• Title/Summary/Keyword: 상시조사

Search Result 214, Processing Time 0.029 seconds

Missing Data Imputation Using Permanent Traffic Counts on National Highways (일반국토 상시 교통량자료를 이용한 교통량 결측자료 추정)

  • Ha, Jeong-A;Park, Jae-Hwa;Kim, Seong-Hyeon
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.1 s.94
    • /
    • pp.121-132
    • /
    • 2007
  • Up to now Permanent traffic volumes have been counted by Automatic Vehicle Classification (AVC) on National Highways. When counted data have missing items or errors, the data must be revised to stay statistically reliable This study was carried out to estimate correct data based on outoregression and seasonal AutoRegressive Integrated Moving Average (ARIMA). As a result of verification through seasonal ARIMA, the longer the missed period is, the greater the error. Autoregression results in better verification results than seasonal ARIMA. Traffic data is affected by the present state mote than past patterns. However. autoregression can be applied only to the cases where data include similar neighborhood patterns and even in this case. the data cannot be corrected when data are missing due to low qualify or errors Therefore, these data shoo)d be corrected using past patterns and seasonal ARIMA when the missing data occurs in short periods.

Shallow Shear-wave Velocities Using the Microtremor Survey Method (상시미동 측정을 통한 천부 횡파속도 연구)

  • Hwang, Yoon-Gu;Kim, Ki-Young
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.381-392
    • /
    • 2006
  • The passive surface wave survey using microtremor is conducted in areas of crystalline rock basements to obtain average shear-wave velocity structures to 30 m deep (Vs30), on which the earthquake-resistant design standard is based. Test data were recorded at two sites with triangular and L-shaped arrays for 4 seconds with an sampling interval of 2 ms. The microtremor recorded at a site were analysed using the spatial autocorrelation method to obtain phase-velocity spectra and effects of major factors such as size and shape of away and number of record and receiver were examined. At the other site, shear-wave velocities were derived from VSP and microtremor data separately. The results from these two methods agree to each other reasonably well, indicating that the microtremor method can be an effective geophysical tool to measure Vs30.

The Outlier-Filtering Algorithm for National Highway Continuous Traffic Counts Data (일반국도 상시조사 교통량 자료의 이상치 판정 알고리즘 개발)

  • Shin, Jae Myong;Lee, Sang Hyup;Kim, Hyun Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.691-702
    • /
    • 2013
  • In this study the quantitative outlier-filtering algorithm has been developed using the smoothing method based on the day-of-the-week traffic volume variation pattern and then, in order to test the effectiveness of the algorithm, it has been used to identify outliers from the traffic volume data collected at 14 continuous traffic counts sites on the national highways in the year 2010. The test results are satisfactory since the filtering rate is 98.2% for normal days and the mis-filtering rate is 8.0% for abnormal days. Therefore, the algorithm will be able to be used for roughly-but-quickly filtering outliers from the collected traffic volume data.

Finding Optimal Installation Depth of Strong Motion Seismometers for Seismic Observation (지진 관측을 위한 최적 설치심도 조사 방법 연구)

  • Seokho Jeong;Doyoon Lim ;Eui-Hong Hwang;Jae-Kwang Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.2
    • /
    • pp.31-40
    • /
    • 2023
  • We installed temporary strong motion seismometers at the ground surface, 1 m, 2 m, and 9 m at an existing seismic station that houses permanent seismometers installed at 20 m and 100 m, to investigate the influence of installation depth on the recorded ambient and anthropogenic noise level and the characteristics of earthquake signals. Analysis of the ambient noise shows that anthropogenic noise dominates where vibration period T < 1 s at the studied site, whereas wind speed appears to be strongly correlated with the noise level at T > 1 s. Frequency-wavenumber analysis of 2D seismometer array suggests that ambient noise in short periods are predominantly body waves, rather than surface waves. The level of ambient noise was low at 9 m and 20 m, but strong amplification of noise level at T < 0.1 s was observed at the shallow seismometers. Both the active-source test result and the recorded earthquake data demonstrated that the signal level is decreased with the increase of depth. Our result also shows that recorded motions at the ground and 1 m are strongly amplified at 20 Hz (T = 0.05 s), likely due to the resonance of the 3 m thick soil layer. This study demonstrates that analysis of ambient and active-source vibration may help find optimal installation depth of strong motion seismometers. We expect that further research considering various noise environments and geological conditions will be helpful in establishing a guideline for optimal installation of strong motion seismometers.

Analysis of Site Environment at Permanent GPS Stations Operated by National Geographic Information Institute (국토지리정보원 GPS 상시관측소 관측환경 분석)

  • Park, Kwan-Dong;Kim, Hye-In;Won, Ji-Hye
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.4
    • /
    • pp.337-345
    • /
    • 2007
  • National Geographic Information Institute has installed the first permanent Global Positioning System (GPS) station SUWN in 1995 and, as of today, the number of sites is 14. In this study, we visited all the 14 stations and determined if the site mount and antenna configuration conforms to the international site guidelines published by International GNSS Service and National Geodetic Survey. The environment around each station was also checked for the possibility of causing positioning errors. In addition, the GPS data quality was evaluated using the quality-checking program called TEQC. As a result of site visits, we found that low stations (TABK, CHJU, KWNJ, and WNJU) have unfavorable environment and TEQC results validated it. TEQC results also showed that the GPS receiver change during years 2005-2006 reduced the multipath errors and the number of cycle slips at every station.

Estimation of Subsurface Structure and Ground Response by Microtremor (상시미동에 의한 지하구조와 지반응답의 추정)

  • Hwang, Min-Woo;Kim, Sung-Kyun
    • Journal of the Korean earth science society
    • /
    • v.23 no.4
    • /
    • pp.380-392
    • /
    • 2002
  • The purpose of the present study is to evaluate the usage of microtremor in estimation of subsurface structure and ground response to strong ground motion. To accomplish the purpose, the current status of microtremor study are reviewed and microtremors recorded at several stations are analysed. First of all, the stability of microtremor is examined through the analysis of microtremors recorded for 80 seconds per hour during the time from 10 p.m. to 6 a.m. for eight hours at night time. It is found that the shape of microtremor spectra of low frequency below 10Hz is approximately invariable with time and the spectra contain informations about subsurface structure. The subsurface structures estimated from the predominant frequency determined from the recorded microtremors are compared with the known ones from geophysical surveys at several stations in Kyungju. The comparison of structures shows rough agreements at most stations. Horizontal to vertical spectral ratio(HVSR) technique for microtremor has been proposed as an indirect method to determine ground response to strong ground motion. The HVSR for microtremors recorded in Kyungju is calculated and compared with theoretical transfer function calculated from the known structures. The comparison shows rough coincidence of the peak frequency of spectra between them.

Thickness Analysis of the Alluvium and Yeonil Group in Pohang Area through the Microtremor HVSR Techniques (상시미동 HVSR 기법 적용을 통한 포항지역의 충적층 및 연일층군의 층후 분석)

  • Kim, Jeonghyun;Ki, Jungseok;No, Younghwa
    • The Journal of Engineering Geology
    • /
    • v.31 no.2
    • /
    • pp.211-222
    • /
    • 2021
  • The magnitude 5.4 earthquake occurred in 2017 near 7.5 km north of Buk-gu, Pohang. In order to find out the characteristics of microtremor in Buk-gu, Pohang, Gyeongsangbuk-do, where earthquake damage occurred significantly, a total of 39 points were acquired to analyze the horizontal to vertical spectral ratio (HVSR). Microtremor vary from region to region, so the resonant frequency of the region is obtained by examining the microtremor. For Thickness analysis, we analyze the structure and properties of shear wave velocity (Vs) up to the underlying rock to compare resonance frequencies to match the horizontal to vertical spectral ratio (HVSR) analysis technique against nearby boring data. Using F0 = Vs/4H with a resonance frequency of alluvium is 1.3 ± 0.07 Hz and a resonance frequency of Yeonil group is 0.69 ± 0.22 Hz, the alluvium thickness was found to be 26~30 m and the Yeonil group thickness was 170~250 m.

A Study on the Introduction of GPS Virtual Reference System in South Korea (GPS 가상기준점 도입에 관한 연구)

  • 최윤수;이용창;권재현;이재원
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.2
    • /
    • pp.105-116
    • /
    • 2004
  • According to the developing advanced techniques and removal of Selective Availability, much research has been conducted to improve the accuracy of GPS positioning in absolute and relative mode by estimating the nuisance parameters such as atmospheric effect, clock errors and multipath. Especially, the continuous effort of establishing the CORS in many countries and the effort of ICS making effective global networking make more application areas and the necessity of more precise location is being increased. Some of the countries like German, Japan and Swiss already utilized the Virtual Reference System for better location accuracy and services. In this study, the VRS system is investigated in terms of system principle, required H/W and S/W, management and operation, revision of related law, expected application and market etc. and find optimal solution in each aspect for economic and fast set up of the system in this country. The analysis of Korean CORS, communication infra and market estimation is performed for the efficient system establishment. Also. the suggestion on the advertisement and education of the system is also included. It is expected that this study contributes for the establishment of effective and precise nationwide location service so that many SOC areas including navigation, GIS, Telematics, LBS can provides better service for the users.