual examination), 0.10 (Q-ray view), 0.25 (DIAGNOdent) and 0.68 (digital periapical radiography). The kappa values for dentinal caries were 0.34 (visual examination), 0.56 (Q-ray view), 0.44 (DIAGNOdent) and 0.70 (digital periapical radiography). Although Q-ray view showed low diagnostic ability in detection of enamel caries, it was effective in detection of hidden proximal caries extended into dentin. Q-ray view would be a useful and simple device which could aid pediatric dentists in detection of hidden proximal caries in primary molars especially when examining uncooperative children or disabled persons.

Detecting of Proximal Caries in Primary Molars using Pen-type QLF Device (펜-타입 QLF 장비의 임상적 유구치 인접면 우식 탐지 성능)

  • Cho, Hyejin;Kim, Hyuntae;Song, Ji-Soo;Shin, Teo Jeon;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.405-413
    • /
    • 2021
  • The purpose of this in vivo study was to assess the clinical screening performance of a quantitative light-induced fluorescence (QLF) device in detecting proximal caries in primary molars. Fluorescence loss, red autofluorescence and a simplified QLF score for proximal caries (QS-proximal) were evaluated for their validity in detecting proximal caries in primary molars compared to bitewing radiography. Three hundred and forty-four primary molar surfaces were included in the study. Carious lesions were scored according to lesion severity assessed by visual-tactile and radiographic examinations. The QLF images were analyzed for two quantitative parameters, fluorescence loss and red autofluorescence, as well as for QS-proximal. For both quantitative parameters and QS-proximal, the sensitivity, specificity and area under receiver operating curve (AUROC) were calculated as a function of the radiographic scoring index at enamel and dentin caries levels. Both quantitative parameters showed fair AUROC values for detecting dentine level caries (△F = 0.794, △R = 0.750). QS-proximal showed higher AUROC values (0.757 - 0.769) than that of visual-tactile scores (0.653) in detecting dentine level caries. The QLF device showed fair screening performance in detecting proximal caries in primary molars compared to bitewing radiography.

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES (복합레진의 exponential 중합법이 상아질접착제의 미세인장접착강도에 미치는 영향)

  • Seong, So-Rae;Seo, Duck-kyu;Lee, In-Bog;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.125-133
    • /
    • 2010
  • Objectives: Rapid polymerization of overlying composite resin causes high polymerization shrinkage stress at the adhesive layer. In order to alleviate the shrinkage stress, increasing the light intensity over the first 5 seconds was suggested as an exponential curing mode by an LED light curing unit (Elipar FreeLight2, 3M ESPE). In this study, the effectiveness of the exponential curing mode on reducing stress was evaluated with measuring microtensile bond strength of three adhesives after the overlying composite resin was polymerized with either continuous or exponential curing mode. Methods: Scotchbond Multipurpose Plus (MP, 3M ESPE), Single Bond 2 (SB, 3M ESPE), and Adper Prompt (AP, 3M ESPE) were applied onto the flat occlusal dentin of extracted human molar. The overlying hybrid composite (Denfil, Vericom, Korea) was cured under one of two exposing modes of the curing unit. At 48h from bonding, microtensile bond strength was measured at a crosshead speed of 1.0 mm/min. The fractured surfaces were observed under FE-SEM. Results: There was no statistically significant difference in the microtensile bond strengths of each adhesive between curing methods (Two-way ANOVA, p > 0.05). The microtensile bond strengths of MP and SB were significantly higher than that of AP (p < 0.05). Mixed failures were observed in most of the fractured surfaces, and differences in the failure mode were not observed among groups. Conclusion: The exponential curing method had no beneficial effect on the microtensile dentin bond strengths of three adhesives compared to continuous curing method.

Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations (Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석)

  • Lee, Sang-Ik;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.222-233
    • /
    • 2007
  • One of the most important and basic test of dental restorative materials is the evaluation of microleakage into the tooth-restorative interface. There are many techniques to test microleakage, but most of them have several disadvantages. Recently developed microtomography(micro-CT) can provide the three dimensional image and information about the internal component in non-destructive way, therefore using micro-CT, it is possible to evaluate microleakage exactly in quantitative manner. The purpose of this study is to find a new method for quantitative and non-destructive evaluation of microleakage in composite resin restorations using micro-CT and to compare the new method with conventional dye penetration method. Thus, microleakages of two kinds of dentin bonding systems were evaluated with above two methods. 40 extracted sound human premolars were randomly divided into two groups consisting of 20 samples and restored accordingly. Group 1 : Class V resin restorations with $Adper^{TM}$ Singe Bond Group, 2 : Class V resin restorations with $Adper^{TM}\;Promp^{TM}$ L-pop. The $Filtek^{TM}$ Supreme was applied to the Class V cavities of all teeth. After that, 10 teeth from each group were applied to evaluation of microleakage using micro-CT, and other 10 teeth from each group were using conventional dye penetration method. The conclusions of this study were as follow : 1 Using micro-CT, Group 1 showed significantly less microleakage than Group 2 and there was statistically significant difference(p<0.01) between two groups. 2. Using conventional dye penetration method, Group 1 leaked less than Group 2 and there was statistically significant difference(p<0.01) between two groups 3. The difference between two groups is more evident in the method using micro-CT. 4. In all two methods, microleakage appeared more into the cavities to dentinal margins than enamel margins.

  • PDF

The effects of short-term application of calcium hydroxide on dentin fracture strength (단기간의 수산화 칼슘 적용이 상아질 파절강도에 미치는 영향)

  • Shin, Eun-Jung;Park, Yeong-Joon;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, In-Nam;Oh, Won-Mann;Hwang, Yun-Chan
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.425-430
    • /
    • 2011
  • Objectives: This in vitro study investigated whether short-term application of calcium hydroxide in the root canal system for 1 and 4 wk affects the fracture strength of human permanent teeth. Materials and Methods: Thirty two mature human single rooted mandibular premolars in similar size and dentin thickness without decay or restorations were hand and rotary instrumented and 16 teeth vertically packed with calcium hydroxide paste and sealed coronally with caviton to imitate the endodontic procedure and the other 16 teeth was left empty as a control group. The apicies of all the samples were sealed with resin, submerged in normal saline and put in a storage box at $37^{\circ}C$ to mimic the oral environment. After 1 and 4 wk, 8 samples out of 16 samples from each group were removed from the storage box and fracture strength test was performed. The maximum load required to fracture the samples was recorded and data were analysed statistically by the two way ANOVA test at 5% significance level. Results: The mean fracture strengths of two groups after 1 wk and 4 wk were similar. The intracanal placement of calcium hydroxide weakened the fracture strength of teeth by 8.2% after 4 wk: an average of 39.23 MPa for no treatment group and 36.01 MPa for CH group. However there was no statistically significant difference between experimental groups and between time intervals. Conclusions: These results suggest that short term calcium hydroxide application is available during endodontic treatment.

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone (네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력)

  • Choi, Seok-Dong;Jin, Myoung-Uk;Kim, Ki-Ok;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.446-453
    • /
    • 2004
  • The aim of this study was to evaluate the shaping abilities of four different rotary nickel-titanium instruments with anticurvature motion to prepare root canal at danger zone by measuring the change of dentin thickness in order to have techniques of safe preparation of canals with nickel-titanium files. Mesiobuccal and mesiolingual canals of forty mesial roots of extracted human lower molars were instrumented using the crown-down technique with ProFile, $GT^{TM}$ Rotary file, Quantec file and $ProTaper^{TM}$. In each root, one canal was prepared with a straight up-and-down motion and the other canal was with an anticurvature motion. Canals were instrumented until apical foramens were up to size of 30 by one operator. The muffle system was used to evaluate the root canal preparation. After superimposing the pre- and post-instrumentation canal. change in root dentin thickness was measured at the inner and outer sides of the canal at 1. 3, and 5 mm levels from the furcation. Data were analyzed using two-way ANOVA. Root dentin thickness at danger zone was significantly thinner than that at safe zone at all levels (p < 0.05). There was no significant difference in the change of root dentin thickness between the straight up-and-down and the anticurvature motions at both danger and safe zones in all groups (p > 0.05). ProTaper removed significantly more dentin than other files especially at furcal 3 mm level of danger and safe zones (p < 0.05) Therefore, it was concluded that anticurvature motion with nickel-titanium rotary instruments does not seem to be effective in danger zone of lower molars.

RADIOPACITY COMPARISON OF TOOTH COLORED RESTORATIVE MATERIALS WITH DIGITAL RADIOGRAPHY (디지털 방사선사진술을 이용한 치아색 수복물의 방사선불투과도 비교)

  • Kim, Hyo-Jung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.499-508
    • /
    • 2000
  • The purposes of this study were to evaluate the validity of 2 kinds of digital radiography techniques in evaluating the radiopacity comparison of restorative materials and to determine the relative radiopacities of several kinds of compomer and flow able resin using these techniques. After taking radiographs of an aluminum step wedge, con-elation of optical density calibration curves were evaluated between conventional radiography with transmission densitometer and CD-Dent digital radiography (storage phosphor system) and between conventional one and RVG$^{(R)}$ digital radiography (CCD system). Compomers such as Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Dyract flow$^{(R)}$, and flowable resins such as Ultraseal-XT$^{(R)}$ plus$^{TM}$, Revolution$^{TM}$, Aeliteflo$^{TM}$ and Tetric-flow$^{(R)}$ were used. Five specimens of 5mm in diameter and 2 mm thick were fabricated with each material. Radiopacities of the materials were measured using the above radiographic techniques and compared. The results were as follows: 1. When the optical density calibration curves were compared, conventional radiography and both CD-Dent and RVG$^{(R)}$ digital radiographies showed very high inverse correlations (${\gamma}$=-0.95, ${\gamma}$=-0.98 ; p<0.05). 2. All the tested restorative materials showed levels of radiopacity the same as or greater than that of dentin (p<0.05), Radiopacities of Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Tetric flow$^{(R)}$ were greater than those of Revolution$^{TM}$, Aeliteflo$^{TM}$, or dentin (p<0.05). 3. Radiopacities of Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Tetric flow$^{(R)}$ were shown to be greater than that of enamel when conventional radiography and CD-Dent digital radiography were used (p<0.05). Radiopacity of Dyract flow$^{(R)}$ was shown to be greater than that of Enamel when conventional radiography was used (p<0.05).

  • PDF

TREATMENT OF DOUBLE TOOTH IN MANDIBULAR LATERAL INCISORS (하악 영구 측절치 Double tooth의 치험례)

  • Kim, Sang-Bae;Lee, Kwang-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.383-387
    • /
    • 2000
  • Fusion is defined as union of two separate tooth buds at some stage in their development with confluence of dentin and characterized by separate root canal and large single crown, while gemination is defined as an attempt of the single tooth bud to incompletely divide and usually result in a single root with one root canal and two completely or incompletely separated crowns. It is sometimes difficult to decide whether an abnormally large tooth is the result of fusion of a normal and a supernumerary tooth, or of gemination; use of the term 'Double tooth' may make the clinicians avoid this difficulty(Brook & Winter). Commonly there are no symptoms, but the problems associated with these anomalies include esthetics, possible loss of arch length and delayed or ectopic eruption of the permanent teeth, caries along the line of demarcation, and periodontal disease. Commonly, it dose not need to be treated in primary dentition but in case of permanent dentition, it may be requested to be treated due to esthetics and other problems. In our case, a 8 years old girl showed a Double tooth, we attained the favorable results by performing hemisection with apexification.

  • PDF

Influence of Sodium Hypochorite & EDTA on the Microtensile Bond Strength of Ethanol Wet Bonding (Ethanol Wet Bonding에서 NaOCl과 EDTA가 결합강도에 미치는 영향)

  • Kim, Deok-Joong;Song, Yong-Beom;Park, Sang-Hee;Kim, Hyoung-Sun;Lee, Hye-Yoon;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • Sodium hypochlorite and ethylene diamine tetra acetic acid are substances usually used during endodontic treatment. Several studies found that the bonding was negated with certain irrigants and some of the used irrigants have demineralizing and chealating effects, so it was advocated to omit the etching step in etch and rinse adhesive systems. The purpose of this in vitro study was to evaluate the influence of NaOCl & EDTA on the bonding strength of ethanol wet bonding. Thirty human molars were selected and mesiodistally sectioned into halves, thus providing sixty specimens. The specimens were randomly assigned to 4 groups(n=15) according to the irrigant regimen used : (1) irrigated with distilled water for 10min (control); (2) irrigated with 5.25% NaOCl(10min), flushed with 5.25% NaOCl(1min) (3) irrigated with 5.25% NaOCl, flushed with 17% EDTA (4) irrigated with 5.25% NaOCl, flushed with 17% EDTA. Each group was acid-etched with 37% phosphoric acid(except group 4) and had their dentin surfaces dehydrated with ethanol solutions : 50%, 70%, 80%, 95%, 3x100%, 30s for each application. After dehydration, a primer( 50% all bond 3 resin + 50% ethanol) was used, followed by the adhesive(ALL-BOND 3 RESIN) application. Resin composite build-ups were then prepared using an incremental technique. Specimens were sectioned into beams and submitted to a tensile load using a Micro Tensile Tester(Bisco Inc.). The data were statistically analyzed using one-way ANOVA and Tukey HSD at p<0.5 level. There was no significant difference on G1(control) and G2(irrigated with NaOCl only ). (p>0.05). G3(flushed with EDTA) showed significantly high tensile bonding strength compared to the G2 (p<0.05). G4( treated with EDTA but no acid-etching) was significantly lower value than G3. (p<0.05) Although there was no significant difference, 5.25% NaOCl seemed to have an adverse effect on the bonding strength of ethanol wet bonding. The flushing with EDTA after NaOCl irrigation prevents the decrease of bonding strength. The use of 17% EDTA as a final flush can enhance the bonding strength but EDTA flushing can't substitute for a acid-etching.