• Title/Summary/Keyword: 사이클로그램

Search Result 3, Processing Time 0.016 seconds

Low Pressure Firing Tests of 75-tonf-Class Channel Cooling Thrust Chamber (75톤급 채널냉각 연소기 저압연소시험)

  • Lim, Byoung-Jik;Han, Yeoung-Min;Kim, Jong-Gyu;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.69-75
    • /
    • 2011
  • Firing tests have been carried out for a technology demonstration model of 75-tonf-class combustor which is to be used on the liquid rocket engine of a Korean space launch vehicle. Firing tests were done at 50% of the nominal flow rate because of incapability of the test facility and limit of the test bed strength. Through the low pressure firing tests of 75-tonf-class channel cooling thrust chamber, operability and stability at the ignition and combustion phases were confirmed. Additionally it was foreseen that the 75-tonf-class thrust chamber would satisfy the performance requirements.

Low Pressure Firing Tests of 75-tonf-Class Channel Cooling Thrust Chamber (75톤급 채널냉각 연소기 저압연소시험)

  • Lim, Byoung-Jik;Han, Yeoung-Min;Kim, Jong-Gyu;Seo, Seong-Hyeon;Ahn, Kyu-Bok;Kim, Mun-Ki;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.71-74
    • /
    • 2010
  • Using the technology demonstration model of 75-tonf-class combustor which is expected to be used to the rocket engine of a korean space launch vehicle, 2 times of firing tests were carried out. Firing tests were done at 50% of the nominal flow rate because of incapability of the test facility and limit of the test bed strength. Through the low pressure firing tests of 75-tonf-class channel cooling thrust chamber, reliability and stability at the ignition and combustion phases were confirmed. Additionally it was foreseen that the 75-tonf-class thrust chamber would satisfy the performance requirements.

  • PDF

Retention Time Prediction form Molecular Structure of Sulfur Compounds by Gas Chromatography (기체크로마토그래피에서 황화합물의 구조를 통한 용리시간 예측)

  • Kim, Young Gu;Kim, Won Ho;Pak, Hyung Suk
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.646-651
    • /
    • 1998
  • The molecular structure of sulfur compounds and the retention relationship are studied by gas chromatography. Analyzed sulfur compounds are, hydrogen sulfide, sulfur dioxide, carbon disulfide, ethyl mercaptan, dimethyl sulfide, iso-propyl mercaptan, normal propyl mercaptan, ethyl methyl sulfide, tert-butyl mercaptan, tetrahydrothiophene, thiophene, and 2-chlorothiophene. Multiple linear regression explains the retention relationship of molecular descriptors. In GC the temperature program is 30$^{\circ}C$ held for 10.5 min, and then increased to 150$^{\circ}C$ at a rate 15$^{\circ}C$/min. Predicted equation for relative retention time (RRT) using SAS program is as follows; $RRT=0.121bp+14.39dp-8.94dp^2+0.0741sqmw-35.78\; (N=8,\; R^2=0.989, \;Variance=0.175,\;F=66.21)$. RRTs are function of boiling point, the square root of molecular weight, molecular dipole moment, and boiling point effects mostly on RRT. The RRT is maximized at the molecular dipole moment of 0.805D, when using nonpolar columns. The planar and highly symmetric compounds are eluted slowly. The square, of correlation coefficient $(R^2)$ using SAS program, is 0.989, and the variance is 0.175 in training sets. For three sulfur compounds, the variance between observed RRTs and predicted RRTs is 0.432 in testing sets.

  • PDF