• Title/Summary/Keyword: 상변화 냉각

Search Result 198, Processing Time 0.029 seconds

A Study on the Cooling Characteristics of TMA by an Additive (첨가제에 의한 TMA의 냉각특성에 대한 연구)

  • Chung Nak-Kyu;Kim Jin-Heung;Kim Chang-Oh;Kang Seung-Hyun
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.117-122
    • /
    • 2005
  • This study is performed to investigate the cooling characteristics of TMA $25\;wt\%$ clathrate compound with an additive; the phase change temperature, the degree of supercooling, specific heat and the rate of volume change. The used additive is ethanol and the heat source temperature is $-7^{\circ}C$. Experimental results are as follows: 1) The phase change temperature is increased by $0.32\~0.96^{\circ}C$ during the cooling process of TMA $25\;wt\%$ clathrate compound with ethanol. 2) The degree of supercooling is repressed by $0.9^{\circ}C$ in case of TMA $25\;wt\%$ clathrate compound with $0.5\;wt\%$ ethanol. 3) The specific heat is increased by $0.19\;kJ/kg^{\circ}C$ in case of TMA $25\;wt\%$ clathrate compound with $0.l\;wt\%$ ethanol. 4) The rate of volume change is decreased by $1.15\~l.5\%$ in case of TMA $25\;wt\%$ clathrate compound with ethanol.

투과 전자 현미경으로 관찰한 $Hg_{0.7}Cd_{0.3}Te$박막의 Hg 분위기 열처리 효과

  • Kim, Gwang-Cheon;Choe, Won-Cheol;Jeong, Gyu-Ho;Kim, Hyeon-Jae;Kim, Jin-Sang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.451-451
    • /
    • 2011
  • 적외선 소자의 재료로 쓰이는 액상 에피 성장법(Liquid phase epitaxy: LPE)으로 성장된 HgCdTe (MCT)박막의 Hg 분위기 열처리에 따른 구조적 변화를 고 분해능 투과 전자 현미경으로 관찰하였다. 일반적으로 LPE방법으로 성장된 MCT박막은 성장 방법의 특성상 Te 과다 영역의 성장용액이 사용되므로 상온 냉각 과정에서 박막 내 국부적인 Te 석출물을 형성 시킬 가능성이 높다. 또한, 성장 과정시 높은 Hg 증기압으로 인해 Hg-vacancy가 존재하므로 품질을 저하시키는 요인이 된다. 따라서, 본 실험에서는 Hg-vacancy와 국부적인 Te 석출물의 제거를 위해 Hg 분위기 열처리 공정을 실시하여 박막의 결정성 변화 및 국부적인 조성 변화를 관찰하였다. 실험결과, 열처리에 따른 Hg의 박막 내 공급으로 인한 이차상의 형성 등이 관찰 되었으며 부피 팽창으로 인해 격자의 변형이 관찰 되었다. 이는 투과 전자 현미경의 고 분해능 이미지 와 Gaussian mask filtering 기법으로 보여진 격자 줄무늬상 (lattice fringe)으로 확인 하였다. 또한, 열처리에 따른 국부적인 조성 편기의 해소는 high angle annular dark field scanning TEM(HAADF-STEM)을 이용하여 관찰 하였다.

  • PDF

Experimental Study on the Freezing Conditions in a Ice-making Tube Using Flowing Subcooled Water (유동과 냉각수 이용 제빙관의 동결조건에 5관한 실험적 연구)

  • 박영하;현명택;이동원
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.178-183
    • /
    • 2000
  • 본 연구에서는 유동과 냉각수를 이용하는 아이슬러리 제조관정을 관찰하고, 이 시스템의 가장 큰 문제점인 관내동결 특성을 파악하였다. 시험수로는 수도수(city water)를 이용하였다. 시스템을 순환하는 시험수가 제빙관내에서 $0^{\circ}C$ 이하의 과냉각 조건이 형성되어 제빙관을 빠져 나오면서 축냉조에 설치된 충격판상에서 과냉각 해소가 일어났다. 이때 유동과냉각수는 내부에너지를 방출하면서 그 일부가 얼음 입자로 상변화되었고, 나머지는 실험장치를 계속순환하였다. 제빙관에서 시험수와 브라인의 열교환 방식을 대향류와 평행류 두 조건에서 시험수의 과냉각도는 Reynolds 수가 증가함에 따라 감소하는 경향을 보였고, 이들 결과 값으로부터 각각의 관계식을 유도하였다. 또한 브라인의 냉각속도가 0.29~0.53[$^{\circ}C$/min] 범위에서 시험수의 과냉각도는 브라인 냉각속도에 종속되지 않았다.

  • PDF

다상 나노 복합 구조를 가지는 Cu계 벌크 비정질 합금에서 불균일성 제어에 의한 특성 조절

  • Kim, Jin-U;Park, Eun-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.502-502
    • /
    • 2011
  • 기존 연구에서는 단일 타겟으로부터 증착된 코팅층 내에 다상으로 이루어진 나노 복합구조를 형성하기 위하여, 나노 합금분말을 방전플라즈마 소결법 등으로 급속 소결하여 타겟을 제조하는 방법이 고려되어 왔다. 반면, 비정질 재료가 우수한 비정질 형성능을 가지는 경우 주조 방법에 의해서도 타겟 제조가 가능하며, 특히 최근 들어 금속 비정질 합금에서 합금의 주요 구성 원소들이 양의 혼합열을 가지는 경우, 액상 또는 과냉각 액상에서 상분리 현상이 발생한다는 것이 밝혀졌다. 이러한 사실에 기초하면, 우수한 비정질 형성능을 가지는 합금 시스템에 합금 구성 원소와 양의 혼합열 관계를 갖는 원소를 첨가함으로써, 비정질 기지 내에 화학적 불균일성을 유도하여 다상으로 이루어진 복합 구조를 형성시키는 것이 가능하다. 본 연구에서는 이러한 합금 설계법을 이용하여, 비정질 기지 내에 존재할 수 있는 불균일성 정도를 합금 조성과 주조 조건의 변화를 통하여 나노 크기에서 원자 크기까지 조절하고, 이에 따른 재료 특성과의 상관관계를 밝히고자 하였다. 이를 위하여 우수한 비정질 형성능을 가지는 Cu-(Zr, Hf)-Al 벌크 비정질 합금계에서 (Zr, Hf)과 (Y, Gd)간의 양의 혼합열 관계에 주목하여 Cu-(Zr, Hf)-(Y, Gd)-Al 벌크 비정질 형성 합금계를 설계하였으며, 이 합금계 내에서 조성과 냉각속도의 조절에 따라 나타나는 불균일성의 정도와 특성변화의 영향을 체계적으로 고찰하였다. 결과로서, Cu-(Zr, Hf)-Al 합금계에서 (Zr, Hf)을 (Y, Gd)으로 15 at.% 이상 치환한 경우, Cu-(Zr, Hf)-rich 와 Cu-(Y, Gd)-rich 비정질상으로 이상분리가 일어났으며, 이렇게 생성된 비정질-비정질 복합재는 응력 하에서 소성 변형을 거의 보이지 않았다. 반면, 5 at.% 이하로 (Zr, Hf)을 (Y, Gd)으로 치환한 경우에는 비정질 기지에 SAXS 혹은 WAXS로 확인 가능한 원자 크기의 불균일성이 나타났으며, 이 경우 비정질 합금의 점성 유동의 변화를 통해 합금의 연신 특성이 향상되었다. 특히, 본 연구에서는 비정질 기지내 불균일 제어를 통한 기계적 특성 향상을 위해서 조성 제어뿐 아니라 동역학적인 요소를 고려한 냉각속도 조절을 통한 원자단위 불균일성의 최적화가 필요함을 규명하였다. 이러한 연구 결과는 분말화 및 소결 과정을 배제하고 제조된 단일 타겟을 통해 코팅층에 다수의 합금원소를 혼합하고 나노/원자 스케일의 복합구조 형성 및 고집적화가 가능한, 타겟 모물질 설계의 새로운 방향을 제시함으로써 다기능성 복합소재 코팅층의 연구에 크게 기여할 것으로 사료된다.

  • PDF

Development of Small Flat Plate Type Cooling Device (소형의 평판형 냉각장치 개발)

  • Moon, Seok-Hwan;Hwang, Gunn;Kang, Seung-Youl;Cho, Kyoung-Ik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.614-619
    • /
    • 2010
  • Recently, a problem related to the thermal management in portable electronic and telecommunication devices is becoming issued. That is due to the trend of a slimness of the devices, so it is not easy to find the optimal thermal management solution for the devices. From now on, a pressed circular type cooling device has been mainly used, however the cooling device with thin thickness is becoming needed by the inner space constraint of the applications. In the present study, the silicon flat plate type cooling device with the separated vapor and liquid flow path was designed and fabricated. The normal isothermal characteristics created by vapor-liquid phase change was confirmed through the experimental study. The cooling device with 70 mm of total length showed 6.8 W of the heat transfer rate within the range of $4{\sim}5^{\circ}C/W$ of thermal resistance. In the future, it will be possible to develop the commercialized cooling device by revising the fabrication process and enhancing the thermal performance of the silicon and glass cooling device.

Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus (냉이온수기 냉각시스템에 관한 열유동 해석)

  • Jeon, Seong-Oh;Lee, Sang-Jun;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Study on cooling performance and isothermal maintenance of cylindrical type lithium-ion battery cell using phase change material (상변화물질을 활용한 원통형 리튬이온 배터리 셀의 냉각성능 및 등온유지성에 관한 연구)

  • Jae Hyung Yoon;Su Woong Hyun;Hee Jun Jeong;Dong Ho Shin
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.34-45
    • /
    • 2023
  • When lithium-ion batteries operate out of the proper temperature range, their performance can be significantly degraded and safety issues such as thermal runaway can occur. Therefore, battery thermal management systems are widely researched to maintain the temperature of Li-ion battery cells within the proper temperature range during the charging and discharging process. This study investigates the cooling performance and isothermal maintenance of cooling materials by measuring the surface temperature of a battery cell with or without cooling materials, such as silicone oil, thermal adhesive, and phase change materials during discharge process of battery by the experimental and numerical analysis. As a result of the experiment, the battery pack filled with phase change material showed a temperature reduction of 47.4 ℃ compared to the case of natural convection. It proves the advanced utility of the cooling unit using phase change material that is suitable for use in battery thermal management systems.

Effect of cooling rate on precipitation hardening of a Pd-Cu-Ga-Zn metal-ceramic alloy during porcelain firing simulation (금속-세라믹용 Pd-Cu-Ga-Zn계 합금의 모의 소성 시 냉각 속도가 석출 경화에 미치는 영향)

  • Kim, Min-Jung;Shin, Hye-Jeong;Kwon, Yong-Hoon;Kim, Hyung-Il;Seol, Hyo-Joung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.207-216
    • /
    • 2017
  • The effect of cooling rate on precipitation hardening of a Pd-Cu-Ga-Zn metal-ceramic alloy during porcelain firing simulation was investigated and the following results were obtained. When the cooling rate was fast (Stage 0), the hardness of the alloy increased at each firing step and the high hardness value was maintained. When the cooling rate was slow (Stage 3), the hardness was the highest at the first stage of the firing, but the final hardness of the alloy after complete firing was lower. The increase in hardness of the specimens cooled at the cooling rate of Stage 0 after each firing step was caused by precipitation hardening. The decrease in hardness of the specimens cooled at the cooling rate of Stage 3 after each firing step was attributed to the coarsening of the spot-like precipitates formed in the matrix and plate-like precipitates. The matrix and the plate-like precipitates were composed of the $Pd_2(Cu,Ga,Zn)$ phase of CsCl-type, and the particle-like structure was composed of the Pd-rich ${\alpha}$-phase of face-centered cubic structure. Through the porcelain firing process, Cu, Ga, and Zn, which were dissolved in Pd-rich ${\alpha}$ particles, precipitated with Pd, resulting in the phase separation of the Pd-rich ${\alpha}$ particles into the Pd-rich ${\alpha}^{\prime}$ particles and ${\beta}^{\prime}$ precipitates composed of $Pd_2(Cu,Ga,Zn)$. These results suggested that the durability of the final prosthesis made of the Pd-Cu-Ga-Zn alloy can be improved when the cooling rate is fast during porcelain firing simulation.

Low Temperature Latent Heat Storage Material of Cooling Characteristics According to Concentration of TMA (TMA 농도에 따른 저온잠열축열물질의 냉각특성)

  • Kim, Chang-Oh;Chung, Hyun-Ho;Chung, Nak-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity are increased and COP are decreased due to supercooling of water in the course of phase change from liquid to solid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N$) of 20~25 wt% as a low temperature latent heat storage material. The results showed that the phase change temperature are increased and the supercooling degree and the specific heat are decreased according to the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25wt% has the average phase change temperature of $5.8^{\circ}C$ and the supercooling degree of $8.0^{\circ}C$, retention time of liquid phase for 651sec and specific heat of 3.499 kJ/kgK in the cooling process. This expressed good than different concentration of TMA cooling characteristic. Like this, to apply TMA 25wt%-water clathrate compound is determined by advantageous as the low temperature latent heat storage material.

An First Order Approximiate Analytical Solution to Predict Qualitative Performance Characteristics of Stirling Enging (Stirling기관(機關)의 성능예측(性能豫測)을 위한 1차원(次元) 근사해석(近似解析))

  • Kim, Tae Han
    • Current Research on Agriculture and Life Sciences
    • /
    • v.9
    • /
    • pp.87-94
    • /
    • 1991
  • An approximate analytical method to predict performance characteristics of the stirling engines in a preliminary design stage was investigated. In basic equations proposed by walker, typical temperatures of working fluids in expansion and compression spaces were treated the same as those of working fluids in heater and cooler respectively. While the temperature of working fluids in the expansion space was actually lower than that of working fluids in the heater, the temperature of working fluids in the compression space was higher than that of working fluids in the cooler. The aim of this study divided typical temperatures of working fluids in expansion and compression spaces into serval grades, and than evaluated the experimental engine. As the result, the case which working fluids temperature of expansion space was treated as lower than the heater temperature and which that of compression space was treated as higher than the cooler temperature, was much closer to the experimental value.

  • PDF