Improvement of an Analytical Method for Methoprene in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 살충제 메토프렌의 잔류분석법 개선)

  • Park, Eun-Ji;Kim, Nam Young;Park, So-Ra;Lee, Jung Mi;Jung, Yong Hyun;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • The research aims to develop a rapid and easy analytical method for methoprene using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A simple, highly sensitive, and specific analytical method for the determination of methoprene in livestock products (beef, pork, chicken, milk, eggs, and fat) was developed. Methoprene was effectively extracted with 1% acetic acid in acetonitrile and acetone (1:1), followed by the addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium acetate. Subsequently, the lipids in the livestock sample were extracted by freezing them at -20℃. The extracts were cleaned using MgSO4, primary secondary amine (PSA), and octadecyl (C18), which were then centrifuged to separate the supernatant. Nitrogen gas was used to evaporate the supernatant, which was then dissolved in methanol. The matrix-matched calibration curves were constructed using 8 levels (1, 2.5, 5, 10, 25, 50, 100, 150 ng/mL) and the coefficient of determination (R2) was above 0.9964. Average recoveries spiked at three levels (0.01, 0.1, and 0.5 mg/kg), and ranged from 79.5-105.1%, with relative standard deviations (RSDs) smaller than 14.2%, as required by the Codex guideline (CODEX CAC/GL 40). This study could be useful for residue safety management in livestock products.

Development of a Simultaneous Analytical Method for Azocyclotin, Cyhexatin, and Fenbutatin Oxide Detection in Livestock Products using the LC-MS/MS (LC-MS/MS를 이용한 축산물 중 유기주석계 농약 Azocyclotin, Cyhexatin 및 Fenbutatin oxide의 동시시험법 개발)

  • Nam Young Kim;Eun-Ji Park;So-Ra Park;Jung Mi Lee;Yong Hyun Jung;Hae Jung Yoon
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.361-372
    • /
    • 2023
  • Organotin pesticide is used as an acaricide in agriculture and may contaminate livestock products. This study aims to develop a rapid and straightforward analytical method for detecting organotin pesticides, specifically azocyclotin, cyhexatin, and fenbutatin oxide, in various livestock products, including beef, pork, chicken, egg, and milk, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The extraction process involved the use of 1% acetic acid in a mixture of acetonitrile and ethyl acetate (1:1). This was followed by the addition of anhydrous magnesium sulfate (MgSO4) and anhydrous sodium chloride. The extracts were subsequently purified using octadecyl (C18) and primary secondary amine (PSA), after which the supernatant was evaporated. Organotin pesticide recovery ranged from 75.7 to 115.3%, with a coefficient of variation (CV) below 25.3%. The results meet the criteria range of the Codex guidelines (CODEX CAC/GL 40). The analytical method in this study will be invaluable for the analysis of organotin pesticides in livestock products.

Studies on the Biochemical Features of Soybean Seeds for Higher Protein Variety -With Emphasis on Accumulation during Maturation and Electrophoretic Patterns of Proteins- (고단백 대두 품종 육성을 위한 종실의 생화학적 특성에 관한 연구 -단백질의 축적과 전기영동 유형을 중심으로)

  • Jong-Suk Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.135-166
    • /
    • 1977
  • Some biochemical features of varietal variation in seed protein and their implications for soybean breeding for high protein were pursued employing 86 soybean varieties of Korea, Japan, and the U.S.A. origins. Also, studied comparatively was the temporal pattern of protein components accumulation during seed development characteristic to the high protein variety. Seed protein content of the 86 soybean varieties varied 34.4 to 50.6%. Non-existence of variety having high content of both protein and oil, or high protein content with average oil content as well as high negative correlation between the content of protein and oil (r=-0.73$^{**}$) indicate strongly a great difficulty to breed high protein variety while conserving oil content. The total content of essential amino acids varied 32.82 to 36.63% and the total content of sulfur-containing amino acids varied 2.09 to 2.73% as tested for 12 varieties differing protein content from 40.0 to 50.6%. The content of methionine was positively correlated with the content of glutamic acid, which was the major amino acid (18.5%) in seed protein of soybean. In particular, the varieties Bongeui and Saikai #20 had high protein content as well as high content of sulfur-containing amino acids. The content of lysine was negatively correlated with that of isoleucine, but positively correlated with protein content. The content of alanine, valine or leucine was correlated positively with oil content. The seed protein of soybean was built with 12 to 16 components depending on variety as revealed on disc acrylamide gel electrophoresis. The 86 varieties were classified into 11 groups of characteristic electrophoretic pattern. The protein component of Rm=0.14(b) showed the greatest varietal variation among the components in their relative contents, and negative correlation with the content of the other components, while the protein component of Rm=0.06(a) had a significant, positive correlation with protein content. There was sequential phases of rapid decrease, slow increase and stay in the protein content during seed development. Shorter period and lower rate of decrease followed by longer period and higher rate of increase in protein content during seed development was of characteristic to high protein variety together with earlier and continuous development at higher rate of the protein component a. Considering the extremely low methionine content of the protein component a, breeding for high protein content may result in lower quality of soybean protein.n.

  • PDF

Evaluation of Intralimb Coordination in Transfemoral Amputee during Level Walking (대퇴절단인의 보행 시 하지 내 협응성 평가)

  • Chang, Yoon-hee;Jeong, Bo-ra;Kang, Sung-jae;Ryu, Jei-cheong;Mun, Mu-seong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 2016
  • The aims of this study were to evaluate the joint coordination between hip and knee joints in the transfemoral amputees, and its symmetry between sound and prosthetic limbs. Seven transfemoral amputees ($46.4{\pm}10.7-year-old$, $174.8{\pm}3.5cm$, $78.3{\pm}9.7kg$) and 7 able bodies ($24.0{\pm}4.5-year-old$, $174.5{\pm}5.9cm$, $66.9{\pm}9.4Kg$) participated in this study. They walked at a self-selected walking speed across a 10m level ground. Simultaneously angle and angular velocity in the hip and knee joint were measured by motion analysis system. Then continuos relative phase(CRP), standard deviations of CRP (CRP_SD) and symmetry index(SI) were calculated. In able bodies, there were no differences of the parameters between left and right limb(all p>0.05). However, significant differences between sound and prosthetic limb in most of the parameters, except for CRP for stance phase were shown (all p<0.05). There were differences in all SI between transfemoral amputees and able bodies (p<0.05). In conclusion, joint coordination was altered in transfemoral amputee during level walking and shown in interlimb asymmetry.

Determination of Mercury at Electrodes Modified with Poly-$[Ru(v-bpy)_3]^{2+}$ Incorporating Amino Acids (몇 가지 아미노산으로 변성한 $[Ru(v-bpy)_3]^{2+}$ 고분자 피막 전극을 이용한 수은의 정량)

  • Cha, Seong Keuk
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.8
    • /
    • pp.542-548
    • /
    • 1996
  • Electrodes modified with threonine, methionine and serine as ligands, which are incorporated by ion exchange into a polycationic film of electropolymerized $[Ru(v-bpy)_3]^{2+}$, have been employed in the determination of mercury in solution. The redox response of the surface-immobilized mercury/ligand complex was used as the analytical signal. When the polymeric film was electropolymerized, the supporting electrolytes were TBAP and $KPF_6$ to compare the morphology and anodic stripping of resulted polymer electrodes. At the case of the latter, the film had high porosity to give an easy incorporation of dopant anions into polymeric film matrix and a high sensitivity in determination of mercury ion. Especially, this polymer modified electrode exhibited possibility of multiple use in mercury determination over ten times. In all cases, calibration curves which were plotted by log of the surface coverage-normalized redox response vs. log[Hg] exhibited an excellent correlation (r=0.99) for mercury concentrations ranging from 1.0{\times}10^{-8}{\sim}1.0{\times}10^{-2}M$. At these curves relative standard deviation was 5∼8% and saturation response was not observed at high concentration region. Serine of the employed ligands had the best sensitivity in analytical application, which had greater stability constant in forming a complex with mercury than others as $pK_{Hg}=8.54$. The formation constants of threonine and methionine were respectively 7.04 and 7.80.

  • PDF

Direct Determination of Molybdenum in Simulated Nuclear Spent Fuels by Inductively Coupled Plasma Atomic Emission Spectrometry (유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 몰리브덴 분석)

  • Choi, Kwang Soon;Lee, Chang Heon;Park, Soon Dal;Park, Yang Soon;Joe, Kih Soo
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.291-296
    • /
    • 2000
  • The SIMFUEL which composition is similar to PWR nuclear spent fuels was dissolved with a acid digestion bomb. An analytical conditions of ICP-AES for the direct determination of molybdenum in the uranium matrices without separation process were investigated. Based on the effect of uranium on molybdenum intensity. the most optimum wavelengths of molybdenum were found to be 202.030 and 203.844 nm. However, the method of standard additions is applied to overcome the effects of changing background caused by analyzing the sample solutions containing high concentration of uranium and the standard calibration solutions. The relative error of two methods, direct and indirect measurements with cation exchange resin separation procedures, was less than 5%. Therefore it was possible for this procedure to directly measure molybdenum in uranium matrices without separation. And this method was also applied to the determination of several percent of molybdenum in a U-Mo alloy.

  • PDF

Effects of Self Esteem, Impulsive Behavior and Mental Health on Cellular Phone Addiction of Adolescents (청소년의 자아존중감, 충동성 및 정신건강이 휴대전화 중독에 미치는 영향)

  • Lee, Hea-Shoon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.200-210
    • /
    • 2014
  • Purpose: The purpose of this study was done to investigate the relationship between self esteem, impulsive behavior and mental health among adolescents who were cellular phone addiction and those who were not. Methods: The data were collected using questionnaire from the sample of 239 middle school students. The data were collected from April 8 to 19, 2013. Data were analyzed using frequencies, means, ${\chi}^2$-test, Fisher's exact test, t-test and logistic regression analysis with SPSS 20.0. Results: Firstly, Significant differences were found for grade, sex, period, buying motives, the number of the messages/day, use, phone bill, callers between students who were cellular phone addiction and those who were not. Secondly, Self esteem for the cellular phone addiction were lower than for those in the non-addiction group, and impulsive behavior and mental health were higher. Thirdly, The logistic regression analysis revealed that self esteem, non-planning impulsiveness, mental health total, grade, sex, period, and the number of the messages/day significantly associated with being a cellular phone addiction. Conclusions: The result of this study offer basic data for the development of intervention programs to prevent adolescents cellular phone addiction.

Matrix Modification for Graphite Furnace Atomic Absorption Spectrophotometric Determination of Volatile Elements (Ⅰ). Determination of Trace Lead by Graphite Furnace Atomization (휘발성 원소들의 원자흡수 분광분석을 위한 매트릭스 개선에 관한 연구 (제 1 보). 흑연로 원자화에 의한 흔적량 납의 정량)

  • Choi, Jong Moon;Choi, Ho Sung;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.3
    • /
    • pp.204-212
    • /
    • 1995
  • The graphite furnace atomic absorption spectrophotometric determination of trace lead in water samples was studied using matrix modifiers. In order to modify the sample matrix, the type and optimum amount of the modifier were investigated with a given concentration of Pb solution. In fact, if the matrix is not modified, lead has low ashing and atomization temperatures as to give a low absorbance with bad reproducibility because of its volatility. Therefore, optimum modifiers should be used to stabilize the atomization. In this work, the ashing and atomization temperatures were raised from 400 and $1800^{\circ}C$, to 1,000 and $2000^{\circ}C$, by the addition of palladium to 50 ng/mL lead solution as a modifier. The concentration of palladium was 5.0 ${\mu}g/mL$ in the modified solution. Furthermore, if 1.5 ${\mu}g/mL$ of aluminum was mixed with the palladium modifier as an auxiliary modifier, the ashing temperature could be increased $150^{\circ}C$ additionally. With such a treatment, the sensitivity was improved more than 5 times of the solution unmodified and the reproducible results of less than 5% RSD were obtained in the samples of university's waste water and pipe-washing tap water. It could be concluded that this procedure was quantitative in the determination of trace lead from the recoveries of more than 88% obtained in the samples in which a given amount of lead was spiked.

  • PDF

Application of Microwave Digestion Pretreatment Techniques for ICP-AES Analysis of Used Monolithic Automobile Catalysts Having Platinum Group-Metals and Silicates (백금족 금속과 규산염을 포함하는 모노리스형 자동차 폐촉매의 ICP-AES 분석을 위한 극초단파 분해 전처리 기법의 응용)

  • Kim, Choong-Hyon;Woo, Seong Ihl;Jeon, Sung Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.568-575
    • /
    • 1999
  • Two different digestion procedures for the simultaneous determination of major and platinum-group element(PGE) in spent automobile catalysts containing PGE and silicates by inductively coupled plasma atomic emission spectrometry(ICP-AES) are compared. Combinations of mixed aids using HF, $HNO_3$, HCl, $HClO_4$, $H_2O_2$, and $H_3BO_3$ are utilized for the hot plate dissolution method and the closed-vessel microwave digestion method, The latter method has been shown to be relatively superior in terms of recovery, analysis time, and amount of aqua regia (3 parts HCl + part $HNO_3$ required to dissolve PGE in comparison with conventional open vessel hot-plate dissolution. The best results were drawn from the following conditions: In closed Teflon PFA vessels under microwave heating with temperature/pressure regulation, a 0.25 g portion of sample was digested in 2 mL of HF, 2 mL of $HNO_3$ and 6mL of HCl under the pressure of 200 psi(13.79 bar) at $180^{\circ}C$ for 1hr, followed by a second digestion stage with 16 mL of 5%(w/v) boric acid under the pressure of 20 psi(1.38 bar) at $100^{\circ}C$ for 10 min. After the microwave heating, the sample was post-treated with 10 mL of aqua regia twice by hot-plate heating. This condition gives the PGE recovery within 85~110% and the relative standard deviations within 2%. The method developed can therefore be regarded as an alternative method for routine analysis of spent automobile catalysts.

  • PDF

Self-Sensing of Single Carbon Fiber/Carbon Nanotube-Epoxy Composites Using Electro-Micromechanical Techniques and Acoustic Emission (전기적-미세역학시험법과 음향방출을 이용한 단일 탄소섬유/탄소나노튜브-에폭시 나노복합재료의 자체-감지능)

  • Park, Joung-Man;Jang, Jung-Hoon;Wang, Zuo-Jia;Kwon, Dong-Jun;Park, Jong-Kyu;Lee, Woo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.411-422
    • /
    • 2010
  • Self-sensing on micro-failure, dispersion degree and relating properties, of carbon nanotube(CNT)/epoxy composites, were investigated using wettability, electro-micromechanical technique with acoustic emission(AE). Specimens were prepared from neat epoxy as well as composites with untreated and acid-treated CNT. Degree of dispersion was evaluated comparatively by measuring volumetric electrical resistivity and its standard deviation. Apparent modulus containing the stress transfer was higher for acid-treated CNT composite than for the untreated case. Applied cyclic loading responded well for a single carbon fiber/CNT-epoxy composite by the change in contact resistivity. The interfacial shear strength between a single carbon fiber and CNT-epoxy, determined in a fiber pullout test, was lower than that between a single carbon fiber and neat epoxy. Regarding on micro-damage sensing using electrical resistivity measurement with AE, the stepwise increment in electrical resistivity was observed for a single carbon fiber/CNT -epoxy composite. On the other hand, electrical resistivity increased infinitely right after the first carbon fiber breaks for a single carbon fiber/neat epoxy composite. The occurrence of AE events of added CNT composites was much higher than the neat epoxy case, due to micro failure at the interfaces by added CNTs.