• Title/Summary/Keyword: 산란유형

Search Result 35, Processing Time 0.028 seconds

The Comparison of Quantitative Accuracy Between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2015
  • Purpose In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. Thus, a wide range of scatter correction(SC) methods have been studied and this study is to evaluate the accuracy of CT based SC(CTSC) used in SPECT/CT as the comparison with existing energy window based SC(EWSC). Materials and Methods SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. In both conditions, Astonish(iterative : 4 subset : 16) reconstruction method and CT attenuation correction were commonly applied and three types of SC methods such as non-scatter correction(NSC), EWSC, CTSC were used in images filled with image. For EWSC, 9 sub-energy windows were set additionally in addition to main(=peak) energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Results Based on the image filled with air, %SF of images filled with water to which each SC method was applied is NSC 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the most scattering counts were removed in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. Conclusion In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

  • PDF

A study on electron beam lithography for 0.1$\mu\textrm{M}$ T-gate formation at P(MMA/MAA)/PMMA structure (PMMA/P(MMA/MAA) 구조에서 0.1$\mu\textrm{M}$ T-gate 형성을 위한 전자빔 리소그래피 공정에 관한 연구)

  • Choe, Sang-Su;Lee, Jin-Hui;Yu, Hyeong-Jun;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.96-103
    • /
    • 1995
  • This art~cle reports on the formation of T - Gate with O.1$\mu$m foot and 0.4$\mu$m head width at PMMA/P( MMA/MAA) resist structure using a 30KV electron beam lithography system. From the result of Monte Carlo simulation on PMMA/P( MMA/MAA)/GaAs, we obtain the dissipation energy ratio of forwardscattered electron and backscattered electron within 0.1$\mu$m scattering radius is 19.5 : 1 0.1$\mu$m T - gate has been formed with 30KV gaussian electron beam at a 440$\mu C/\textrm{cm}^2$ dosage. The gamma value of PMMA and P(MMA/MAA) at MIBK : IPA=l : 1 developer was 2.3. The overlay accuracy(3$\sigma$) from mix-andmatch of optical stepper and Ekeam lithography system for fabricating HEMT device is accomplished below 0.1$\mu$m.

  • PDF

Characteristics of Vocalizations of Laying Hen Related with Space in Battery Cage (케이지 내 사육 공간의 차이에 따른 산란계의 음성 특성)

  • Son, Seung-Hun;Shin, Ji-Hye;Kim, Min-Jin;Kang, Jeong-Hoon;Rhim, Shin-Jae;Paik, In-Kee
    • Journal of Animal Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.421-426
    • /
    • 2009
  • This study was conducted to clarify the characteristics of vocalization of laying hen related with space in battery cage. The size of cages were classified into control (0.30 m ${\times}$ 0.14 m ${\times}$ 0.55 m, length ${\times}$ width ${\times}$ height), small (0.21 m ${\times}$ 0.14 m ${\times}$ 0.55 m) and large (0.30 m ${\times}$ 0.30 m ${\times}$ 0.55 m) size. Vocalization of 16 individuals of laying hen in each group of Hy-Line Brown (80 week old) were recorded 3 hours per day (10:00am~11:00am, 3:00pm~4:00pm and 7:00pm~8:00pm) using digital recorder and microphone during October 2008 and February 2009. Characteristics of frequency, intensity and duration of vocalization were analyzed by GLM (general linear model) and Duncan's multi-test. There were differences in basic and maximum frequency, and intensity based on analysis of spectrogram and spectrum among different cage sizes. Vocalization of laying hen would be one of the indicators to understand the stress caused by rearing space in batter cage.

A study on the development of instream habitat creation technique (하도 내 생물서식처 조성기술개발에 관한 연구)

  • Kim, Si-Nae;Lee, Dong-Jun;Ahn, Hong-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.117-121
    • /
    • 2011
  • 기존 국내의 자연형 하천복원사업은 인위적으로 정비된 하천을 대상으로 훼손된 자연성을 되살리기 위하여 물리적 환경의 개선을 중심으로 진행되었으며, 저수호안의 안정성과 더불어 식생 피복율을 높이는 등 형태적 복원을 중심으로 사업이 시행되어 왔다. 이러한 자연형 하천복원사업은 하천의 생태적 특성에 대한 고려가 미비하여 하천이 생물서식처로서의 기능을 수행하는 데에는 효과적이지 못하였다. 따라서 본 연구는 하천의 물리적 특성에 의하여 형성되는 생물서식처와 이에 반응하는 생물들의 상호관련성을 분석하여 생물들에게 적합한 서식환경을 제공할 수 있는 기술을 개발하며, 하천유역의 환경 훼손으로 인하여 개체수가 급감하고 있는 종을 복원 목표종으로 선정하여 개발된 기술을 현장에 시범적으로 적용하여 기술을 검증함으로써 생물을 중심으로 한 자연과 함께하는 하천복원기술을 개발하고자 하였다. 이를 위해 우리나라의 중소하천을 대표할 수 있는 대표하천을 선정하여, 서식처 유형을 분류하고 각 서식처의 물리 화학 생태특성을 분석하였으며, 이를 통해 납자루아과 어종의 산란처 및 서식처로서의 역할을 하는 개방형 하도습지 조성 기술을 개발 및 시범적용 하였다.

  • PDF

The KALION Automated Aerosol Type Classification and Mass Concentration Calculation Algorithm (한반도 에어로졸 라이다 네트워크(KALION)의 에어로졸 유형 구분 및 질량 농도 산출 알고리즘)

  • Yeo, Huidong;Kim, Sang-Woo;Lee, Chulkyu;Kim, Dukhyeon;Kim, Byung-Gon;Kim, Sewon;Nam, Hyoung-Gu;Noh, Young Min;Park, Soojin;Park, Chan Bong;Seo, Kwangsuk;Choi, Jin-Young;Lee, Myong-In;Lee, Eun hye
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.2
    • /
    • pp.119-131
    • /
    • 2016
  • Descriptions are provided of the automated aerosol-type classification and mass concentration calculation algorithm for real-time data processing and aerosol products in Korea Aerosol Lidar Observation Network (KALION, http://www.kalion.kr). The KALION algorithm provides aerosol-cloud classification and three aerosol types (clean continental, dust, and polluted continental/urban pollution aerosols). It also generates vertically resolved distributions of aerosol extinction coefficient and mass concentration. An extinction-to-backscatter ratio (lidar ratio) of 63.31 sr and aerosol mass extinction efficiency of $3.36m^2g^{-1}$ ($1.39m^2g^{-1}$ for dust), determined from co-located sky radiometer and $PM_{10}$ mass concentration measurements in Seoul from June 2006 to December 2015, are deployed in the algorithm. To assess the robustness of the algorithm, we investigate the pollution and dust events in Seoul on 28-30 March, 2015. The aerosol-type identification, especially for dust particles, is agreed with the official Asian dust report by Korean Meteorological Administration. The lidar-derived mass concentrations also well match with $PM_{10}$ mass concentrations. Mean bias difference between $PM_{10}$ and lidar-derived mass concentrations estimated from June 2006 to December 2015 in Seoul is about $3{\mu}g\;m^{-3}$. Lidar ratio and aerosol mass extinction efficiency for each aerosol types will be developed and implemented into the KALION algorithm. More products, such as ice and water-droplet cloud discrimination, cloud base height, and boundary layer height will be produced by the KALION algorithm.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Random heterogeneous model with bimodal velocity distribution for Methane Hydrate exploration (바이모달 분포형태 랜덤 불균질 매질에 의한 메탄하이드레이트층 모델화)

  • Kamei Rie;Hato Masami;Matsuoka Toshifumi
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.41-49
    • /
    • 2005
  • We have developed a random heterogeneous velocity model with bimodal distribution in methane hydrate-bearing Bones. The P-wave well-log data have a von Karman type autocorrelation function and non-Gaussian distribution. The velocity histogram has two peaks separated by several hundred metres per second. A random heterogeneous medium with bimodal distribution is generated by mapping of a medium with a Gaussian probability distribution, yielded by the normal spectral-based generation method. By using an ellipsoidal autocorrelation function, the random medium also incorporates anisotropy of autocorrelation lengths. A simulated P-wave velocity log reproduces well the features of the field data. This model is applied to two simulations of elastic wane propagation. Synthetic reflection sections with source signals in two different frequency bands imply that the velocity fluctuation of the random model with bimodal distribution causes the frequency dependence of the Bottom Simulating Reflector (BSR) by affecting wave field scattering. A synthetic cross-well section suggests that the strong attenuation observed in field data might be caused by the extrinsic attenuation in scattering. We conclude that random heterogeneity with bimodal distribution is a key issue in modelling hydrate-bearing Bones, and that it can explain the frequency dependence and scattering observed in seismic sections in such areas.

Evaluation of the Usefulness of Tungsten Nanoparticles as an Alternative to Lead Shielding Materials in Electron Beam Therapy (전자선 치료시 납 차폐체 대체물질로서의 텅스텐 나노입자의 유용성 평가)

  • Kim, Ji-Hyang;Kim, Na-Kyoung;Lee, Gyu-Yeong;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.949-956
    • /
    • 2021
  • The purpose of this paper is to evaluate whether tungsten nanoparticles have a shielding effect on scattered light generated at high doses as an alternative material to lead used to shield scattered light in electron beam therapy. A plate was manufactured to set the position of the dosimeter and the size of the radiation field to be constant. The glass dosimeter was placed at 12 points, which were 1, 2, and 4 cm apart from the center of the field of 10 × 10 cm2 in the cross direction. A total of 12 types of tungsten nanoparticle shields were developed with a thickness of 0.75 mm to 4.00 mm and a size of 10 × 10 cm2 using 0.4, 0.75, and 1 mm materials. Using a linear accelerator, measurements were made four times at 6 MeV and four times at 12 MeV, and the dose intensity was investigated at 100 MU. The 4 mm shielding plate showed the highest shielding effect at 1 cm from the irradiation field. The 1 mm shielding plate at 2 cm from the irradiation field had the lowest shielding effect. As the thickness of the tungsten shielding plate increased, the electron beam's shielding effect increased sharply. It was confirmed that tungsten nanoparticles can reduce the amount of scattered light generated by electron beam therapy. Therefore, this study will provide basic data when follow-up studies are conducted on the shielding ability of tungsten nanoparticles.

An Assessment of Utilization of the Pungchon Limestone in Paper Industry (풍촌층 석회석의 제지 산업에서의 응용성 평가)

  • Lee, Na-Kyong;Noh, Jin-Hwan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.339-349
    • /
    • 2007
  • For various types of the Pungchon limestone, diverse mineral characters of the limestone including their size and morphology are investigated by using of ELS and SEM to examine the possibility of application as fillers to paper industry. Also, the measurement of zeta potential and the evaluation of coagulation properties in calcite suspension was made for fine powders of the limestone to examine the applicability and efficiency in wet-papermaking process. Fine powder of the Pungchon lime-stone, largely controlled by original mineral characters of ore in mineralogical aspects, exhibits some-what different trend in particle morphology according to ore types, and thereby, the size distribution, zeta potential and coagulation properties also become different. The examined whiteness, brightness, opacity and sheet strength in hand sheet also show remarkable differences according to ore types. These are seemed to be basically due to the results of combined effects of whiteness, site distribution, refractive index, and morphology of the limestone powder on the properties of hand sheet. Considering the investigated results, all types of the Pungchon limestone appear to be sufficiently applicable to paper industry. Especially, the mega-crystalline calcite type is evaluated to be overall suitable for the purpose of paper industry due to the higher values in whiteness and brightness. In addition the fine powder of micro-crystalline calcite type is assessed particularly to have a good quality in sheet strength by virtue of irregular particle shape.

Desulfurization efficiency in photobioreactors dependent on the irradiation type of light sources (광생물반응기내 광조사 유형별 탈황 효율)

  • An, Jin Young;Kim, Byung Woo
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.71-78
    • /
    • 2000
  • Removal rates of hydrogen sulfide were investigated to known effects of several light sources with external and internal irradiation on the desulfurization using C. thiosulfatophilum. In the case of internal illumination system, optical-fiber photobioreactor was applied to increase the light availability. Furthermore, sunlight was used as the main light energy in the daytime and metal-halide lamp was applied as an additional light energy at night. Light energy of 99% was saved by the application of the LED's array in comparison with the incandescent light source. $H_2S$ removal rates at 5,000 lux in a 4-L photobioreactor were shown as 0.040, 0.138, 0.136, and 0.134 (${\mu}mol$ $H_2S/min$)/(mg protein/L), respectively, in the following order of light sources, when several light sources such as fluorescent, energy-saving, incandescent, halogen lamp, and filtered light at 460 nm were applied. Removal rate per unit cell concentration with the internal light diffused optical-fibers increased about 1 six times as much as that with the external light sources. Removal rate per unit cell concentration, using sunlight in the daytime and a metal-halide lamp at night, was 0.41 less than 0.869 (${\mu}mol$ $H_2S/min$)/(mg protein/L) using a 400 W metal-halide lamp day and night, since the automatic sunlight collection system can transmit the light intensity as only 10% of that with a metal-halide lamp.

  • PDF