• Title/Summary/Keyword: 상관식

Search Result 3,758, Processing Time 0.03 seconds

A Generalized Empirical Correlation on the Mass Flow Rate through Adiabatic Capillary Tubes with Alternative Refrigerants (대체냉매를 적용한 일반화된 모세관의 유량예측 상관식)

  • 최종민;장용희;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.744-750
    • /
    • 2003
  • The performance of adiabatic capillary tubes are measured to provide the database for a generalized correlation. Test conditions and capillary tube geometries are selected to cover a wide range typically observed in air-conditioning and heat pump applications. Based on extensive experimental data for R22, R290, and R407C measured in this study, a generalized correlation for refrigerant flow rate in adiabatic capillary tubes is developed by implementing dimensionless parameters for tube inlet conditions, capillary tube geometry, and refrigerant properties. The correlation yields good agreement with the present data for R22, R290, and R407C with average and standard deviations of 0.9% and 5.0%, respectively. In addition, approximately 97% of the data for Rl2, R134a, R152a, R410A, and R600a obtained in the open literature are correlated within a relative deviation of $\pm$ 15%.

Derivation of the Critical Minimum Values of the Multiple Correlation Coefficient for Augmenting Hydrologic Samples (수문자료 확충을 위한 다중상관계수의 한계최소치 유도)

  • 허준행
    • Water for future
    • /
    • v.27 no.1
    • /
    • pp.133-140
    • /
    • 1994
  • The augmenting hydrologic data using a correlation procedue has been used to improve the estimates of the mean and variance at the site of interest with short record when one or more nearby sites with longer records are available. The variance of the unbiased maximum likelihood estimator of ${{\sigma}_v}^2$ derived by Moran based on the multivariate normal distribution is modified into the form of Matalas and jacobs for the bivariate normal distribution to get the critical minimum values of the multiple correlation coefficient which give the improvement for estimation the variance at the site of interest. Those values are tabulated for various lengths of records and the number of sites.

  • PDF

Evaluation of Heat Transfer Enhancement Performance for Wire Coil Inserts in Horizontal Smooth Tubes (수평 평활관 내부에 삽입한 와이어코일 인서트에 대한 전열성능평가)

  • 남상철;이주동;이상천
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.202-211
    • /
    • 2000
  • 본 연구는 다양한 각도를 가지는 와이어코일을 사용하여 관내 단상 열전달 촉진 및 압력강하 특성 실험을 수행하였다. 작동유체는 순수 물과 에틸렌글리콜을 체적비율로 50% 혼합하여 사용하였으며, 시험부 관지름은 11mm와 13.88mm이고, 시험부 길이는 760mm를 사용하였다. 평활관과 와이어코일을 삽입한 열전달촉진관에 대한 관내 열전달계수와 마찰계수는 실험에서 측정한 온도, 유량, 압력강하 값을 기초로 구하였다. 와이어코일에 대한 거친표면해석을 수행하였으며, 그 결과를 거칠기 래이놀즈수에 대한 운동량전송 거칠기함수와 열전달 거칠기함수로 표현하였으며 이에 대한 상관식을 제시하였다. 이 상관식들은 거칠기 레이놀즈수, 코일 각도, 프란틀수의 함수로 표현하였다.

  • PDF

Performance Comparison of Correlations of the Saturated Liquid Densities for Pure Substances (순수물질에 대한 포화액체밀도 상관식의 성능비교)

  • Lee, Kyoung-Youl;Park, Kyoung-Kuhn
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.373-379
    • /
    • 2005
  • A few correlation equations of the saturated liquid density are reviewed and a new equation is proposed. Performance of each equation is examined using the data listed in the ASHRAE table for 22 pure substance refrigerants. The new four-parameter equation yields an average absolute deviation of 0.03% for 22 refrigerants. Performance of the new four-parameter equation is found to be equivalent to those of the existing equations such as Hou-Martin equation(0.03%) and Iglesias-Silva-Hall equation(0.08%).

  • PDF

Effects of Working Fluid Filling Ratio and Heat flux on Correlations of Heat Transfer Coefficient in Loop Thermosyphon (루프 써모사이폰에서 작동유체 충액률과 열유속이 열전달계수의 상관식에 미치는 영향)

  • 장기창;이기우;이영수;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.462-473
    • /
    • 2001
  • Due to the coupling between momentum and energy transport theoretical analysis of the loop performance is very complicate, therefore it is necessary that these problems be solved by experimental investigation before applying th loop thermosyphon to heat exchanger design. The evaporator and condenser of the loop thermosyphon were made of carbon-steel, and distilled water was used as working fluid in the experiments. From the experimental data correlations of heat transfer coefficient for evaporator and condenser sections were obtained. For heat fluxes in th range of 13~78kW/$m^2$, the correlation equations of heat transfer coefficients in evaporator and condenser predict the experimental behavior to within $\p$\pm$5% and\;\pm20$% respectively.

  • PDF

A study of Hybrid Alarm Correlation in SDH Networks (동기식 전송망(SDH)에서 경보 상관관계 적용방안)

  • Lee, In-Soo;Lee, Byeong-Wook;Lee, Sung-Woo;Kim, Do-Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.161-162
    • /
    • 2006
  • 동기식 전송망에서 발생되는 장애는 장비의 구성정보에 따라 다양한 알람정보를 발생시킨다. 전송망에서 발생되는 알람은 장애 원인으로 추정되는 근원알람과 장애로 인해 파생되는 파생알람으로 분류할 수 있다. 본 고는 이러한 분류체계를 기반으로 알람 상관관계 기법을 적용한 네트워크 장애관리시스템 구현 사례를 제시한다. 적용된 상관관계 방법은 Rule 기반의 접근방법 및 Codebook 기반의 접근방법을 접목한 hybrid 상관관계 방법을 적용하였고, 복잡성을 최소화 하기 위해 회선 기반의 grouping 기법을 사용하였다.

  • PDF

Correlations of Heat Transfer and Pressure Drop for Offset Strip Fins (옵셋 스트립 핀에서의 열전달 및 압력 강하 상관식)

  • Kim, Min-Soo;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2274-2279
    • /
    • 2008
  • This paper numerically investigates thermo-flow characteristics of offset strip fins to obtain a correlation of heat transfer and pressure drop. The flow is divided into three regimes, i.e. laminar, transition and turbulent. The predicted j and f values from the SST k-w turbulence model agree with previous correlations with the error less than 20% in transition and turbulent regimes. Prandtl number is varied from 0.5 to 40 and a correlation to predict heat transfer and pressure drop for offset strip fins is suggested.

  • PDF

Performance Assessment of Refrigerant Vapor-Pressure Equations with Two Adjustable Parameters (두 개의 가변 변수가 있는 냉매 증기압 상관식의 성능 평가)

  • Park, Kyoung-Kuhn
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-135
    • /
    • 2012
  • Performance of various temperature-dependent vapor-pressure equations with two adjustable parameters is assessed. These are Antoine, Miller, Zia-Thodos, Mejbri-Bellagi and other 10 equations. The equations are fitted to correlate the data from NIST Chemistry WebBook for 43 pure substance refrigerants from the critical point to the triple point. It was found that the Mejbri-Bellagi equation yields the lowest average absolute deviation of 0.37% compared with that of 0.58% of the Miller equation which is known to give better fit to experimental data than the Antoine equation(1.42%) does.

Study on characteristics of CSOs in urban area -Focus on Pyungchang catchment of Hongje basin (도시지역 합류식 하수관거 월류수 발생특성 연구 - 홍제천 평창배수분구을 중심으로)

  • Oh Kyung-Seok;Ho Jong-Kwang;Hwang Byung-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.284-287
    • /
    • 2004
  • 홍제천 유역의 평창 배수분구를 대상으로 합류식 하수관거 월류수의 발생특성을 파악하고자 유량 및 오염물질 발생경향, 오염물질별 상관관계, 연간 강우유출 오염부하량 등에 대하여 살펴보았다. 강우시 오염물질의 초기세척현상은 누적오염 부하량비를 이용하여 분석하였으며, 모든 수질항목에 대하여 초기유출현상이 나타났으며, 초기 $20\%$ 유출 유량에서 오염부하가 $30\%$ 정도로 유출되고 있는 것으로 분석되었다. 또한 수질항목별 상관계수를 보면, 건기시의 상관계수는 COD와 SS가 0.4857, 월류수의 경우에는 SS와 TN의 상관계수가 0.7723으로 가장 크게 나타났다. 연간 강우에 의하여 방류선으로 배출되는 면적당 오염부하는 COD 1,202kg/ha/yr SS 494kg/ha/yr로 산정되었다.

  • PDF

Study on Characteristics of CSOs in Asan City (합류식 하수관거 월류수 발생특성 연구 - 아산시 모종처리구역을 중심으로)

  • Oh Kyung Seok;Ho Jong-Kwang;Kim Kyung-Won;Hwang Byung-Gi
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.278-280
    • /
    • 2004
  • 본 연구에서는 아산시의 모종처리구역을 대상으로 합류식 하수관거 월류수의 발생특성을 파악하고자 유량 및 오염물질 발생경향, 오염물질별 상관관계 등에 대하여 살펴보았다. 조사 결과, 강우시 월류 발생초기의 오염물질의 농도는 강우에 의한 초기세척현상(First Flush)에 의해 상당히 높게 나타났으며, 강우초기의 높은 오염물질의 농도는 강우에 의해 희석되어 일시적으로 낮아졌다가 높은 강우강도에 의하여 급격히 상승하였으며, 이후 오염물질의 농도는 유량의 감소에 따라 점차적으로 감소하는 것으로 나타났다. 또한 수질항목별 상관계수를 보면, SS와 TP의 상관계수가 가장 크게 나타났으며, COD와 TP, SS와 COD의 순으로 상관계수가 높은 것으로 나타났다.

  • PDF