• Title/Summary/Keyword: 산화제 개폐밸브

Search Result 28, Processing Time 0.023 seconds

Development of a Two-Step Main Oxidizer Shut-off Valve (2단계 개방 연소기 산화제 개폐밸브 개발)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.8
    • /
    • pp.704-710
    • /
    • 2017
  • The supply of the liquid oxygen into a rocket combustor is simply controlled by the 'on' and 'off' positions of a main oxidizer shut-off valve. However, the partially opened position of a three-position valve can control and optimize the engine start transients by regulating the liquid oxygen flow rate during the start-up of the engine. In this paper, the design and performances of a three-position pneumatic poppet valve, which is intended to be employed in liquid rocket engines, have been presented.

On the Force Balance of a Main Oxidizer Shutoff Valve (산화제 개폐밸브의 힘평형에 관한 연구)

  • Hong, Moon-Geun;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.14-17
    • /
    • 2008
  • A poppet type shutoff valve under the pneumatic control has been adapted for the MOV (Main Oxidizer shutoff Valve) for KSLV (Korea Space Launch Vehicle). The MOV controls the supply of liquid oxygen into the combustion chamber just by opening and shutting operations. The poppet part of the poppet valves is usually connected with the piston, but on the other hand that of the MOV is separated and just contacted with the piston in order to secure the flexibility of the valve design. For the prevention of the collision with valve body by an undesirable movement of the piston part, it is necessary to evaluate the force during the valve closing. The analysis of the force balance of the MOV at the moment of the valve closing have been performed and some important design parameters for the force balance control have been introduced.

  • PDF

Operating Characteristics of a Main Oxidizer Shut-off Valve According to Operating Times (작동 횟수에 따른 연소기 산화제 개폐밸브 작동 특성)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-83
    • /
    • 2020
  • The operating characteristics of a main oxidizer shut-off valve have been examined by life-cycle tests in which the valve operates as many times as is required at room and cryogenic temperatures. It is shown that there is no significant change of the operating characteristics in the course of the life-cycle tests. The critical pressures and principal forces, which represent the operating characteristics, differ at each operating time by less than about 3%. These qualified operating characteristics of the valve are expected to play an indispensible role in the stable startup and shutdown of a liquid rocket engine.

Study on the improvement in Cv of a Main Oxidizer shut-off Valve (CC 산화제 개폐밸브 유량계수 향상에 관한 연구)

  • Hong, Moon-Geun
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • MOV(Main Oxidizer shut-off Valves) control the combustion of launch vehicle systems by the supply and the isolation of liquid oxygen to a main combustion chamber in launch vehicle systems. Moreover, in the steady operational state, the MOV should secure a constant flow rate of liquid oxygen for combustion instability in the combustion chamber. Concerning the development of MOV, TM(Technology Model) has been manufactured and normal operations of the valve have been verified. However, the Cv of TM has been proved to be too low as compared with a design specification value. Therefore, CFD analysis have been performed by modification of the configurations of TM in order to increase sufficiently Cv of EM(Engineering Model), which is the following model of TM. The modifications of TM configurations such as partial scale-up of valve, increase of stroke length, and outlet angle of 120o would result in a considerable augmentation of Cv. It has been verified by flow capacity tests that the improved Cv of EM is min. 212, which is higher than Cv of TM, 161 by about 32%.

  • PDF

Opening Characteristics of a Main Oxidizer Shut-off Valve at Different Valve Inlet Pressures (밸브 입구 압력 변화에 따른 연소기 산화제 개폐밸브 열림 특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.801-807
    • /
    • 2020
  • Opening characteristics of a main oxidizer shut-off valve at different valve inlet pressures have been experimentally investigated. The pilot pressure at the moment of the valve opening increases linearly with increasing the valve inlet pressure and the increased pilot pressure reduces the valve travel time. As the pilot pressure increases at the moment of valve opening, the time to start opening the valve is delayed resulting in increasing the valve opening time. With the increment of the valve inlet pressure, the valve opening time is mainly determined by the time required for the pilot pressure to start opening the valve. Therefore the design of a pilot gas supply system can readily control the valve inlet pressure at the valve opening as well as the amount of oxidizer supplied to a combustion chamber during the engine startup.

Performance Characteristics of a Main Oxidizer Shutoff Valve for Liquid Rocket Engines (액체로켓엔진용 연소기 산화제 개폐밸브 성능 특성)

  • Jeong, Daeseong;Hong, Moongeun;Han, Sangyeop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.28-35
    • /
    • 2017
  • A main oxidizer shutoff valve controls the supply of the oxidizer flow into the combustion chamber of a liquid rocket engine. This shutoff valve also carries out the pre-chilling of oxidizer supply lines by permitting recycling flow for stable transient start of the engine. In the present paper, the flow tests for the recycling line of the valve were conducted in order to evaluate the cooling performance of the main oxidizer shutoff valve. In addition, cryogenic life-cycle tests were performed with an assumption of the increase of spring constant with increasing valve operating times due to ductile-brittle transition effects.

Improvement of a Flow Coefficient for the Recirculation Chill-down Flow in a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 재순환예냉 유로의 유량계수 개선)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.89-95
    • /
    • 2017
  • The improvement of a flow coefficient for the recirculation chill-down flow in a main oxidizer shut-off valve has been presented. The flow coefficient, which is mainly affected by the recirculation outlet port size and the configuration inside the valve, has been predicted with measured flow coefficient values. The comparison of experimentally measured flow coefficient with the predicted value shows the effect of valve inside configuration on the flow coefficient. Consequently, the flow coefficient is twice the previous value and about 75% of the pressure loss assigned to the main oxidizer shut-off valve can be used for additional pressure losses for other components in the recirculation chill-down system of a launch vehicle.

A Study on the Force Balance of a Main Oxidizer shutoff Valve (산화제 개폐밸브의 힘평형에 관한 연구)

  • Jeon, Jae-Hyoung;Hong, Moon-Geun;Kim, Hyun-Jun;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.812-818
    • /
    • 2009
  • A MOV(Main Oxidizer shutoff Valve) controls the flow rate of liquid oxygen into the rocket combustor by opening and shutting operations piloted by a pneumatic force. In order to improve the effective design for sealing parts of poppet and piston assemblies, the poppet assembly has been designed to be just contacted with the piston assembly. However, to avoid a gap at the poppet/piston contact surface and to evaluate the MOV operating performance, an analyze on the force balance during the closing motion have been performed. For the accuracy of the analysis, the friction forces and the hydraulic forces have been respectively obtained by experiments and CFD analysis. Through the analysis, some important design parameters such as the spring constant, poppet friction and orifice size in the force balance have been introduced and the required operation performance of the MOV has been proved feasible.

Study on Flow Property and Structural Analysis of Gas Generator Oxidizer On/Off Valve (가스발생기 산화제 개폐밸브의 내부 유동특성 및 구조해석에 관한 연구)

  • Lee, Jongl-Yul;Huh, Hwan-Il;Ahn, Yang-Woo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.6
    • /
    • pp.48-55
    • /
    • 2009
  • The purpose of using Gas Generator Oxidizer On/Off Valve(GOV) is to control opening and closing of oxidizer mass flow. This paper describes analytical results of flow and structural properties for four different GOV models, using commercial software such as Fluent(Ver. 6.3.26) and NASTRAN(2005 r.2), PATRAN(2005 r.2). Analytical results show that GOVs could generate 2.3~3.8 kg/s of oxidizer mass flow rate and come up with 1.09~1.42 of safety factor.

Study for the Development of a Main Oxidizer Shut-off Valve for Liquid Rocket Engines (발사체 연소기용 산화제 개폐밸브의 핵심요소 기술 개발)

  • Kim, Dohyung;Hong, Moongeun;Park, Jaesung;Lee, Soo Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.113-119
    • /
    • 2013
  • A main oxidizer shut-off valve (MOV) controls the supply of cryogenic liquid oxygen to the combustion chamber of liquid rocket engines by on/off operations. The main subjects to be introduced are not only the valve transient response during valve on/off procedures but also the characteristics of pneumatic and seat/poppet parts as core technologies in the development of the MOV, which is expected to be adopted for the Korea Space Launch Vehicle II. It is shown that the analytical prediction of the transient valve travel is in good agreement with experimental results. Friction and elastic forces on the valve moving part are quantitatively evaluated by structural analysis.