• Title/Summary/Keyword: 사용자 중심 평가

Search Result 632, Processing Time 0.021 seconds

The Analyses of Geographers지 Roles and Demands in Korean GIS Industries (GIS 산업에 있어서 지리학의 역할 및 수요에 대한 분석)

  • Chang Eun-mi
    • Journal of the Korean Geographical Society
    • /
    • v.39 no.4
    • /
    • pp.643-664
    • /
    • 2004
  • This study aims to review what geographers have contributed to GIS industries and national needs. To-be-geographers and geographers are expected to meet the gap between what we have teamed in school and what we have to do after graduation. The characteristics of GIS industry in the 1990 are summarized with approximate evaluation of the contribution of geographers in each stage. Author introduced the requirement for the licenses of geomatics and geospatial engineering experts and the other licenses, which are important to get a job in GIS industry from 2003 to 2004. A set of questionnaire on the user's requirements was given to GIS people in private companies and public GIS research centers and analyzed. Author found that they put an emphasis on hands-on experiences and programming skills. no advantages or geography such as capability or integration and inter-disciplinary collaboration were not appreciated. The prospects for the GIS tend to be positive but the reflectance of the prospect was not accompanied by at the same degree of preference for geography. Most government strategies for the next ten years' GIS focus on new-growth leading industries. SWOT(strength, weakness, opportunity, threat) analysis of geography for GIS industry will give some directions such as telematics, regional marketing strategies with web-based GIS technology, location based service. That means intra-disciplinary study in geography will evoke the potentiality of GIS, compared with interdisciplinary studies.

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.