• Title/Summary/Keyword: 사무소건물

Search Result 126, Processing Time 0.027 seconds

Positioning Blueprints with Moving Least Squares Optimization (이동최소자승법 최적화를 이용한 도면 배치)

  • Kim, Jong-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.4
    • /
    • pp.1-9
    • /
    • 2017
  • We propose an efficient method to determine the position of blueprint by using a vector field with optimized MLS(Moving Least Squares). Typically, a professional architectural design office takes a long time to work as well as a high processing cost because the designer manually determines the location to place the buildings in a specific area. In order to solve this inefficient problem, we propose a method to automatically determine the location of the blueprint based on the optimized MLS method. In the proposed framework, the designer selects the desired region in the actual city data and calculates the flow of the vector based on the region. Use the optimized MLS method to extract the vector field and determine the amount of rotation of the drawing based on this field. The location of the blueprint determined by the proposed method is very similar to the flow seen when the actual building is located. As a result, the efficiency of the overall architectural design process is further improved by reducing the designer's inefficient workforce.

A Study on the Cafe Architecture Reflecting the Characteristics of Jeju (제주지역 특성을 반영한 카페건축에 관한 연구)

  • Kim, Jeongil;Kim, Hyoungjun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.6
    • /
    • pp.107-112
    • /
    • 2021
  • This study aims to analyze a cafe built by reflecting the characteristics of Jeju among the cafes in Jeju. This is to provide practical help to prospective prep entrepreneurs who want to start a cafe in Jeju. The cafe reflecting the characteristics of Jeju maintains its own competitiveness and constant interest of tourists by securing differentiation and uniqueness. In addition, by looking at the characteristics of Jeju applied to cafe architecture, the academic foundation for understanding the Jeju and applicable characteristics of Jeju were summarized. The study was conducted in parallel with literature analysis and on-site analysis, and as a result, the following contents were found. First, it is a reflection of Jeju's phenomenal materiality. Second, it is a reflection of Jeju's interpretive everyday life. Third, it is a reflection of Jeju's materiality time. In this regard, if prep entrepreneurs start a cafe that reflects the characteristics of Jeju, they can create a cafe with very specific characteristics if they integrate the three characteristics above.

Recommended Practice for Demand Factor using Regression Analysis Theory depending on Power Consumption Characteristics in Commercial Buildings (업무용빌딩의 전력소비 특성을 고려한 회귀분석이론을 이용한 수용률 기준 설정)

  • Kim, Se-Dong;Shin, Hyo-Seop;Kim, Soo-Gil;Oh, Kie-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.217-222
    • /
    • 2004
  • 고도 정보화 사회의 진전으로 전기에너지의 소비는 급격히 증가하고 있다. 특히 업무용 빌딩과 같은 전력다소비 건물에서는 전력의 효율적 이용에 의한 에너지절감은 물론 설계 단계에서의 합리적인 전기설비 설계가 요청되고 있다. 현재 우리나라의 기후 특성과 전력소비 특성을 고려한 합리적인 전기설비 설계를 위한 기초 자료가 매우 미흡한 실정이다. 본 연구에서는 합리적인 수용률 기준을 설정하기 위하여 사무소용 빌딩의 전력 소비 특성을 조사 분석하였고, 아울러 전기설비설계사무소에서 적용하고 있는 수용률을 조사 분석하였다. 조사된 자료 전체의 특징과 중심적인 경향을 알아내기 위해서 평균값, 중앙값, 표준편차, 최대 값, 최소 값, 회귀모형식, 최소제곱 평균오차 등의 확률 통계적 파라미터들을 수용률 기준 설정을 위한 특징 파라미터로 선택하였다. 그리고, 데이터의 신뢰성을 비교 분석하기 위하여 선형적인 방법과 비선형적인 방법으로 그 경향을 추정하여 곡선으로 나타내었다. 이러한 방법에 의하여 얻어진 분석 자료를 이용하여 적정 변압기 용량 설정을 위하여 데이터베이스화하였고, 변전설비용량의 합리적인 설계를 위하여 수용률 기준 적용시에 필요한 자료로 활용할 수 있으리라 사료된다.

  • PDF

A Demand-side Valuation and Application of Office lighting Dimming Control in Electricity Markets (사무소 건물의 조광제어를 통한 수요관리자원 발굴 및 전력시장에서의 활용방안에 관한 연구)

  • Kim, Jin-Ho;Kim, Seong-Cheol;Park, Jong-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.35-41
    • /
    • 2008
  • In this paper, the new demand-side evaluation of the technical potential of lighting dimming control and its applications in electricity markets have been presented. Currently, advanced power information technologies(IT) has been developed and the variations of power information technologies have widely provided the new research and business opportunities. In particular, the dimming control for the lighting devices with time-varying prices and advanced controls has its economically significant values in electricity markets. Therefore, in this paper, the authors have explored the usefulness of lighting dimming control in load management fields as well as energy efficiency fields under the changing competitive electricity market environments.

The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building (사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구)

  • 이용화
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF

A Simulation Appraisal of Energy Performance in Office Building by Different Types of Air-Conditioning (공조방식에 따른 사무소 건물의 에너지 성능 평가)

  • Choi, Jong-Dae;Choi, Dong-Suk;Yun, Geun-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.612-620
    • /
    • 2012
  • High economic growth causes increase of the building energy consumption. The energy consumption for HVAC system accounts for 40~50% of the whole building consumption. The trend for building is large-scale and high-rise. Because of the trend, the energy consumption is becoming bigger than before. Nowadays, HVAC system design are recognized as the solution for a energy-saving. This paper is focused on the energy performance evaluation of central air-conditioning system(water-based) and system air-conditioning that were applied to the office building. The systems are modeled and simulated by using EnergyPlus Software 6.0. After the Simulation, annual cooling and heating energy consumption were calculated. It was found that the system air-conditioning can reduce the energy consumption approximately 55.24% annually compared with the central air-conditioning system(water-cooled). In addition, about 46.13% of annual operating costs can be reduced by use of system air-conditioning.

A Study on the Thermal Performance Analysis of Curtain Wall Office Building Considering the Thermal Bridges (열교부위를 고려한 커튼월 사무소 건물의 열성능 해석에 관한 연구)

  • Shin, U-Cheul;Kim, Seung-Chul;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.95-100
    • /
    • 2011
  • Currently, office buildings in Korea tend to adopt as their outer wall the curtain wall structure which can be easily constructed and has beautiful external appearance as well. However, the problem is that the curtain wall structure does not have a uniform composition unlike the wall of existing reinforced concrete structures and has a frame made of metal with high heat conduction. Therefore, it is expected that the structure will be highly influenced by the thermal bridge. Thereupon, this study analyzes how to set up the composition of the wall system and heat transmission rate in consideration of the thermal characteristics of the curtain wall structure and applies it in practice by simulation in order to propose a guideline for the energy simulation method of the curtain wall structure and analyze its differences from existing simulation methods.

Application of Passive Solar Systems for Office Buildings (사무소 건물을 위한 자연형 태양열 시스템의 응용)

  • Park, Jin-Seo;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.22-28
    • /
    • 2010
  • This study analyzed the performance of passive solar system for office building. A unit model of the passive solar system was proposed in order to predict its performance under varying parameters and Seoul weather date. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the passive solar system performance of office building was determined by the insolation and the outdoor air temperature. Also the passive solar system indicate 6.7~16.2% of annual average efficiency. In the comparison with other systems of the conventional wall, mass wall could reduce the heating loads of 7.1% and trombe wall could reduce heating loads of 11.5%. Through this study, performance of passive solar system for office building was verified by numerical method. Consequently, the passive solar system could operate an important role as the alternative for saving energy consumption of office building, and the additional studies should be made through the experimental method for the commercialization.

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

A Case Study on HVAC&R Energy Efficiency in Office Buildings (사무소 건물 HVAC&R 시스템의 에너지 효율화 사례연구)

  • Cho, Jin-Kyun;Woo, Kyung-Hun;Park, Woo-Pyoung;Shin, Seung-Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2013
  • HVAC&R systems are the most energy consuming building services representing approximately half of the final energy use in the building sector. Despite their significant energy use, there is a lack of a consistent and homogeneous framework to efficiently guide research, mainly due to the complexity and variety of HVAC&R systems but also to insufficient rigour in their energy analysis. This research reviews energy consumption of HVAC&R systems with the aim of establishing a common idea for the analysis of energy efficiency. The paper focuses on energy flow of the HVAC&R which include air-conditioning, transport and heat generation system for low-energy buildings.