• Title/Summary/Keyword: 산소공여입자

Search Result 23, Processing Time 0.025 seconds

Reaction Characteristics of Oxygen Carrier Perticle for Chemical-Looping Combustor in Fixed Bed and Pressurized Fluidized Bed (고정층과 가압유동층에서 매체순환식 가스연소기 산소공여입자의 반응특성)

  • 류호정;배달희;진경태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.173-177
    • /
    • 2002
  • 두 개의 유동층 사이를 순환하는 금속매체(Metal or Metal oxide)를 이용하여 공기에 의한 금속매체의 산화와 기체연료(H$_2$, CO, CH$_4$등)에 의한 금속산화물의 환원반응이 별개의 반응기에서 일어나게 하는 새로운 개념의 연소기술인 매체순환식 가스연소기술은 공기와 기체연료를 직접 접촉시켜 반응하는 기존의 가스연소기에 비해 많은 장점을 가지고 있다.(중략)

  • PDF

Characteristics of Carbon Deposition and Cyclic Test of Oxygen Carrier Particle for Chemical-Looping Combustor (매체순환식 가스연소기 산소공여입자의 탄소침적 및 반복실험 특성)

  • 김민수;임남윤;류호정;배달희;진경태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.79-83
    • /
    • 2002
  • 새로운 가스연소 개념인 매체순환식 가스연소기(Chemical-Looping Combustor, CLC)는 공기와 기체연료(H$_2$, CO, CH$_4$ 등)가 직접 접촉하여 연소하는 기존의 연소-발전 시스템에 비해 많은 장점들을 가지고 있다. 매체순환식 가스연소기의 기본개념은 Fig. 1에 나타내었다.(중략)

  • PDF

Comparison of Reactivity of Oxygen Carrier Particles by TGA (TGA를 이용한 매체순환식 가스연소기 산소공여입자의 반응성 비교)

  • 임남윤;류호정;진경태;배성렬
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.621-625
    • /
    • 2003
  • 최근 지구온난화 문제와 관련하여 국제적으로 이슈가 되고 있는 $CO_2$ 저감 및 처리기술 중에서 연소 후 처리가 아닌 신개념 연소기술로서 NO$_{x}$가 배출되지 않고 $CO_2$의 고농도 원천분리가 가능하여 새로운 연소 및 발전기술로 부상하고 있는 매체순환식 가스연소기술(Chemical-Looping Combustion Technology, CLC)에 대한 연구가 국내외적으로 활발하게 진행되고 있다.(중략)

  • PDF

Conceptual Design of 50 kW thermal Chemical-Looping Combustor and Analysis of Variables (열량기준 50kW급 매체순환식 가스연소기의 개념설계 및 변수해석)

  • 류호정;진경태
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.289-301
    • /
    • 2003
  • To develop a chemical-looping combustion technology, conceptual design of 50 kW thermal chemical-looping combustor, which is composed of two interconnected pressurized circulating fluidized beds, was performed by means of mass and energy balance calculations. A riser type fast fluidized bed was selected as an oxidizer and a bubbling fluidized bed was selected as a reducer by mass balance for the chemical-looping combustor. Calculated values of bed mass, solid circulation flux, and reactor dimension by mass and energy balance calculations were suitable for construction and operation of chemical-looping combustor. It is concluded from the comparison of the design results and operating values of commercial circulating fluidized bed that the process outline is realistic. Moreover, the previous results support that oxygen carrier particle, NiO/bentonite, fulfills the conversion rates needed for the proposed design. The effects of system capacity, metal oxide content in a oxygen carrier particle, amount of steam input, gas velocity, and solid depth on design values were investigated and the changes in the system performance can be estimated by proposed design tool.

Direct Combustion Characteristics of Coal by Oxygen Carrier (산소공여입자에 의한 석탄의 직접연소 특성)

  • Ryu, Hojung;Lee, Chungwon;Lee, Dongho;Bae, Dalhee;Lee, Suengyong;Park, Yeongseong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.87-96
    • /
    • 2014
  • Direct combustion characteristics of coal and oxygen carrier were measured in the thermogravimetric analyzer using four coals and two different oxygen carriers. The direct combustion efficiency decreased in order of Roto, Kideco, Sunhwa and Hyper coal for both oxygen carriers. Moreover, OCN703-1100 oxygen carrier showed better combustion efficiency than OCN706-1100 oxygen carrier for all four coals. The reduction characteristics of two oxygen carriers for $CH_4$, CO and $H_2$ gases were measured in the thermogravimetric analyzer to investigate why OCN703-1100 oxygen carrier showed better combustion efficiency than OCN706-1100 for all coals. The OCN703-1100 oxygen carrier represented higher reduction rate than OCN706-1100 for all reducing gases. Moreover, the total pore area and the porosity of OCN703-1100 were higher than those of OCN706-1100 oxygen carrier. The total volatile gas and volatile components of four coals were measured in a batch type fluidized bed reactor to investigate why the direct combustion efficiency decreased in order of Roto, Kideco, Sunhwa and Hyper coal for both oxygen carriers. The direct combustion efficiency was proportional to the total amount of ($CH_4+CO+H_2$) produced during devolatilization of coals.

Reaction Characteristics of Five Kinds of Oxygen Carrier Particles for Chemical-Looping Combustor (매체순환식 가스연소기 적용을 위한 5가지 산소공여입자들의 반응특성)

  • Ryu, Ho-Jung;Kim, Gyoung-Tae;Lim, Nam-Yun;Bae, Seong-Youl
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.24-34
    • /
    • 2003
  • For gaseous fuel combustion with inherent $CO_2$ capture and low NOx emission, chemical-looping combustion may yield great advantages for the savings of energy to $CO_2$ separation and suppressing the effect on environment, In chemical-looping combustor, fuel is oxidized by metal oxide medium in a reduction reactor. Reduced particles are transported to oxidation reactor and oxidized by air and recycled to reduction reactor. The fuel and the air are never mixed, and the gases from reduction reactor, $CO_2$ and $H_2O$, leave the system as separate stream. The $H_2O$ can be easily separated by condensation and pure $CO_2$ is obtained without any loss of energy for separation. In this study, five oxygen carrier particles such as NiO/bentonite, NiO/YSZ, $(NiO+Fe_2O_3)VYSZ$, $NiO/NiAl_2O_4$, and $Co_{\chi}O_y/CoAl_2O_4$ were examined &om the viewpoints of reaction kinetics, oxygen transfer capacity, and carbon deposition characteristics. Among five oxygen particles, NiO/YSZ particle is superior in reaction rate, oxygen carrier capacity, and carbon deposition to other particles. However, at high temperature ($>900^{\circ}C$), NiO/bentonite particle also shows enough reactivity and oxygen carrier capacity to be applied in a practical system.

Reduction Characteristics of Mass Produced Particle for Chemical-Looping Combustor with Different Fuels (매체순환식 가스연소기용 대량생산입자의 연료별 환원반응특성)

  • Ryu, Ho-Jung;Kim, Kyung-Su;Lee, Seung-Yong;Park, Yeong-Seong;Park, Moon-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.348-358
    • /
    • 2008
  • Reduction reactivity and carbon deposition characteristics of mass produced oxygen carrier particle(OCN-650) have been investigated by using hydrogen, methane, syngas, and natural gas as fuels. For all fuels, the maximum conversion and oxygen transfer capacity increased as the temperature increase. The reduction rate and the oxygen transfer rate increased as the temperature increase for methane. However, those values showed maximum at 900$^{\circ}C$ for hydrogen, syngas, and natural gas. To explain consistently the change of maximum conversion, reduction rate, oxygen transfer capacity, oxygen transfer rate and degree of carbon deposition for different fuels, new parameters such as reactive carbon contents and require oxygen per input gas were adopted.

Performance Estimation and Process Selection for Chemical-Looping Hydrogen Generation System (금속매체 순환식 수소생산 시스템의 성능예측 및 공정선정)

  • Ryu, Ho-Jung;Jin, Gyoung-Tae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.3
    • /
    • pp.209-218
    • /
    • 2005
  • To find a suitable metal component in oxygen carrier particles for chemical-looping hydrogen generation system(CLH), oxygen transfer capacities of metal components were compared and Ni has been selected as the best metal component. The proper operating conditions to achieve high hydrogen generation rate have been investigated based on the chemical-equilibrium composition analysis for water splitting reactor. Moreover, suitable compositions of syngas from gasifier of heavy residue to achieve high energy efficiency have been investigated by calculation of heat of reaction. Based on the selected operating conditions, the best configuration of two interconnected fluidized beds system for the chemical-looping hydrogen generator has been investigated as well.

LNG Combustion Characteristics of Oxygen Carrier Particles for Chemical-Looping Combustor (매체순환식 가스연소기 산소공여입자의 LNG 연소특성)

  • Ryu, Ho-Jung;Bae, Dal-Hee;Jin, Gyoung-Tae
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.141-147
    • /
    • 2005
  • LNG combustion characteristics of oxygen carrier particles were investigated in a batch type bubbling fluidized bed reactor. Three particles, NiO/bentonite, $NiO/NiAl_2O_4$, $CO_xO_y/CoAl_2O_4$, were used as oxygen carrier particles and LNG and air were used as reactants for reduction and oxidation, respectively. In the reducer, high gas conversion and high $CO_2$ selectivity were achieved for all three particles. In the oxidizer, NOx was not detected. The results of exhaust gas analysis showed that inherent $CO_2$ separation and NOx-free combustion are possible in the LNG fueled chemical-looping combustion system with NiO/bentonite, $NiO/NiAl_2O_4$ and $Ca_xO_y/CoAl_2O_4$ particles.

  • PDF