• Title/Summary/Keyword: 상사모형

Search Result 222, Processing Time 0.028 seconds

Verification of Calculated Hydrodynamic Forces Acting on Submerged Floating Railway In Waves (파랑 중 해중철도에 작용하는 유체력 계산 및 검증)

  • Seo, Sung-Il;Mun, Hyung-Seok;Lee, Jin-Ho;Kim, Jin-Ha
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.6
    • /
    • pp.397-401
    • /
    • 2014
  • In order to rationally design a new conceptual submerged floating railway, prediction of wave forces applied to the structure is very important. In this paper, equations to calculate such forces based on hydrodynamic theories were proposed and model tests were carried out. Inertia forces and drag forces, calculated using Morison's equation and the linear small amplitude wave theory, were in good agreement with the results from model tests conducted in a wave making tank. Drag forces were negligible compared with inertia forces. Also, wave forces showed linear variation with the changing wave heights. It was revealed that the linear wave theory and Morison's equation can give a simple and useful solution for the prediction of wave forces in the initial design stage of a submerged floating railway.

Evaluation of Dissipation Behavior of Excess Pore Pressure in Liquefied Sand Deposit Using Centrifuge Tests (원심모형실험을 이용한 액상화 모래지반의 과잉간극수압 소산거동 분석)

  • Kim Sung-Ryul;Ko Hon-Yim;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • Soil liquefaction occurs by complex dynamic interaction between soil particles and pore fluid. Therefore, experimental researches have been widely performed to analyze liquefaction phenomena. In this research, centrifuge tests were performed to analyze the liquefaction behavior of horizontal sand ground. Centrifugal acceleration was 40g and the thickness of model ground was 25cm, which simulates 10m thickness in prototype scale. Viscous fluid was used as pore fluid to remove the time scaling difference between dissipation and dynamic shaking. Test results showed that the dissipation of excess pore pressure is the combined behavior of solidification and consolidation. In addition, the solidification rate, the ground acceleration amplitude, and the dynamic permeability during solidification were influenced by the confining pressure.

Effect of design factors on the performance of heat exchanger with a slit fin (슬릿휜형 열교환기의 성능에 대한 설계인자의 영향)

  • Yun, J.Y.;Lee, K.S.;Kim, H.Y.;Kang, H.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.210-220
    • /
    • 1997
  • This study is to systematically analyze the effect of various kinds of design parameters on heat transfer and pressure drop characteristics of heat exchanger with a slit fin. TAGUCHI method, known to us as a very reasonable tool in the parametric study, is employed in the present work. Experimental factors have been limited to seven cases, considering the production of sample and the cost. The 18 kinds of large scale models are made by compounding level on each factor and the heat transfer and flow characteristics on each model has been analyzed. The present results allow us to be able to quantitatively estimate the various parameters affecting the heat exchanger performance, and main factors for an optimum design of a heat exchanger have been selected. The optimum design value on each parameter was presented and the reproducibility on the results was guaranteed.

  • PDF

A large scale model test to investigate the pressure drop and heat transer characteristics in the air side of two-row heat exchanger (2열 휜 튜브 열교환기의 공기측 압력강하 및 열전달 특성을 고찰하기 위한 확대 모형실험)

  • Gang, Hui-Chan;Kim, Mu-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.113-124
    • /
    • 1997
  • This work is performed to investigate the pressure drop and heat transfer characteristics in the air side of finned-tube heat exchanger for air conditioner. Experimental apparatus and method are described to simulate the heat exchanger performance by using the three times enlarged model. The pressure drop and heat transfer coefficient were measured and compared for the heat exchangers with a plane fin and a commercial strip fin. The measured data for the strip fin agree well with those of prototype within a few percentages. For the plane fin, the measured data had similar trend to Gray & Webb's correlation at high air velocity, however a new correlation is needed to give more accurate prediction at low air velocity. It is found that most heat was transferred around the front row of the two-row heat exchanger, and the ratio of thermal load at the front tube row was increased for decreasing air velocity.

An Experimental Study on the Determination of Backlayering Distance in Tunnel Fires (터널 화재시 역기류의 위치 결정에 관한 실험적 연구)

  • 이성룡;유홍선
    • Tunnel and Underground Space
    • /
    • v.14 no.4
    • /
    • pp.269-274
    • /
    • 2004
  • In this study reduced-scale experiments were conducted to determine the backlayering distance in tunnel fires. The 1/20 scale experiments were carried out under the Froude scaling using ethanol square pool fire ranging from 8 to 1km in each side with total heat release rate from 2.47 to 12.30 ㎾. It has been found that ventilation velocity increases with aspect ratio(tunnel height/tunnel width). At L$\_$B/$\^$*/ <5 the ventilation velocity increases proportional to the backlayering distance from 0.25 power of the heat release rate. However at L$\_$B/$\^$*/ $\geq$5 the ventilation velocity varies as the 0.3 power of the heat release rate.

A Construction of Aerodynamic Force Measurement System for Wind Tunnel Test of Yacht Sail and Aerodynamic Forces Measurement of Model Sail (요트세일의 풍동시험을 위한 공력 계측시스템 구축과 모형세일의 공력 계측)

  • Kim, Choul-Hee;Choi, Jung-Kyu;Kim, Hyoung-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.5
    • /
    • pp.445-450
    • /
    • 2011
  • In order to estimate a yacht sail performance, measuring system of aerodynamic forces acting on the yacht sail is constructed and experiments of flexible model sail are carried out at the medium-size subsonic wind tunnel of Chungnam National University. Experimental results for a flexible sail are compared with experimental and numerical results of fixed shape sail. In case of a fixed shape sail, lift and drag coefficients are rarely changed at all velocity conditions. However, those of the flexible sail are decreased as the incoming velocity is increased. These are understandably resulted from shape variations due to the flexible material. Therefore aero-elastic similarity should be more carefully considered in the model test rather than other similarities.

Plane Vertical Bvoyant Jets in Crossflow (가로흐름 수역에서 연직상향 평면부력\ulcorner)

  • Yun, Tae-Hun;Cha, Yeong-Gi;Kim, Chang-Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1986.07a
    • /
    • pp.131-145
    • /
    • 1986
  • 흐름수역에서 연직상향으로 방류되는 평면부력\ulcorner의 거동이 연속방정식, 운동량방정식 및 추적물수송식의 기본방정식에 의하여 수치적으로 해석된다. 난류확산에는 Prandtld의 혼합거리이론을 도입한 난류수송모형이 이용된다. 수치해 과정은 기본방정식을 유함수(stream function)식, 와도수송(vorticity transport)식으로 변환한 후, \ulcorner방류속도와, 방류구폭 등으로 표현되는 변수와 흐름을 지배하는 무차원 매개변수를 도입하여 무차원 형태로 표현하는 부분과 successive under-relaxation과 Gauss-Seidel반복법으로 수행하는 부분으로 이루어진다. 적절한 relaxation 계수를 선정하므로써 안정되고 수렴성이 좋은 계산이 수행된다. \ulcorner방류 속도와 가로흐름 속도의 비가 속도비(Velocity ratio)로 정의되며 속도비가 8 - 15의 범위에서 부력\ulcorner으로 인한 주변흐름수역의 속도변화 온도상승범위, 흐름상태(유선) 및 와도가 조사되었으며 \ulcorner의 경로에 대하여 속도비와 방류밀도후르드수의 영향이 또한 조사되었다. \ulcorner중심선의 속도와 온도변화, 국부밀도후르드수의 변화가 구해지며 퍼짐율(dispersion ratio), 확산비(spreading rate)가 방류밀도후르드수, 국부밀도후르드수 및 방류구로부터의 경로의 항으로 해석되었다. 또한 속도와 온도 분포에 상사(similarity)가 존재함이 밝혀졌으며 본 연구와 같은 조건의 범위에서는 Gaussian분포를 이용한 적분형해석(intergal type analysis)이 가능한 것으로 사료된다.

  • PDF

A Study on the Acoustic Absorption Character of a Helmholtz Resonator in Model Chamber (모형연소실에 장착한 헬름홀츠 공명기의 흡음특성에 관한 연구)

  • Park, Ju-Hyun;Sohn, Chae-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.399-402
    • /
    • 2009
  • Acoustic design parameters of a Helmholtz resonator are studied experimentally and numerically for acoustic stability in a model acoustic tube. According to standard acoustic-test procedures, acoustic-pressure signals are measured. Quantitative acoustic properties of sound absorption coefficient are evaluated and thereby, the acoustic damping capacity of the resonator is characterized. Helmholtz resonator on spring-damper system use were understanding for acoustic damping. The length of orifice and the volume of cavity of resonator are selected as design parameters for tuning of the resonator. Acoustic- damping capacity of the resonator increases with its cavity volume. And orifice length as increases with acoustic damping capacity was decreased.

  • PDF

Water Tightness around Under-ground Oil Storage Cavern (지하유류비축공동(地下油類備蓄空洞)의 수밀성(水密性)에 관한 연구(硏究))

  • Chung, Hyung Sik;Sun, Yong;Kim, Oon Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.33-38
    • /
    • 1982
  • A successful operation of underground oil storage cavern depends on water-tightness around cavern by groundwater. If water-tightness is not secured, gas bubbles would leak out and oil would migrate to an adjacent empty cavern. In this research an electrical analogy method was employed to study the influence of shape of cavern on gas leakage and the required natural groundwater level, relative oil level in two neighboring caverns and cavern spacing to prevent oil migration. The results show that gas leakage is prevented from a cavern with a ceiling of large curvature. The required values of factors to curtail the migration of oil are given on a graph.

  • PDF

Heat transfer characteristics of fin and tube heat exchangers with various interrupted surface for air conditioning application (다양한 형태의 단속표면을 갖는 공조기용 핀-관 열교환기의 열전달 특성)

  • Yun, Jeom-Yeol;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.3938-3948
    • /
    • 1996
  • This study is related with the experimental investigation on the heat transfer and pressure drop characteristics of the fin-and-tube heat exchangers with three different interrupted fins and a plane fin for air-conditioning application. Experiments were conducted accordingly following the appropriate development process. Geometry similitude experiment was introduced to predict the performance of fins, and prototype experiment was also performed to confirm the validity of geometry similitude experimental results. However, these experimental results were limited to the sensible heat transfer characteristics of the heat exchangers. Hence, additional experiment was performed using refrigerant to investigate the latent heat transfer characteristics. This paper presents an appropriate process for the development of a new type heat exchanger. Sensible and latent heat transfer characteristics for each fin configuration is also provided along with the optimal fin configuration.