• Title/Summary/Keyword: 삼첨판

Search Result 177, Processing Time 0.023 seconds

Three-dimensional Reconstruction of Tricuspid Annulus with the Duran Ring (Duran Ring을 이용한 삼천판륜의 삼차원적 재건술)

  • Yoo Dong Gon;Kim Chong Wook;Park Chong Bin;Choo Suk Jung;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.1 s.246
    • /
    • pp.88-90
    • /
    • 2005
  • Tricuspid annuloplasty with the flexible Duran ring may result in a physiologic repair while maintaining the dynamic morphology of the tricuspid annulus. A method for a durable three-dimensional tricuspid annular reconstruction, which retains the plasticity and orifice area of the tricuspid annulus, is described.

A Case Report of Surgical Management of Tricuswpid Valve Endocarditis (삼첨판막에 국한된 심내막염 환자의 치험 1례)

  • 김준현;서동만
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.55-58
    • /
    • 1998
  • Surgical treatment is recommended in tricuspid valve endocarditis not responding to antibiotics or presenting severe heart failure. However, risk of early prosthetic valve endocarditis especially in drug addictors is principal concern in the treatment. A 37 year-old man with tricuspid valve endocarditis underwent staged operation of primary tricuspid valvulectomy and secondary bioprosthetic valve implantation successfully. We report it with references of literature.

  • PDF

Long-Term Clinical Results of Tricuspid Valve Replacement (삼첨판막 대치술의 장기간 임상성적)

  • 임상현;홍유선;유경종;강면식;김치영;조범구;장병철
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.328-334
    • /
    • 2004
  • There are only limited numbers of reports about long-term results of tricuspid valve replacement(TVR) with bioprosthetic and mechanical prostheses. We analyzed risk factors for tricuspid valve replacement and compared long-term clinical results of bioprosthetic and mechanical valves in tricuspid position. Material and Method: We reviewed 77 cases of TVR, which were performed between October 1978 and December 1996. Mean age was 38.8 15.9 years. Bioprostheses were implanted in 26 cases and mechanical prostheses were implanted in 51 cases. Result The operative mortality was 15.6% and late mortality was 12.3%. Survival for bioprosthetic and mechanical valve group at 5, 10 and 13 years was 81.3% vs. 100%, 66.1% vs. 100%, 60.6% vs. 100% (p=0.0175). Free from valve related re-operation for bioprosthetic and mechanical valve group at 5, 10 and 13 years was 100% vs. 93.9%, 100% vs. 93.9% and 58.3% vs. 93.9% (p=0.3274). Linealized incidences of valve related re-operation for bioprosthetic and mechanical valve group was 2.27 %/patient-years and 1.10 %/patient-years. Risk factor analysis showed that presence of preoperative ascites, hepatomegaly larger than 2 finger breaths, poor preoperative NYHA functional class and number of tricuspid valve replacement were risk factors for early mortality, and the use of bioprosthetic valve and number of open heart surgery were risk factors for late mortality. Conclusion: Long-term survival of mechanical valve was superior to bioprosthetic valve in tricuspid position. We recommend mechanical valve in tricuspid position if the patient can be closely followed up.

A Study of Electrocardiographic Change and Tricuspid Competence after Temporary Detachment for Closure of Ventricular Septal Defect (삼첨판막절개아 심실중격결손증의 수술 이후의 삼첨판막의 기능에 대한 연구)

  • 정성운;박준호;김종원
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.633-637
    • /
    • 2003
  • Sometimes temporary tricuspid valve detachment is applied for closure of ventricular septal defect to facilitate good exposure and avoiding ventriculotomy, but most surgeons hesitate to do it in the fear of tricuspid incompetence. Moreover in recent textbooks the technique of temporary tricuspid detachment is only described for exceptional situations and is not further analysed or commented on. Material and Method: Retrospective study was carried out in all 11 patients operated between 1985 to 1994, with preoperative data and postoperative course and recent echocardiographic and electrocardiographic data. Result: On the basis of the area of the color flow jet, tricuspid valvular regurgitation was graded as none in 9 and trivial in 2, and significant electrocardiographic heart block did not developed in any patients. Conclusion: Takedown and attachment of the tricuspid valve is a safe and effective technique that improves exposure for ventricular septal defect, and does not adversely effect tricuspid valve competence and electrocardiography.

Severe Tricuspid Insufficiency after Correction of Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery(ALCAPA) (ALCAPA 교정후 발생한 심한 삼첨판 폐쇄부전)

  • 백만종;김웅한;오삼세;류재욱;공준혁
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.724-728
    • /
    • 2001
  • We report a case of an 8 years and 11 month-old male patient who had developed severe tricuspid insufficiency(TI) after correction of anomalous origin of the left coronary artery from the pulmonary artery(ALCAPA). Transthoracic echocardiogram and coronary angiography confirmed ALCAPA, ischemic mitral regurgitation and trivial TI. He underwent direct reimplantation of the left coronary artery to the aortic root by using additional cannulation at the main pulmonary artery for arterial inflow and cardioplegia delivery to the left coronary artery. After the correction of ALCAPA, transesophageal echocardiogram(TEE) revealed good antegrade flow at the aortic implantation site of the left coronary artery and severe TI(Gr III-IV/IV). Cardiopulmonary bypass was reestablished and tricuspid valve was repaired with Kay-type annuloplasty, artificial chordae formation and chordal shortening plasty. The postrepair TEE revealed trivial to mild TI.

  • PDF

Mid-term and Long-term Outcomes of Posterior Plication Annuloplasty(Modified Davila Annuloplasty) for Functional Tricuspid Regurgitation (기능성 삼첨판막부전증에 대한 삼첨판후판륜주름술(Davila Technique)의 중장기결과)

  • Lee, Mi-Kyung;Kim, Jong-Hun;Kim, Min-Ho;Jo, Jung-Ku;Choi, Jong-Bum
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.580-585
    • /
    • 2008
  • Background: Many types of tricuspid annuloplasty are used in surgical correction of functional tricuspid regurgitation (FTR). We evaluated the mid-term and long-term outcomes in patients treated with a posterior annular plication technique (a modified Davila technique) for FTR. Material and Method: Between January 1991 and August 2006, 58 adult patients (male, 22; female, 36) with FTR of grade 2/4 or more or with tricuspid annular dilatation of more than 5.0cm in diameter, even with an FTR of less than grade 2, had received a posterior annular placation. Preoperatively, 26 patients (44.8%) had a grade 3 or more FTR. All patients had received a mitral valve replacement, and 20 (34.5%) had concomitant aortic valve replacement. Result: During the mean follow-up period of $101.4{\pm}51.6$ months, FTR disappeared or remained trivial in 28 patients (49.1%), was grade $2{\sim}3$ (${\geq}$grade 2 and $2.66{\pm}0.73\;vs.\;0.82{\pm}0.89$; p<0.0001). Patients did not require a second surgery for FTR and did not show further FTR aggravation. Conclusion: The modified Davila posterior annular plication technique for FTR has reasonable mid-term and long-term results and is a useful surgical procedure.

Cone Reconstruction for Tricuspid Valve Repair in a Patient with Ebstein's Anomaly - A case report - (Cone 재건술을 이용한 엡스타인 기형의 삼첨판막 성형술 - 1예 보고 -)

  • Lee, Cheul;Kwak, Jae-Gun;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.509-512
    • /
    • 2009
  • Ebstein's anomaly is a complex congenital defect of the tricuspid valve and right ventricle. Various surgical methods to repair the regurgitant tricuspid valve have been reported, and most of them depend on monocuspidalization with using the anterior leaflet. We report here on our first experience with Ebstein's anomaly in a 31-year-old female patient who underwent cone reconstruction of the tricuspid valve with using three leaflets.

Tricespid Regurgitation Due to Rupture of a Chordae in Newborn -A Report of One Case (신생아에서의 건삭 파열에 의한 삼첨판 폐쇄 부전 -1례 보고-)

  • 김태이;이장훈
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.927-931
    • /
    • 1997
  • Tricuspid regurgitation due to rupture of a chorda is a rare disease in newborns. Recently, we experienced one day old male with tricuspid regurgitation due to rupture of a chorda of anterior papillary muscle, and who had suffered from severe hypoxemia, acidosis, cyanosis, and bradycardia. Preoperative diagnosis was pulmonary atresia with intact ventricular s ptum, massive tricuspid regurgitation, and patent ductus arteriosus by echocardiogram, which demonstrated no flow through the pulmonic valve. At operation, the pulmonic valve was intact and a chorda of anterior papillary muscle was ruptured. Tricuspid regurgitation was corrected successfully with reconstruction of the chords. Postoperative course was complicated by pneumonia and sepsis, but the infant recovered and discharged at postoperative 20 days.

  • PDF

Tricuspid Valve Repair for Tricuspid Valve Insufficiency Following a Cardiac Stab Injury - One case report - (심장 자상 후에 발생된 삼첨판막 폐쇄부전의 삼첨판막 성형술 - 1예 보고 -)

  • Kim, Dong-Hyun;Lee, Seong-Jin;Lee, Chol-Sae;Lee, Kihl-Rho;Lee, Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.376-379
    • /
    • 2007
  • A 51-year-old male was admitted three month previously with a cardiac stab injury and he underwent direct cardiac repair He had no problem after this event. He complained of dyspnea that stalled 2 months after the original injury. Echocardiography showed severe tricuspid regurgitation and so, chordac replacement and ring annuloplasty was performed. Herein we report on a case of tricuspid valve repair for treating tricuspid insufficiency following a cardiac stab injury.

The Early Results of Tricuspid Valvuloplasty with Using the Edwards MC3 Annuloplasty System (Edwards MC3 Annuloplasty System을 이용한 삼첨판 성형술의 조기 성적)

  • Oh, Tak-hyuck;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik;Kim, Dae-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.28-33
    • /
    • 2009
  • Background: Functional tricuspid regurgitation (TR) greater than or equal to a mild grade requires tricuspid valvuloplasty, and tricuspid valvuloplasty with ring annuloplasty has shown good outcomes. We report here on our early experience with the Edwards $MC^3$ annuloplasty system (Edwards LifeSciences, Irvine, CA). Material and Method: From November 2004 to July 2006, 72 patients with tricuspid annular dilatation and TR underwent tricuspid valvuloplasty with using the Edwards $MC^3$ annuloplasty ring. Sixty-eight patients were operated on via median sternotomy and four patients were operated on using robotic assisted minimal invasive thoracotomy. The patient population included 21 males and 51 females and their mean age was $53.9{\pm}12.3$. The mean grade of TR, as assessed by the preoperative echocardiography, was $2.2{\pm}1.0$. The mean NYHA functional class was $3.1{\pm}0.8$. The mean left ventricular ejection fraction was $57.0{\pm}9.9$%. Result: The TR and NYHA functional class, as assessed by postoperative echocardiography, was significantly reduced (mean=$0.4{\pm}0.6$ and $2.0{\pm}0.7$, respectively p<0.001). There was one case of hospital mortality. One patient required permanent pacemaker insertion for third degree atrioventricular block. Conclusion: Our study shows that the Edwards $MC^3$ remodeling ring is easy to implant and it effectively corrects functional TR with excellent clinical and echocardiographic outcomes. Further follow-up and a larger clinical series are required to establish the long-term stability of this repair technique.