• Title/Summary/Keyword: 삭제방법

Search Result 637, Processing Time 0.033 seconds

A Collision Model for Haptic Simulation of Tooth Preparation (치아 형성의 햅틱 시뮬레이션을 위한 충돌 모델)

  • Kim, Ki-Min;Kim, Jai-Hyun;Park, Jin-Ah
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06a
    • /
    • pp.438-441
    • /
    • 2011
  • 가상현실기반 충치치료 훈련 시스템에서 필수적으로 구현되어야 하는 부문은 절삭도구인 버(bur)를 이용하여 치아를 삭제하는 과정이다. 치아에 비하여 시술도구의 크기가 상대적으로 매우 작기 때문에 보다 정교한 충돌감지뿐만 아니라 치아 삭제에 따른 형태변형에 동기화된 정확한 충돌 모델이 요구된다. 따라서 본 논문에서는 디스턴스 필드를 이용한 볼륨 모델을 치아에 적용하고 이를 형태변형 시각화와 햅틱 렌더링에 함께 이용하는 실시간 충돌 모델을 제안한다. 또한 안정적인 햅틱 피드백을 위해 버의 포인트 쉘 생성 방법과 시간 응집도에 따른 점 접촉 모델 가속화 방법을 제시한다.

Analysis of Axial Splitting of Circular Metal Tubes by Using Element Deletion Method (요소 삭제 방법을 사용한 원형 금속 관의 축방향 파단 해석)

  • Lee, Sang-Hoon;Kim, Hyun-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.6
    • /
    • pp.496-503
    • /
    • 2008
  • With the improvement of computer power and technology, fracture modelling by finite element methods has become a topic of extensive studies. However, fracture simulation much limited to an academic study of crack propagation with a fine mesh. Element deletion method is a useful tool for estimating damage due to accidental or extreme loads on structures, provided that an effective and realistic criterion is established for simulating the material failure and subsequent element deletion. In this study, ABAQUS/Explicit is used to simulate the material failure on the basis of experimental results by X. Huang et al. Through numerical experiments, we suggest a formulation to determine the failure strain associated with the size and thickness of removed elements.

Adaptive Rule Estimation (ARE) Algorithm against Eluding NIDS (적응적 규칙 추정에 의한 네트워크기반 침입탐지시스템 우회공격 방지 기법)

  • Choi, Byeongl-Cheol;Seo, Dong-Il;Sohn, Sung-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11b
    • /
    • pp.975-978
    • /
    • 2002
  • 본 연구는 네트워크 기반 침입탐지 시스템(NIDS)의 우회공격 방지를 위한 적응적 규칙 추정 알고리즘(ARE; Adaptive Rule Estimation)을 제안한다. 네트워크 기반 침입탐지 시스템에서 가장 많이 사용하는 침입탐지 방법은 규칙 기반의 패턴 매칭 기법이며, 이 방법은 삽입과 삭제에 의한 우회 공격에 많은 취약성을 가지고 있다. 본 연구에서는 이러한 삽입과 삭제에 의한 우회 공격을 방지 하고자 하는 취지에서 제안된 알고리즘이다. 적응적 규칙 추정에 의한 침입 탐지 알고리즘은 두 개의 과정으로 구성되며, 전처리 부분에서는 최적의 규칙을 선택하고, 주처리 부분에서 적응적으로 규칙 패턴의 변형된 위치를 찾아서 비교 판단하는 과정으로 이루어져 있다. 제안된 적응적 규칙 추정 알고리즘은 기존의 규칙 기반 패턴 매칭에서 우회공격이 가능한 것들이 탐지되며, 미탐지 확률을 줄일 수 있다.

  • PDF

A Study on Data Classification for Digital Forensic in IoT (IoT 환경에서의 디지털 포렌식을 위한 데이터 분류 방법에 관한 연구)

  • Ryu, Ho-Seok;Kawk, Jin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.705-707
    • /
    • 2015
  • 정보통신기술의 발달로 무선 네트워크 기능이 스마트 디바이스에 삽입됨에 따라 IoT 서비스는 다양해지고 있다. IoT 환경에서의 스마트 디바이스들은 사용자의 ID와 계정을 통해 동기화하기 때문에 연동된 디바이스를 통해 사용자에게 다양한 서비스를 제공하고 있다. 연동된 디바이스에는 개인 정보, 위치 정보 등 다양하고 방대한 양의 데이터가 저장되어 있다. 이러한 데이터들은 연동 디바이스를 통해 데이터의 변경, 수정, 삭제가 가능해졌다. 따라서 용의자가 동기화된 데이터를 변경, 수정, 삭제 한다면 법적 증거 효력이 사라질 수 있다. 또한, IoT 환경에는 방대한 양의 데이터가 존재하기 때문에 데이터 분류에 어려움이 따른다. 따라서 본 논문에서는 디지털 포렌식을 위한 IoT 환경에서의 데이터 분류 방법을 제안 한다.

2D Inundation Analysis of SWMM Model according to Sewer Network Simplification Methods (하수관망 단순화 방법에 따른 SWMM모형의 2차원 침수분석)

  • Lee, Jung-Hwan;Hwang, Sung-Hwan;Moon, Hyeon-Tae;Moon, Young-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.187-187
    • /
    • 2019
  • 서울과 같은 주요 도시지역의 하수관망은 그 규모와 구성이 크고 복잡하여 강우유출모형을 구축하는데 많은 어려움이 발생한다. 또한 많은 연구자들이 직관적으로 관망을 구축하고 단순화하고 있으며, 실무에서는 일정기준 이하의 관망을 일괄적으로 삭제하는 등의 간단한 하수관망 단순화 방법을 사용하여 강우-유출 모형을 구축하고 있다. 따라서 본 연구에서는 서울시의 주요 상습침수 구역인 도림천 유역을 대상으로 전체 하수관망을 구축하고 대상유역의 누가유역면적을 기준으로 모형을 단순화하는 단순화기법과 일정 관경 이하의 하수관을 일괄적으로 삭제하는 단순화방안을 2차원 침수분석 결과를 통해 비교하여 적절한 하수관망 단순화 방안을 찾아보고자 하였다. 각각의 하수관망 단순화 기법을 통해 3가지 규모로 나누어 모형을 단순화 하였으며 도림천 일대에 많은 침수 피해를 발생시킨 2010년 9월 21일 강우사상을 적용하여 각각의 2차원 침수결과를 침수흔적도와 비교하여 규모별 단순화 방안의 적정성을 분석하였다.

  • PDF

Architectural Design for Protecting Data in NAND Flash Memory using Encryption (암호화를 이용한 낸드 플래시 메모리에서의 데이터 보호를 위한 설계)

  • Ryu, Sikwang;Kim, Kangseok;Yeh, Hongjin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.914-916
    • /
    • 2011
  • 최근 낸드 플래시 메모리 기술의 발전으로 플래시 메모리의 용량이 증가함에 따라 다양한 장치에서 데이터 저장소로 사용되고 있으며, 하드디스크를 대체할 저장 매체로서 주목을 받고 있다. 하지만 낸드 플래시 메모리의 특성으로 인해 데이터를 삭제하더라도 일정 기간 삭제된 데이터가 메모리에 남아있게 되며, 이러한 특성으로 사용자의 중요 데이터가 보호되지 않은 상태로 저장되어 외부에 노출될 수 있다. 따라서 이런 특성을 보완하는 방법이 필요하며 본 논문에서는 낸드 플래시 메모리의 단점을 해결하기 위하여 낸드 플래시 메모리를 위한 시스템 소프트웨어인 FTL(Flash Translation Layer) 계층에서 암호화 알고리즘을 사용하여 데이터를 노출하지 않게 하는 방법을 제안한다.

A Fast Vector Quantization using Subregion-based Caches of Codeword Indexes (부영역 기반 코드워드 인덱스 캐시를 사용한 고속 벡터 양자화)

  • Kim, Yong-Ha;Kim, Dae-Jin;Bang, Seung-Yang
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.4
    • /
    • pp.369-379
    • /
    • 2001
  • 본 논문은 부영역 분할과 코드워드 인텍스의 캐시 개념을 이용하여 벡터 양자화를 위한 고속코드북 생성 및 부호화 방법을 제안한다. 제안한 방법은 인접한 입력 벡터는 대개 코드북내 특정 코드워드에 의해 나타내어지는 국부성에 바탕을 두고 있다. 초기에 모든 학습 벡터가 거리에 기반한 근접성을 이용하여 정해진 수의 부영역으로 분할된다. 각 부영역에 하나의 코드워드 인덱스 캐시가 할당되는데 이 캐시는 학습 초기에는 전체 코드북 크기에 대응하는 코드워드 인덱스를 갖는다. 학습이 진행되면서 입력 벡터가 갖는 국부성 때문에 각 부영역내 캐시중 사용되지 않는 코드워드 인덱스가 점차 발생하게 되므로 이들은 LRU(Least Recently Used) 삭제 알고리즘에 의해 제거된다. 학습이 진행됨에 따라 부영역 캐시에는 주어진 입력 벡터에 의해 참조되는 코드워드 인덱스만이 남게 되므로 한 학습 주기 동한 필요한 학습 시간이 점차 짧아지게 되어 전체적으로 코드북 생성 시간을 크게 줄일 수 있게 된다. 제안한 방법은 매 학습주기마다, 코드워드 인덱스 삭제 후보 중 주어진 부영역 중심으로부터 거리에 의해 멀리 떨어진 것부터 반만을 제거함에 따라. 복원된 영상의 화질 열화가 거의 없다. 시뮬레이션 결과 제안한 방법은 기존의 LBG 방법에 비해 화질 열화는 거의 없지만 코드북 생성 (또는 부호화) 속도를 2.6-5.4배 (또는3.7-18.8배) 향상시킨다.

  • PDF

Ablation Rate and Intrapulpal Temperature by Addition of Water Spray During Er:YAG Laser Irradiation (Er:YAG laser를 이용한 치아삭제시 물분사량이 삭제율과 치수내 온도변화에 미치는 영향)

  • Kim, Jung-Moon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.375-381
    • /
    • 2005
  • Er:YAG laser has been considered a promising alternative to dental drill and many researches indicate that adjustment to variable parameters, including water flow rate, pulse energy and pulse repetition rate, can be made to improve ablation ability and efficiency of the laser. Of these parameters, addition of water spray during irradiation has been thought to ablate dental hard tissue more rapidly and safely. The purpose of this study was to investigate tooth ablation amount by Er:YAG laser irradiation as related to varied water flow rates added and, ultimately to find the most effective water flow rate for ablation. In addition, the temperature change of pulp chamber during irradiation was also monitored on the irradiated and opposite pulpal walls, respectively. An Er:YAG laser with contact mode was employed. Extracted human molars were split into two pieces for ablation experiment. Pulse energies of 200 and 300 mJ with a pulse repetition rate of 20 Hz and 5 water flow rates (1.6, 3.0, 5.0, 7.0, and 10.0 ml/min) were applied. Each irradiation was performed for 3 seconds. According to these parameters, experimental groups were divided into 10 subgroups which consisted of 5 specimens. For temperature experiment, another 5 tooth-specimens were prepared in the manner that pulp chamber was open through access cavity preparation and two temperature-measuring probes were placed respectively on the irradiated and the opposite walls of pulp chamber. From the experiment on ablation amount related to different water flow rates, it was shown that the least water flow rate of 1.6 ml/min ablated more than any other water flow rates (p<0.000). When the irradiation for 3 seconds, combined with the pulse repetition time of 20Hz and the water flow rate of 1.6 ml/min was done to tooth specimen, the temperature rise was not noticeable both on the irradiated and the opposite pulpal walls (less than 3$^{\circ}C$) and there was no significant difference in temperature rise between the two pulse energies, 200 and 300 mJ. From the results of this study, it is suggested that tooth ablation with Er:YAG laser can be done effectively and safely at a energy between 200 and 300 mJ/pulse and a pulse repetition rate of 20 Hz when the lasing is conjugated with the water flow rate of 1.6ml/min.

List Locking Protocol for XML Data Sharing (XML 데이터 공유를 위한 리스트 잠금 프로토콜)

  • Lee Eunjung
    • The KIPS Transactions:PartD
    • /
    • v.11D no.7 s.96
    • /
    • pp.1367-1374
    • /
    • 2004
  • For sharing XML data by many users, a way of concurrency and access control is required for isolating update actions such as inserting and deleting subtrees. Exisiting locking mechanisms as 2PL or MGL suffer low concurrency when applied to tree structures. In this paper, list data subtrees model is proposed based on the semantics expressed in DTD. In this model, tree updating actions such as inserting and deleting subtrees are considered only for the repetitive parts of XML trees. The proposed model guarantees that the result XML tree after applying a tree updating action is always valid, even when multiple users access the tree at the same time. Also, a new locking mechanism called list lock-ing protocol is proposed. The new locking protocol is expected to show better accessility with less number of locking objects compared to the Helmer's OO2PL model. Since update actions on a shared XML tree usually applied to the repetitive parts of the tree, the proposed model is expected to provide a useful way for efficient data sharing when combined with previous locking methods on terminal node data.

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY AND TEMPERATURE CHANGES OF DENTIN (Er:YAG 레이저의 상아질 삭제효과 및 이에 따른 온도변화)

  • Im, Kwang-Ho;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.32-44
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er : YAG laser on cutting efficacy and temperature changes of dentin. We used the dentin specimens of human premolars and molars which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er : YAG laser with non-contact handpiece type delivery system under different treatment condition of irradiation energy, pulse repetition rate, and exposure time. Two procedures were conducted by the presence of water flow during lasing. The specimens were grouped by thickness of dentin. We investigated the cavity pattern, volume, and temperature change of dentin specimen to determine the cutting efficacy and temperature rise of Er : YAG laser, and obtained following results. 1. Cutting volume of dentin was increased by increasing the irradiation energy, pulse repetition rate, and exposure time(P<0.05). 2. Margins of abulated cavities were sharp and clean and floors of cavities were conical in shape and showing smooth surfaces. Upper diameter of abulated cavities were increasing as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased. A few cracks were observed on abulated surfaces under treatment condition of laser parameter with 150mJ, 5Hz, and 5sec. 3. Temperature was increased as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased, and temperature rise was decreased as dentin thickness was increased(P<0.05). 4. Temperature rise was decreased under water flow compared with no water flow during laser exposure(P<0.05). From these results, we think that the method of using a Er:YAG laser would be effective and safe in cutting dentin for clinical application.

  • PDF