• Title/Summary/Keyword: 산소 센서

Search Result 255, Processing Time 0.027 seconds

Fabrication and Characteristics of Oxygen Gas Sensor using Fluoride Compaunds (불화물을 이용한 산소센서의 제조및 특성)

  • 이재현;홍영호;장동근;이병택;김태훈;이덕동
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1993.11a
    • /
    • pp.69-71
    • /
    • 1993
  • Fluoride compound potentiometric cell oxygen sensors were fabricated for the measurement of oxygen pressure in the low temperature range (300。K-500。K). The disk type sensors consist of a reference Air(0$_2$):Ag, a solid electrolyte SrF$_2$, and a sensing metel Ag electrode. And the buried reference electrode type sensor have a NiO/Ni reference electrode. The open circuit emf of the cell showed high sensivity to oxygen gas (60mv) at the measuring temperature 20$0^{\circ}C$. Also, The buried reference electrode type sensor showed 30mv from 1% to 10% oxygen pressure range.

  • PDF

Research on Real-time Stream Data Monitoring for BodyNet (BodyNet 에서의 스트림 데이터 실시간 모니터링 기법의 연구)

  • Lee, Seul-A;Choi, Ok-ju;Lee, Minsoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.126-129
    • /
    • 2010
  • WBAN(Wireless Body Area Network)기반의 의료 응용으로 실시간 모니터링 시스템을 구현하였다. 특히 산소포화도 생체 센서들로부터 연속적으로 전송되는 스트림 데이터에 대해 다양한 조건을 포함하는 질의들이 실행 되는데 이러한 실시간 모니터링 질의들을 효율적으로 식별하기 위한 질의 인덱스를 설계하였다. 매번 모든 질의들을 실행하기에는 시간이 많이 걸리기 때문에 Interval Skip List 를 이용하여 빠르고 효율적으로 식별하도록 설계하였다. 이로써 위급한 상황의 환자의 건강에 문제가 생겼을 때 신속하게 대처할 수 있는 환경을 제공한다. 본 논문에서는 방대한 양의 스트림 데이터와 이 데이터를 실시간으로 감시할 수 있도록 Interval Skip List 를 스마트 메디컬 스페이스(m-MediNet)에 적용한 방법을 기술하고 있다.

Real-time Stream Data Monitoring Using Windows (윈도우를 이용한 스트림 데이터의 실시간 모니터링 기법)

  • Han, Xiaoyue;Choi, Ok-Ju;Lee, Min-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.1231-1233
    • /
    • 2011
  • WBAN(Wireless Body Area Network)과 같은 스트림 데이터의 환경에서는 데이터가 아닌 질의들이 등록되어 있고 데이터들이 끊임없이 시스템에 도착한다. 때문에 도착한 데이터에 대해서 처리할 수 있는 질의만을 찾아 해당 질의들만을 수행하도록 해서 시스템의 질의 부담을 덜어주는 방법이 필요하다. 기존의 단순하고 단편적인 질의의 문제점을 해결하고자 본 연구에서는 Interval Skip List 자료 구조와 시간기반 윈도우를 이용하여 효율적인 실시간 모니터링 시스템을 구현하였다. 특히 산소포화도 생체 센서들로부터 연속적으로 전송되는 스트림 데이터에 대해 다양한 조건을 포함하는 질의들이 실행 되는데 이러한 실시간 모니터링 질의들을 효율적으로 식별하기 위한 질의 인덱스를 설계하였다.

Mixture Model for Dissolved Oxygen Prediction with Irregular Feeding Events (불규칙성 급이 이벤트에 의한 용존산소량 변화 예측을 위한 혼합 모델 제안)

  • Woo-Jae Kim;Hieyong Jeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.358-360
    • /
    • 2023
  • 뱀장어는 내수면 양식어종으로 뱀장어 양식에서 널리 쓰이는 지수식 양식에 있어서 가장 중요하고 가장 어려운 것은 수질관리다. 수질을 구성하는 요소와 공급된 사료량은 서로 상관관계를 가지며, 이 상관관계에 이상 현상이 발생하면 먹이 섭취 불량과 폐사로 이어질 수 있다. 그래서 본 연구에서는 센서로 측정한 양식장 데이터와 인공지능 모델을 이용하여 수조 속 DO 를 예측하는 모델을 새롭게 제안하여, 적절한 사료 공급 시점과 적절한 공급량을 결정하는 방안에 적절히 사용할 수 있다는 것을 검증하였다. 사료 공급과 공급량에 따른 변화를 가미한 3 시간 후의 DO 를 합당한 이벤트 처리를 통해 예측하였다. 이를 활용하면 사료로 인해 떨어지는 DO 수치를 예측하고, DO 수치가 낮아 회복이 필요한 시점에 투입하는 사료량을 조절하여 질식으로 인해 발생하는 폐사로부터 양식어를 지키며 보다 안정적으로 양식을 위해 활용할 수 있다는 점을 확인할 수 있었다.

Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential (격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.118-128
    • /
    • 1996
  • The lattice parameters of stoichiometric $UO_2$ and $U_{1-y}Er_{y}O_2$ in the range of y=0.01 to y =0.33 were determined with use of X-ray diffraction data. Oxygen potentials have been measured by means of a thermogravimetric method in the range of 1200~$1500^{\circ}C$ and $10^{-14}$ $\leq$ $Po_2$ $\leq$ $10^{-3}$ for pure $UO_2$ and $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions with y=0.02, y=0.06 and y=0.20, respectively. Their oxygen partial pressures were maintained by controlling $CO_2$/CO mixture atmosphere, and the $Po_2$ values corresponding to x of $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions were measured with an electrolyte oxygen sensor. The lattice parameter decreases linearly with an increase in the erbium content. The change of the lattice parameter can be expressed in a linear equation of y as a($\AA$) =5.4695-0.220y for 0 $\leq$y$\leq$0.33. The experimental coefficient of y -0.220 in $U_{1-y}Er_{y}O_2$ was an intermediate value between the calculated values -0.273 and -0.156 in the case of $U^{5+}$ and $U^{6+}$, respectively. The (equation omitted) has been found to undergo abrupt increase in the range of -360 to -270 kJ/mole for y=0.06 and -320 to -220 H/mole for y=0.20, respectively, in the temperature range of 1200-$1500^{\circ}C$. (equation omitted) increases with erbium content, but the effect of the dopant for x =0.01 is less significant than that for stoichiometry. The oxygen potentials for $UO_2$ and $U_{0.98}Er_{0.02}O_{2+x}$ can be approximately represented by the $U^{5+}$/$U^{4+}$ model but those for y$\geq$ 0.06 in $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions cannot be interpreted by the mean uranium valence model.

  • PDF

Development of Capacitive Type Humidity Sensor using Polyimide as Sensing Layer (폴리이미드를 감지층으로 이용한 정전용량형 습도센서 개발)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.366-372
    • /
    • 2019
  • In this paper, we fabricated a capacitive humidity sensor with an IDT(Interdigitated) electrode using commercial polyimide containing fluorine, and its properties were measured and analyzed. First, in order to analyze the composition of commercial polyimide, EDS analysis was performed after patterning process on a silicon wafer. The area of the humidity sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were $3{\mu}m$ each. The number of electrodes was 166 and the length of the electrode was 1.294mm for the sensitivity of the sensor. The fabricated sensor showed that the sensitivity was 24 fF/%RH, linearity <${\pm}2.5%RH$ and hysteresis <${\pm}4%RH$. As a result of measuring the capacitance value according to the frequency change, the capacitance vlaue decreased with increasing frequency. Capacitance deviations with 10kHz and 100kHz were measured as 0.3pF on average.

Assessment of soil moisture-vegetation-carbon flux relationship for agricultural drought using optical multispectral sensor (다중분광광학센서를 활용한 농업가뭄의 토양수분-식생-이산화탄소 플럭스 관계 분석)

  • Sur, Chanyang;Nam, Won-Hob
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.721-728
    • /
    • 2023
  • Agricultural drought is triggered by a depletion of moisture content in the soil, which hinders photosynthesis and thus increases carbon dioxide (CO2) concentrations in the atmosphere. The aim of this study is to analyze the relationship between soil moisture (SM) and vegetation activity toward quantifying CO2 concentration in the atmosphere. To this end, the MODerate resolution imaging spectroradiometer (MODIS), an optical multispectral sensor, was used to evaluate two regions in South Korea for validation. Vegetation activity was analyzed through MOD13A1 vegetation indices products, and MODIS gross primary productivity (GPP) product was used to calculate the CO2 flux based on its relationship with respiration. In the case of SM, it was calculated through the method of applying apparent thermal inertia (ATI) in combination with land surface temperature and albedo. To validate the SM and CO2 flux, flux tower data was used which are the observed measurement values for the extreme drought period of 2014 and 2015 in South Korea. These two variables were analyzed for temporal variation on flux tower data as daily time scale, and the relationship with vegetation index (VI) was synthesized and analyzed on a monthly scale. The highest correlation between SM and VI (correlation coefficient (r) = 0.82) was observed at a time lag of one month, and that between VI and CO2 (r = 0.81) at half month. This regional study suggests a potential capability of MODIS-based SM, VI, and CO2 flux, which can be applied to an assessment of the global view of the agricultural drought by using available satellite remote sensing products.

A Study on the Relationship of Explosion Characteristics and Combustion Heat of Gas Mixtures (가스 혼합물의 폭발압력과 연소열의 상관관계 연구)

  • Oh Khy-hyung;Kim Hong;Yoo Joo-hyun;Kim Tae-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.49-55
    • /
    • 1997
  • Destruction phenomena of structure by gas explosion is due to the explosion pressure and heat. Explosion pressure is a kind of energy converted from the gas mixture explosion. In this paper, we tried to find the relationship between explosion characteristics and combustion heat of the hydrocarbon-oxygen mixtures. Experiment were carried out with the volume of $5916cm^3$ cylindrical explosion vessel. Hydrocarbon gases which used in this study were methane, ethylene, propane, and buthane Experimental parameter was the concentration of the gas mixtures. Explosion characteristics were measured with strain type pressure transducer through the digital storage oscilloscope. From the experimental result, it was found that explosion pressure depend upon the combustion heat.

  • PDF

Effective Water Pollution Management using Reservoir Tank Automatic Classification (저수조 자동 분류를 이용한 효과적인 수질 오염 관리)

  • Chung, Kyung-Yong;Jun, In-Ja
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.1-8
    • /
    • 2009
  • With the development of IT convergence technology and the construction of master plan for the four rivers restoration of the government, the importance of the eco-friendly water pollution management is being spotlighted. In this paper, we proposed the effective water pollution management using the reservoir tank automatic classification for improving the water quality and on-line managing efforts of ceo-friendly reservoir tanks. The proposed method defined the seven factors of water pollution evaluation and managed the water pollution according to hydrogen ion concentration(pH), chemical oxygen demand(COD), suspend solid(SS), dissolved oxygen(DO), count of coliform group(MPN), total phosphorus(T-P), and total nitrogen(T-N) using the sensors. We measured the values for the seven factors from the reservoir tank and normalized to ranging from 1 to 9. To evaluate the performance of the water pollution management using the reservoir tank automatic classification, we conducted F-measure so as to verify usefulness. This evaluation found that the difference of satisfaction by the traditional system was statistically meaningful.

Super-growth of Carbon Nanotubes by O2-assisted Microwave Plasma Chemical Vapor Deposition

  • Park, Sang-Eun;Kim, Yu-Seok;Kim, Seong-Hwan;Lee, Su-Il;Jo, Ju-Mi;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.387-387
    • /
    • 2011
  • 탄소 나노튜브(Carbon nanotubes, CNTs)는 육각형 모양의 구조로서 오직 탄소만으로 이루어진 소재이다. CNT는 열전도율이 다이아몬드보다 약 2배 우수하고, 전기 전도는 구리에 비해 1,000배 높으며, 강도는 강철보다 100배나 뛰어나다. CNT의 이러한 특성을 이용한 트랜지스터, 태양전지, 가스 검출을 위한 고감도 센서, 나노 섬유, 고분자-탄소나노튜브 고기능 복합체 등 많은 분야에서 연구가 활발히 진행되고 있다. 또한 수직으로 성장된 탄소 나노튜브는 일반적인 재료에서는 보기 드물게 힘들게 직경이 나노 크기인 반면 길이는 수 mm까지 합성 되기 때문에 앞서 언급한 분야로의 활용이 더욱 유리하며, 그 중에서도 나노 섬유, 나노 복합체로서의 활용에 극히 유용하다. 이러한 이유로 수직 배열된 CNT 합성에 많은 연구가 집중 되고 있다. 여러 합성 방법 중 성장 변수를 비교적 용이하게 조절 가능한 열 화학 기상 증착법(Thermal chemical vapor deposition, TCVD)을 이용하여 수직 배열된 수 mm의 CNT를 합성한 연구 결과들이 보고된 바 있다. 그러나 앞선 연구결과들은 CNT의 성장속도가 느릴 뿐만 아니라 합성 시간이 길어질수록 성장 속도가 감소하는 경향을 보였다. 반면, 마이크로웨이브 플라즈마 화학 기상 증착법(Microwave plasma CVD, MPCVD)은 기존의 다른 TCVD에 비해 낮은 온도에서 CNT를 합성할 수 있는 장점을 가지며, 고출력(~600 W 이상)의 플라즈마를 사용하기 때문에 성장률이 높고 고밀도의 CNT 합성이 가능하다. 본 연구에서는 철을 촉매금속으로 사용하고 MPCVD을 이용하여 얇은 다중벽 CNT를 합성하였다. 철은 직류 마그네트론 스퍼터(D.C magnetron sputter)를 사용하여 증착하였다. 합성시 가스는 탄소 공급원인 메탄($CH_4$)과 함께 플라즈마 공급원인 수소($H_2$)를 사용하였다. 또한 산소($O_2$)의 주입 여부에 따른 CNT의 성장 속도와 성장 길이를 비교하였다. 산소를 주입하였을 때, CNT의 성장 속도와 길이 모두 크게 향상됨을 확인 할 수 있었다. 이는 촉매금속 표면의 비정질 탄소의 흡착으로 인해 활성화된 촉매금속의 반응시간을 증가시키기 때문이다. 성장된 CNT는 주사전자 현미경(Scanning Electron Microscopy, SEM)과 라만 분광법(Raman spectroscopy)을 통해 표면형상과 결정성을 분석하였다.

  • PDF