• Title/Summary/Keyword: 사용후 공기

Search Result 658, Processing Time 0.027 seconds

Surgical Treatment of Pulmonary Mucormycosis (폐 모균증의 외과적 치료)

  • Kim, Ju-Hyeon;Park, Seong-Sik;Sin, Yun-Cheol;Seong, Suk-Hwan
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.350-354
    • /
    • 1996
  • Pulmonary mucormycosis is a very rare but often fatal opportunistic fungal infection caused by the order Mucorales in class Zygomycetes. Reported overall mortality exceeds 70% and the diagnosis is often made post-mortem. We experienced 2 cases of typical form of pulmonary mucormycosis. One patient was a poorly controlled diabetic and the other suffered from acute Iymphocytic leukemia (ALL). The former was diagnosed by a bronchoscopic biopsy and the latter by a pathologic examination from the percutaneous drain of a subphrenic abscess. Both of them underwent a surgical excision of the involved lung tissue. The patient with diabetes mellitus was successfully treated by surgical resection and discharged without complications. The other with ALL underwent a second operation and was transferred to the department of internal medicine for further management of his relapse of lettkemia. Recent literat re suggests that early aggressive diagnostic effort and treatment including surgical resection in the case of localized forms of the disease results in a good prognosis.

  • PDF

A Case of Acute Respiratory Distress Syndrome Caused by Nitric Acid Inhalation (질산(Nitric Acid) 증기 흡입에 의한 급성호흡곤란증후군 1예)

  • Kim, Dae Sung;Yoon, Hye Eun;Lee, Seung Jae;Kim, Yong Hyun;Song, So Hyang;Kim, Chi Hong;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.690-695
    • /
    • 2005
  • Nitric acid is an oxidizing agent used in metal refining and cleaning, electroplating, and other industrial applications. Its accidental spillage generates oxides of nitrogen, including nitric oxide (NO) and nitrogen dioxide ($NO_2$), which cause chemical pneumonitis when inhaled. The clinical presentation of a nitric acid inhalation injury depends on the duration and intensity of exposure. In mild cases, there may be no symptoms during the first few hours after exposure, or the typical symptoms of pulmonary edema can appear within 3-24 hours. However, in cases of prolonged exposure, progressive pulmonary edema develops instantaneously and patients may not survive for more than 24 hours. We report a case of a 44-year-old male who was presented with acute respiratory distress syndrome after nitric acid inhalation. He complained of cough and dyspnea of a sudden onset after inhaling nitric acid fumes at his workplace over a four-hour period. He required endotracheal intubation and mechanical ventilation due to fulminant respiratory failure. He was managed successfully with mechanical ventilation using positive end expiratory pressure and systemic corticosteroids, and recovered fully without any deterioration in his pulmonary function.

Stabilization of Soil Moisture and Plant Growth on a Botanical Biofilter with a Wick-Typed Humidifying Apparatus (심지형 가습장치를 이용한 식물바이오필터의 토양수분 및 식물 생육의 안정성)

  • Kim, You Na;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.29 no.5
    • /
    • pp.579-587
    • /
    • 2016
  • The final goal of this research is to develop a miniaturized botanical biofilter using a wick-typed automatic humidifier for stabilizing soil moisture content (SMC) and purifying indoor air pollutants by the biofilter. This new biofilter equipped with wick-typed automatic humidifier was manufactured as more compacted design removing an absorption tower-typed humidifier compared with the previous big-sized biofilter made in 2015. This study was performed to compare changes of SMCs among floors depending on the number of wicks installed on the humidifier within the novel biofilter, and to compare changes of SMCs and plant growth parameters before and after planting Spathiphyllum wallisii ‘Mauna Loa’ on the biofilter. SMCs among floors depending on the number of wicks were similar, and all regression lines of SMCs showed almost horizontal lines because of long-term stability on SMCs. Comparing plant growth parameters of S. wallisii ‘Mauna Loa’ before planting and at 30 days after planting on the biofilter, all growth parameters were not statistically significant. Thus, SMCs of the biofilter were more stabilized using this humidifying apparatus regardless of the number of wicks than the previous biofilter using absorption tower-typed humidifying apparatus.

An Experimental Study on Pumpability Characteristics of High Strength Concrete Mixed Polymix (폴리믹스 혼입 고강도 콘크리트의 펌프압송 성상에 관한 실험적 연구)

  • Lee, Joo-Ho;Moon, Hyung-Jae;Kim, Jeong-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.509-516
    • /
    • 2012
  • The aims of this research is to develop a fire resistant admixture to enhance high-pressured pumping of high-strength concrete (HSC) with a compressive strength of 60~80 MPa. Generally, the efficiency of HSC high-pressured pumping is dramatically reduced due to entanglement of short fibers added to prevent fire spalling. Therefore, the fire resistant admixture that can facilitate pumping of fire resistant HSC is urgently needed presently. The fire resistant HSC mix is comprised of Polypropylene fiber, Nylon fiber and Polymer powder. The test results showed that the slump-flow was improved by approximately 70% of the HSC without fire resistant admixture. However, the air void content was increased slightly due to the addition. The standard design compressive strength at 28-days was satisfied, while its flexural strength was similar to the concrete without the admixture. Since the flexural strength was 12~15% of its compressive strength, the general trend of flexural to compressive strength ratio in normal concrete was maintained. Even though its elastic modulus was decreased by adding the admixture, the study results showed that the concrete can be used for construction since all of the test results exceeded the code requirements.

A Study on Durability of High Strength Concrete (고강도(高强度)콘크리트의 내구성(耐久性)에 관한 연구(研究))

  • Kim, Saeng Bin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.9-19
    • /
    • 1981
  • Using superplasticizer or the methods of autoclave curing is the most typical and practical of the ways to make high strength concrete. In this study the high strength concrete piles by way of centrifugal forming and hand compacting, are put to the freezing and thawing test after the process of autoclave curing, water curing after steam curing, or stand water curing. And the relation of such piles to durability, the rate of strength decrease, and the rate of weight variation is shown. The durability of those test piles throughout freezing and thawing test proves to be comparatively sufficient in the above-mentioned curings when the piles contain a proper quantity of air. But it is also acknowledged that without A.E agent, the high strength concrete piles of autoclave curing is higher than those of the other curing in strength, but lower in modulus of dynamic elasticity and their durability factor after the test is much lower.

  • PDF

Field Application of 80MPa High Strength Fire Resistant Concrete using Ternary Blended Cement (설계강도 80MPa 3성분계 고강도내화콘크리트의 현장적용 및 성과분석)

  • Kim, Seong-Deok;Kim, Sang-Yun;Bae, Ki-Sun;Park, Su-Hee;Lee, Bum-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.113-119
    • /
    • 2010
  • Fire resistance and field tests for high-strength concrete(HSC) of 80MPa were carried out to evaluate whether or not it shows the same material properties even in the field condition of being mass-produced and supplied. As a result, it was found that fire resistant HSCs containing composite fiber(NY, PP) of 0.075% have great resistance to fire and spalling. In the field test, before the pumping air contents, slump flow, U-box, L-flow, compressive strength, gap of hydration temperature of interior and exterior of specimen and placing ratio per hour satisfied the required properties of HSC. However, after the pumping of HSC, as slump flow and L-flow were slightly less than required criterion, they need to be improved. In terms of hydration temperature of HSC, it was found to satisfy the related criterion. Packing ability as well as placing ratio per hour of HSC, which was about $44m^3$, show outstanding results. If slump flow of developed ternary HSC is improved after the pumping it can be useful for the construction of high-rise buildings.

Experimental Verification of Implantable Middle Ear System using the Differential Electromagnetic Type Transducer (차동 전자 트랜스듀서를 이용한 이식형 인공중이 시스템의 실험적 검증)

  • 송병섭;이기찬;원철호;박세광;이상흔;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The implantable middle ear(IME) system, which has good sound quality. superior sound intelligibility and wide frequency characteristics. can resolve the sound distortion and ringing effect by sound feedback at high gain operation those are the major problems of conventional hearing aid. In this paper, we have manufactured the IME system using differential electromagnetic transducer(DET) and verified the performance of the system by carrying out vibration and animal implanting experiment. The DET was manufactured using micro-machining technology and vibration experiment of the transducer was performed to inspect whether the transducer could vibrate in accordance with the applied sound signal or not. And the result of the loaded experiment using temporal bone sampled from cadaver showed that the transducer can drive the middle ear bone and transmit the signal to inner ear After the internal unit of IME system was implanted in a dog. the auditory brainstem response (ABR) test was carried out. The result of the test indicated the Proper behavior of the IME system in the living body From the results of the experiments, it is verified that the manufactured system ewll work well when it is applied to human and a basis of clinical experiment of IME system to real human hearing impaired was be arranged.

NOVEL CNC GRINDING PROCESS CONTROL FOR NANOMETRIC SURFACE ROUGHNESS FOR ASPHERIC SPACE OPTICAL SURFACES (우주망원경용 비구면 반사경 표면조도 향상을 위한 진화형 수치제어 연삭공정 모델)

  • 한정열;김석환;김건희;김대욱;김주환
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.141-152
    • /
    • 2004
  • Optics fabrication process for precision space optical parts includes bound abrasive grinding, loose abrasive lapping and polishing. The traditional bound abrasive grinding with bronze bond cupped diamond wheel leaves the machine marks of about $20{mu}m$ rms in height and the subsurface damage of about 1 ${mu}m$ rms in height to be removed by subsequent loose abrasive lapping. We explored an efficient quantitative control of precision CNC grinding. The machining parameters such as grain size, work-piece rotation speed and feed rate were altered while grinding the work-piece surfaces of 20-100 mm in diameter. The input grinding variables and the resulting surface quality data were used to build grinding prediction models using empirical and multi-variable regression analysis. The effectiveness of such grinding prediction models was then examined by running a series of precision CNC grinding operation with a set of controlled input variables and predicted output surface quality indicators. The experiment achieved the predictability down to ${pm}20$ nm in height and the surface roughness down to 36 nm in height. This study contributed to improvement of the process efficiency reaching directly the polishing and figuring process without the need for the loose abrasive lapping stage.

Changes of Internal Pressure during Freezing, Frozen Storage and Thawing of Meats (식육의 동결, 냉동냉장 및 해동시 내부압력 변화)

  • Jeong, Jin-Woong;Kim, Jong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.682-687
    • /
    • 1999
  • The destruction of tissues by volume increase at food freezing is accepted as one of the factor responsible for quality damage. For this reason, the internal pressure developed in meats were investigated with a pressure transducer during freezing, frozen storage and thawing. Increasement of 6.33% for volume and $942.17\;kg/cm^2$ for density at $-20^{\circ}C$ for beef were shown. In quick and slow freezing of beef, internal pressure reached to highest point after reached to the lowest point at initial of the zone of ice crystal formation. The internal pressure was approximately $8{\sim}10\;psig$ and pressure difference was about 1 psig, which was bigger in immersion freezing than that of still-air freezing. During frozen storage of pork, internal pressure of $1.84{\sim}2.32\;psig$ occurred repeatedly as a function of sample weight at material temperature difference of ${\pm}1^{\circ}C$. The internal pressure during thawing of pork was decreased slowly after rapid increase to the maximum for less than 5min at the beginning of thawing. Internal pressure value at thawing was higher than that at freezing in most cases. Internal pressure of beef with thermal equalized freezing was about $1{\sim}4\;psig$, which was lower than that of non-thermal equalized freezing. Also, freezing time was shortened to $10{\sim}20%$.

  • PDF

A Study on the Development of High Permeability and Low Coercivity Ni-Zn Ferrite (고투자율, 저보자력을 갖는 Ni-Zn Ferrite의 개발에 관한 연구)

  • 고재귀
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.1
    • /
    • pp.13-18
    • /
    • 1997
  • The effects of the various raw material composition and sintered temperature on the physical properties of Ni-Zn ferrite have been investigated. They turned out to be spinel structure by X-ray diffraction and the size of grain from microscope was from 6 ${\mu}{\textrm}{m}$ to 16 ${\mu}{\textrm}{m}$. As the sintering temperature was increased from 1030 $^{\circ}C$ to 1070 $^{\circ}C$, the initial permeability and magnetic induction has increased and the both of Q factor and coercive force has decreased. The coercive force and curie temperature were almost the same at each specimen. Their values were about 0.20 Oe and 220 $^{\circ}C$. The frequency of specimen will used in the range from 400 kHz to 20 MHz. The basic composition of $Ni_{0.14}Zn_{0.64}Cu_{0.22}Fe_2O_4$ (specimen B) sintered at 1050 $^{\circ}C$ shows the best results at magnetic induction($B_r & B_m$).

  • PDF