• Title/Summary/Keyword: 상세화학반응식

Search Result 13, Processing Time 0.017 seconds

Dynamic Optimization of a Reactive Distillation Column Producing Methyl Acetate (메틸 아세테이트 생산을 위한 반응증류 공정의 동적 최적화)

  • Kim, Jiyong;Kim, Junghwan;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.46 no.4
    • /
    • pp.739-746
    • /
    • 2008
  • The aim of this study is finding the optimal design parameters and the optimal operation variables of a reactive distillation column. Different from steady state optimization, dynamic optimization makes it possible considering operation ability as well as design problems at process design step. For performing dynamic optimization, dynamic simulation should be done first. If dynamic simulation is already finished, dynamic optimization can be performed with less effort than that of dynamic simulation.Reactive distillation systems involving reaction and separation in a single unit have the potential to reduce capital and operating costs, particularly when reaction have conversion constraint or when azeotropes exist making conventional separation difficult and expensive. This study here present work on the continuous distillation process, the homogeneous catalyzed esterification of methanol and acetic acid, the synthesis of methyl acetate. Based on an equilibrium stage model of a reactive distillation column a dynamic optimization problem was formulated and solved. And the results were verified by performing dynamic simulation and showing the variation of conversion and purity as the variation of the operation variables. As the results of dynamic optimization, this study found optimal feed ratio, reflux ratio and reboiler duty of this system. And as this study applied it to dynamic simulations the dynamic characteristics of a reactive distillation column are showed under optimal operating condition.

A Phase I/II Trial of $DCVac/IR^{(R)}$ Dendritic Cell Immunotherapy Combined with Irradiation in Cases of Refractory Colorectal Cancer with Multiple Liver Metastases (기존의 치료에 반응하지 않는 다발성 간전이 대장암 환자에서 방사선조사와 병합한 수지상세포 면역치료의 1, 2상 임상시험)

  • Choi, Young-Min;Lee, Hyung-Sik;Kwon, Hyuk-Chan;Han, Sang-Young;Choi, Jong-Cheol;Chung, Ju-Seop;Kim, Chang-Won;Kim, Dong-Won;Kang, Chi-Duk
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.104-112
    • /
    • 2008
  • Purpose: To assess the toxicity and tumor response induced by $DCVac/IR^{(R)}$ dendritic cell(DC) immunotherapy combined with irradiation for refractory colorectal cancer patients with multiple liver metastases. Materials and Methods: Between May 2004 and November 2006, applicants from a pool of refractory colorectal cancer patients with multiple liver metastases were enrolled. The patients were registered after having signed the informed consent form, which had been approved by the Institutional Review Board from the Dong-A University and Busan National University Hospital. DCs were obtained from peripheral blood of each patient, and then cultured in vitro. A total of $6{\times}10^6$ DCs were packed into a vial($DCVac/IR^{(R)}$, 0.5 ml) at the convenience of each patient's schedule. On the day before and on the day of each vaccination, each patient received a 4 Gy radiation dose to the target tumor. On the day of vaccination, the indicated dose of autologous DCs was injected into the irradiated tumor using ultrasound-guided needle injection procedures. A total of four vaccinations were scheduled at three 2-week intervals and one 4 week interval at the Dong-A University and Busan National University Hospital. If the tumor status was deemed to be stable or responding to therapy, an additional vaccination dose or two was approved at 4 week intervals beyond the fourth immunization. A tolerance test for DCs was conducted by injecting a range of doses($3{\times}10^6\;to\;12{\times}10^6$ DCs) after the 3rd injection. Moreover, the maximal tolerable dose was applied to additional patients. Treatment safety was evaluated in all patients who had at least one injection. Treatment feasibility was evaluated by the 10th week by assessing the response of patients having at least 4 injections. For systemic toxicities, the evaluation was performed using the National Cancer Institute Common Toxicity Criteria, whereas adverse effects were recorded using common WHO toxicity criteria. Results: Of the 24 registered patients, 22 received the DCs injections. Moreover, of the 14 patients that applied for the tolerance test, only 11 patients completed it because 3 patients withdrew their testing agreement. A grade 3 or more side effect, which was possibly related to the DC injection, did not occur in additional patients. The $12{\times}10^6$ DC injection was identified as the maximum tolerable dose, and was then injected in an additional 8 patients. Patients tolerated the injection fairly well, with no fatal side effects. In order to assess the feasibility of DC immunotherapy, the response was evaluated in other hepatic lesions outside of the targeted hepatic lesion. The response evaluation was performed in 15 of the 17 patients who received at least 4 injections. Stable and progressive disease was found in 4 and 11 patients, respectively. Conclusion: The DC-based immunotherapy and radiotherapy is theoretically synergistic for the local control and systemic control. The $DCVac/IR^{(R)}$ immunotherapy combined with irradiation was tolerable and safe in the evaluated cases of refractory colorectal cancer with multiple liver metastases. Future work should include well designed a phase II clinical trials.

Study of the ENC reduction for mobile platform (모바일 플랫폼을 위한 전자해도 소형화 연구)

  • 심우성;박재민;서상현
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.181-186
    • /
    • 2003
  • The satellite navigation system is widely used for identifying a user's position regardless of weather or geographic conditions and also make effect on new technology of marine LBS(Location Based Service), which has the technology of geographic information such as the ENC. Generally, there are conceivable systems of marine LBS such as ECDIS, or ECS that use the ENC itself with powerful processor in installed type on ships bridge. Since the ENC is relatively heavy structure with dummy format for data transfer between different systems, we should reduce the ENC to small and compact size in order to use it in mobile platform. In this paper, we assumed that the mobile system like PDA, or Webpad can be used for small capability of mobile platform. However, the ENC should be updated periodically by update profile data produced by HO. If we would reduce the ENC without a consideration of update, we could not get newly updated data furthermore. As summary, we studied considerations for ENC reduction with update capability. It will make the ENC be useful in many mobile platforms for various applications.

  • PDF