• Title/Summary/Keyword: 산란선 함유율

Search Result 6, Processing Time 0.022 seconds

Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus (X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향)

  • Lee, Hoo-Min;Yoon, Joon;Kim, Hyun-Ju
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.187-193
    • /
    • 2014
  • The purpose of this study was to analyze the effect on the selectivity on of high-voltage rectification device that measured the performance of the grid, and the contrast improvement ability (K factor) by measuring the scattered radiation content of the transmitted X-rays. The scattered radiation generated when the X-ray flux comes from the diagnostic X-ray generator that passes through an object. Targeting four different rectifications of X-ray generators, the mean value of the tube voltage and the tube current was measured in order to maximize the accuracy of the generating power dose within the same exposure condition. Using fluorescence meter, the content of the scattered rays that are transmitted through the acrylic was measured depending on the grid usage. When grid is not used, the content of the scattered rays was the lowest (34.158%) with the single-phase rectifier, was increased with the inverter rectifier (37.043%) and the three-phase 24-peak rectification method (37.447%). The difference of the scattered radiation content of each device was significant from the lowest 0.404% to the highest 3.289% while using 8:1 grid, the content of the scattered ray was the lowest with the single content of the scattered ray was the lowest with the single-phase rectifier (18.258%), was increased with the rectifier (25.502%) and the 24-peaks rectification (24.217%). Furthermore, there was difference up to content 7.244% to the lowest content 1.285% within three-phase 24-peaks rectification, inverter rectifications, and single-phase rectifier depending on the selectivity of the grid. Drawn from the statistical analysis, there was a similar relationship between the contrast improvement factor and the K factor. As a result, the grid selectivity and the contrast were increased within the single-phase rectifier rather than the constant voltage rectifier.

품질 인증 등록, 흑운모 · 녹차유정란 생산현장

  • Jang, Seong-Yeong
    • KOREAN POULTRY JOURNAL
    • /
    • v.38 no.6 s.440
    • /
    • pp.120-123
    • /
    • 2006
  • 선모자연농원(대표 양승덕)은 지난 2006년 3월 10일 우리 시대에 맞는 친환경 생산물을 이용해 무항생제, 항산화제로 소비자에게 깨끗하고 신선한 계란을 공급하고자 3년간의 지속적인 연구 끝에 흑운모와 녹차를 함유한 유정란의 품질인증을 받았고, 현재 특허등록을 위해 출원한 상태이다.(출원번호 40-2006-0012500). 양승덕 사장은 흑운모가 황토와 맥반석보다 약 3배 이상 원적외선 방사율(94%)이 높으며 게르마늄 함유량이 36ppm에 이르는 생명의 돌로서 예전부터 흑운모석을 약돌이라 부른 것에 착안하여 산란계에도 흑운모 분말을 배합한 사료를 급여하였다. 본고는 웰빙시대에 걸 맞는 흑운모, 녹차의 기능과 이를 이용해 국내에서 어렵게 생산한 "흑운모 · 녹차유정란"의 특성을 살려 생산하는 현장을 취재하였다.

  • PDF

A Study on the Scattered-ray Content in Transmitted-ray (산란선함유율(散亂線含有率)에 관(關)한 연구(硏究))

  • Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.81-84
    • /
    • 1983
  • Scattered-rays are produced from objects in x-ray diagnosis and the quality of x-ray image is influenced by presence of the scattered-ray. Therefore, constant ways and means to suppress and to eliminate the scattered-ray were devised. Authors made an experimental study on the scattered-ray content in transmitted-ray using acryl phantoms and obtained the results as follows: 1. The scattered-ray content in transmitted-ray is not influenced by filtration and tube voltage. 2. Irradiated field size and the thickness of object are a potent influence to scattered-ray content.

  • PDF

An Experiment on Scattered-ray Content Ratio and Skin Dose according to the Exposure Condition for Chest Radiography (흉부 X선촬영조건의 변화에 따른 산란선 함유율과 피부선량에 관한 연구)

  • Park, Young-Sun;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.3-9
    • /
    • 1992
  • In an experiment using chest radiography, the authors measured the scattered ray content ratio and exposed skin dose giving varieties to the object thickness, tube voltage, additional filters and gird. The result was as follows, In the 80 kV the required mAs for the density 1.8 was $10{\sim}20$ times as much as in the 140 kV, and when 10 : 1 grid was used the required mAs was $3{\sim}5$ times as much as when grid was not used. Under the same tube voltage the scattered ray content ratios were increased as the additional filter thickness became thicker. And when 10 : 1 grid was used the ratio could be decreased $2{\sim}5$ times as much as when grid was not used. Skin doses exposed to the patients were increasing as the thickness of the object became thicker, and were decreasing as filters became thicker while showing slow the decreasing effects above the 1/8 VL. And when the grid was used skin doses were increased $2{\sim}4$ times as much as when not used. In order to improve the image qualities while reducing the exposures in the chest radiography, the authors suggest followings. The additional filters up to the 1/2 VL will be suitable according to the thickness of the objects in the 80kv, while the 10 : 1 grid and additional filter of 1/8 VL will be suitable in the 140 kV.

  • PDF

The Seasonal Variations of the Oil Content and Vitamin A Distribution of Mackerel Caught in Korea (한국산(韓國産) 고등어의 Vitamin A 분포(分布) 및 시기적변화(時期的變化)에 대하여)

  • Lee, Eung-Ho
    • Applied Biological Chemistry
    • /
    • v.6
    • /
    • pp.15-24
    • /
    • 1965
  • The mackerels, Scomber japonicus (HOUTTYN), for this study were caught by purse sein net in Korea. In this paper, the seasonal variations of the oil content and Vitamin A concentration in oil in different parts of the mackerel, the distribution of the Vitamin A of viscera of that and physical and chemical constants of oil were discussed. The results are summarized as follows: 1. In the beginning of June, the liver weight increased rapidly and reached the maximum. In this period, the gonad weight was also maximum. It seemed that this phenomenon has influenced on the nutritional and physiological aspects of the spawning stage. 2. The Vitamin A concentration of liver oil reached the maximum value in the middle of July. In the most case, it was proportinate to the oil content in liver inversely. 3. The Vitamin A concentration of pyloric caeca oil reached the maximum Value in the late of July. It showed the tendency of being proportionate to the oil content in pyloric caeca inversely. And the Vitamin A concentration of intestine oil reached maximum value in the beginning of July. 4. The distribution average ratio of Vitamin A in liver, pyloric caeca, intestine, stomach and contents of stomach and gonad to the total Vitamin A in whole viscera were 60.8, 29.4, 5.7, 2.2, and 1.9 percentage. The seasonal variation of the distribution of Vitamin A in pyloric caeca to the amount of total Vitamin A in whole viscera was proportionate to that of liver inversely. 5. It seemed that there were no any corelation between the Vitamin A content and seasonal variation of the physical and chemical constants of viscera oil. But when the Vitamin A concentration was high, the refractive index, the amount of unsaponifiable matter and iodine value of viscera oil were also high. 6. On the extracting vitamin oil of viscera of mackerel, it is the most suitable period from the end of May to the middle of October. The liver, pyloric caeca and intestine of mackerel are valuable and the other parts of vicera are worthless as vitamin oil resources. It is probable that the whole viscera oil could also be utilized as vitamin-rich oil, if it were concentrated.

  • PDF

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber (국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.564-567
    • /
    • 2012
  • Optical fibers are going to be used for telecommunication, image fibers, sensors under irradiation in nuclear power plants and various irradiation facilities. Especially, Temperature detection sensors using Raman light scattering, temperature or strain sensors using fiber gratings, magnet-optical sensors using photo-magnetic effect, are already commercialized. However, When fibers are exposed to ionizing radiation, color centers are formed in fibers which reduces their light transmission, and it is limited in applying under radiation environments. In this study, $Co^{60}$ gamma-ray induced optical attenuation on Ge-doped single mode(SM) fiber has been measured. Gamma-ray is irradiated for 4hours at the dose rate of 0.5kGy/hr, 2kGy/hr, 8kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur precisely. Furthermore, dose rate effect that the higher dose rate in the same total dose, the more increase loss of optical fiber and annealing effect that the higher the loss after irradiation, the more increase the recovery rate of the loss are observed in the fiber. This results plan to make use of bases in the study of the radiation-hardened optical fiber.

  • PDF