• Title/Summary/Keyword: 상시관측소

Search Result 119, Processing Time 0.028 seconds

Retrieval Biases Analysis on Estimation of GNSS Precipitable Water Vapor by Tropospheric Zenith Hydrostatic Models (GNSS 가강수량 추정시 건조 지연 모델에 의한 복원 정밀도 해석)

  • Nam, JinYong;Song, DongSeob
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.4
    • /
    • pp.233-242
    • /
    • 2019
  • ZHD (Zenith Hydrostatic Delay) model is important parameter in estimating of GNSS (Global Navigation Satellite System) PWV (Precipitable Water Vapor) along with weighted mean temperature. The ZWD (Zenith Wet Delay) is tend to accumulate the ZHD error, so that biases from ZHD will be affected on the precision of GNSS PWV. In this paper, we compared the accuracy of GNSS PWV with radiosonde PWV using three ZHD models, such as Saastamoinen, Hopfield, and Black. Also, we adopted the KWMT (Korean Weighted Mean Temperature) model and the mean temperature which was observed by radiosonde on the retrieval processing of GNSS PWV. To this end, GNSS observation data during one year were processed to produce PWVs from a total of 5 GNSS permanent stations in Korea, and the GNSS PWVs were compared with radiosonde PWVs for the evaluating of biases. The PWV biases using mean temperature estimated by the KWMT model are smaller than radiosonde mean temperature. Also, we could confirm the result that the Saastamoinen ZHD which is most used in the GNSS meteorology is not valid in South Korea, because it cannot be exclude the possibility of biases by latitude or height of GNSS station.

"우주물체 전자광학 감시체계 기술개발" 소개

  • Park, Jang-Hyeon;Choe, Yeong-Jun;Jo, Jung-Hyeon;Im, Hong-Seo;Mun, Hong-Gyu;Park, Jong-Uk;Choe, Jin;Kim, Jae-Hyeok;Jo, Gi-In
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.130.1-130.1
    • /
    • 2011
  • 인류의 우주공간에 대한 영향력이 확대됨에 따라, 우주공간에서의 인위적인 활동에 영향을 미칠 수 있는 모든 종류의 상황들에 대한 이해가 최근 전 세계적으로 매우 중요한 이슈로 부상하고 있다. 이를 Space Situational Awareness (SSA)라고 하는데, 특히 근지구공간에서의 인위적, 자연적 우주물체는, 우주발사체의 지속적인 증가와 이리듐-코스모스 위성의 상호 충돌 및 중국 폐기위성 파괴 등과 같은 사건으로 기하급수적으로 증가된 우주물체의 개체수로 인해 대한민국 국적의 모든 위성에도 실제적인 위협 요인으로 대두되고 있다. 이에 기초 기술연구회와 한국천문연구원은 이러한 위협을 국가적으로 해결해야할 과제(National Agenda Project) 중의 하나로 정의하고, 이를 해결하기 위해 우주물체 전자광학 감시체계 기술개발(OWL; Optical Wide-field patroL) 사업을 시작하였다. 이 사업의 목표는 자국위성에 대한 궤도력을 독자적으로 유지할 수 있는 시스템을 개발하는 것이며, 이를 위하여 2011년부터 6년 동안 총 5개소의 해외 관측소에 50cm급 광시야 망원경을 각각 설치하여 자국위성을 자동으로 상시관측하고, 관측된 자료를 이용한 궤도계산을 통하여 독자적으로 궤도력을 유지할 계획이다. 또한, 우주잔해물 감시는 하나의 국가에서 단독으로 할 수 없기 때문에 2m급 우주물체 감시망원경을 개발하여 국제공동으로 진행할 계획이다. 사업 첫해인 2011년 4월 시스템 요구사항 분석을 완료하였고 10월말 시스템 기본설계를 완료할 예정이다. 최종 완성될 소구경 광시야 망원경과 우주물체 감시망원경의 주요 임무는 우주물체 관측이지만, 향후 광시야를 이용한 다양한 탐사천문학에도 기여할 수 있을 것으로 기대한다. 한편, 자국위성에 대한 충돌 위험도 분석 및 회피기동에 관한 연구는 한국항공우주연구원이 이 사업의 협동연구로 참여하고 있다.

  • PDF

Missing Hydrological Data Estimation using Neural Network and Real Time Data Reconciliation (신경망을 이용한 결측 수문자료 추정 및 실시간 자료 보정)

  • Oh, Jae-Woo;Park, Jin-Hyeog;Kim, Young-Kuk
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.10
    • /
    • pp.1059-1065
    • /
    • 2008
  • Rainfall data is the most basic input data to analyze the hydrological phenomena and can be missing due to various reasons. In this research, a neural network based model to estimate missing rainfall data as approximate values was developed for 12 rainfall stations in the Soyang river basin to improve existing methods. This approach using neural network has shown to be useful in many applications to deal with complicated natural phenomena and displayed better results compared to the popular offline estimating methods, such as RDS(Reciprocal Distance Squared) method and AMM(Arithmetic Mean Method). Additionally, we proposed automated data reconciliation systems composed of a neural network learning processer to be capable of real-time reconciliation to transmit reliable hydrological data online.

Study on the Change of Rating Curve by Monitoring of Downstream Weir with Gates Operation (하류 보 운영 모니터링을 통한 수위-유량관계곡선 변화 연구)

  • Kim, Soo Jeong;Park, Jun Su;Lee, Jae Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.411-411
    • /
    • 2022
  • 보는 수로나 하천의 수위를 조절하고 취수 등의 편의를 제공하기 위해 건설되는 하천 구조물이다. 일반적인 보(고정보)는 상시 담수 되어 농업용수, 생활용수, 공업용수 등의 취수원으로 활용되지만, 최근에 설치되는 보(가동보)들은 수문을 설치하여 필요에 따라 수위를 조절할 수 있게 되어 있다. 이와 같은 보의 운영은 보 상류의 유속, 수심, 흐름 특성, 하천 형상 등의 변화를 발생시킨다. 특히 하류 보는 운영현황에 따라 하천 흐름에 직접적인 영향을 주기 때문에 하천 흐름 특성에 핵심적인 요소로 볼 수 있다. 따라서 이에 대한 모니터링이 필요하며 이에 따른 수위-유량관계를 규명할 필요가 있다. 본 연구에서는 함평천 유역에 위치한 함평군(영수교)관측소를 대상으로 하류 약 1.3km에 위치한 개량형 공압식 가동보의 2021년 기립각도 변화에 대한 보 모니터링을 실시하여 수위-유량관계 변화를 분석하였다. 2021년에는 가동보의 기립각도 변화 및 취수조건에 따라 총 37회의 수위관측 및 유량측정을 하였으며 총 29회의 가동보의 기립각도를 계측하였다. 2021년 전반기에는 부분개방1, 부분개방2, 부분개방3, 완전개방, 취수조건으로 기간 분리되었고 후반기에는 완전개방, 부분개방3, 부분개방4, 부분개방5 조건으로 가동보의 기립각도에 따라 총 6개의 기간분리가 발생하였다. 결과적으로 본 연구에서는 하류 가동보 운영현황에 대한 보 모니터링과 흐름 특성이 변화하는 기간의 유량측정성과 확보를 통해 신뢰도 높은 수위-유량관계곡선식을 개발하였고 이를 통해 생산된 유량자료는 정확도가 매우 높은 것으로 분석되었다.

  • PDF

Generation of Grid Maps of GPS Signal Delays in the Troposphere and Analysis of Relative Point Positioning Accuracy Enhancement (GPS 신호의 대류권 지연정보 격자지도 생성과 상대측위 정확도 향상 평가)

  • Kim, Dusik;Won, Jihye;Son, Eun-Seong;Park, Kwan-Dong
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.825-832
    • /
    • 2012
  • GPS signal delay that caused by dry gases and water vapor in troposphere is a main error source of GPS point positioning and it must be eliminated for precise point positioning. In this paper, we implemented to generate tropospheric delay grid map over the Korean Peninsula based on post-processing method by using the GPS permanent station network in order to determine the availability of tropospheric delay generation algorithm. GIPSY 5.0 was used for GPS data process and nationwide AWS observation network was used to calculate the amount of dry delay and wet delay separately. As the result of grid map's accuracy analysis, the RMSE between grid map data and GPS site data was 0.7mm in ZHD, 7.6mm in ZWD and 8.5mm in ZTD. After grid map accuracy analysis, we applied the calculated tropospheric delay grid map to single frequency relative positioning algorithm and analyzed the positioning accuracy enhancement. As the result, positioning accuracy was improved up to 36% in case of relative positioning of Suwon(SUWN) and Mokpo(MKPO), that the baseline distance is about 297km.

The Development for KASS Reference Station Site (KASS 기준국 사이트 구축)

  • Cho, Sunglyong;Jang, Hyunjin;Jeong, Hwanho;Lee, Byungseok;Nam, Giwook
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.273-279
    • /
    • 2020
  • In the Korea's SBAS(KASS), reference site is an important infrastructure facility for the collecting and monitoring GPS/GEO signals. The SBAS reference station has an clear requirements than other regular monitoring stations. It requires constant maintenance during the system operation. The development for KRS site should be prepared for site survey, site construction, antenna geodetic survey, equipment installation and operation. Site survey is initially performed as an important step to predict site availability and system performance. The operation center must provide the reference site, equipment room, and appurtenant to satisfy the site requirements. The position of antennas is very important information, and accuracy must be secured through the geodetic survey. Measurement collected at the from precise antenna are provided to the KASS processing station. The position of antenna should be maintained through continuous position checks and updates during the operation. When the development of the KRS site is completed, it performs tasks for installing and operating the KRS equipment. In this paper, we presented the procedures and some results for the development of the 7 KRS sites.

Analysis of groundwater level change using groundwater monitoring network in Miryang area. (지하수관측망을 이용한 밀양지역의 지하수 변화 분석)

  • Baek, Mi Kyung;Sim, Gyu Sung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.221-221
    • /
    • 2019
  • 기후변화로 인한 가뭄대비가 상시체제가 된 요즈음, 농업용수의 안정적인 공급을 위하여 가뭄 등의 비상시 지표수는 물론이고 지하수의 공급 가능량에 대해서도 국가적 관리가 필요한 실정이다. 지하수관리를 위해 국가 최상위 계획인'지하수관리기본계획(2012~2021)'이 수립되었고, 지하수의 장기적인 수량, 수질 관리를 위해 국가지하수관측망, 지역지하수관측망(보조지하수관측망), 수질측정망, 해수침투관측망 등 광역과 지역단위로 크게 나누어 지하수관측이 이루어지고 있다. 국가지하수관측망은 지하수법에 의거하여 전국의 주요지점(2016년 말 기준 412개소)에 관측소를 설치하여 수위 및 수질의 변동실태를 광역적으로 분석함이 목적이며, 보조지하수관측망은 국가지하수관측망과 연계하고 보완하기 위한 기능으로서, 지역별 주요 관측지점의 수위, 수질자료를 획득하며, 2018년 9월 현재 3,429개소가 설치되어있다. 본 연구에서는 지역지하수 관측망 중 경남밀양지역에 설치된 관측정 31개소에 대해 수위와 수질을 장기 분석하였다. 밀양지역의 보조지하수관측망 설치는 지하수관리계획의 하부계획인'경상남도 지하수관리계획(2015~2025)'에 의거 2012년에 6개소의 관측공이 설치를 시작으로, 2013년 7개소, 2014년 10개소, 2015년 8개소를 설치하여 총 31개소의 설치를 완료하였고, 2016년부터 2019년 현재까지 전체 관측정 31개소에 대하여 관측 운영 중이다. 본 연구에서는 2013년 1월~2019년 1월까지 지역의 누적강수량과 지하수위 및 수질변화를 관측하였다. 전 관측정에 대해 수위(GL.m), 수질(온도, EC)은 1시간 주기로 관측하였으며, 연 2회 생활용수 기준(19항목)의 수질검사를 실시하고, 지하수성분의 지질학적 기원분석을 위한 양음이온 분석을 연 1회 실시하였다. 관측정의 양수능력 변화관측을 위해 대수성 시험을 연 1회 실시하였고, 관측정의 특성상 장기간 미사용 관정이므로 최적의 상태유지를 위해 연1회 공내세척을 실시하였다. 또한, 관측정의 지형별 차이를 분석하기 위해 관측정의 설치위치를 산악, 강변, 기타 지역으로 구분하고, 각각의 대표관정에 대해 지형에 의한 서로 다른 영향을 분석하였고, 관측정의 심도별 변화를 알기위해 동일지역에 충적, 안반 관측정을 따로 설치하고 관측하여 지표수와 지하수의 심도별 영향의 차이를 분석하였다. 동일지역의 관측결과 평균 5m이하의 수위변화를 보이나, 5m 이상의 수위변동을 보이는 관측망은 15년 14개소 17년 19개소로 증가추세를 보이며, 이는 주로 밀집된 시설하우스 단지의 수막재배를 위한 겨울철 지하수 사용량 증가가 원인인 것으로 판단된다. 밀양지역은 강변지역에 밀집된 시설하우스단지의 동절기 수막재배를 위한 지하수 과다사용으로 수위급감 및 수량부족현상이 반복되고 있어, 예방과 대책강구를 위해 지표수의 함양과 지하수사용량의 상관관계 분석과 자료축적 및 추가연구를 위한 장기관측이 요구된다.

  • PDF

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

Comparative Analysis of GNSS Precipitable Water Vapor and Meteorological Factors (GNSS 가강수량과 기상인자의 상호 연관성 분석)

  • Jae Sup, Kim;Tae-Suk, Bae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.4
    • /
    • pp.317-324
    • /
    • 2015
  • GNSS was firstly proposed for application in weather forecasting in the mid-1980s. It has continued to demonstrate the practical uses in GNSS meteorology, and other relevant researches are currently being conducted. Precipitable Water Vapor (PWV), calculated based on the GNSS signal delays due to the troposphere of the Earth, represents the amount of the water vapor in the atmosphere, and it is therefore widely used in the analysis of various weather phenomena such as monitoring of weather conditions and climate change detection. In this study we calculated the PWV through the meteorological information from an Automatic Weather Station (AWS) as well as GNSS data processing of a Continuously Operating Reference Station (CORS) in order to analyze the heavy snowfall of the Ulsan area in early 2014. Song’s model was adopted for the weighted mean temperature model (Tm), which is the most important parameter in the calculation of PWV. The study period is a total of 56 days (February 2013 and 2014). The average PWV of February 2014 was determined to be 11.29 mm, which is 11.34% lower than that of the heavy snowfall period. The average PWV of February 2013 was determined to be 10.34 mm, which is 8.41% lower than that of not the heavy snowfall period. In addition, certain meteorological factors obtained from AWS were compared as well, resulting in a very low correlation of 0.29 with the saturated vapor pressure calculated using the empirical formula of Magnus. The behavioral pattern of PWV has a tendency to change depending on the precipitation type, specifically, snow or rain. It was identified that the PWV showed a sudden increase and a subsequent rapid drop about 6.5 hours before precipitation. It can be concluded that the pattern analysis of GNSS PWV is an effective method to analyze the precursor phenomenon of precipitation.