• Title/Summary/Keyword: 사각 입사

Search Result 34, Processing Time 0.024 seconds

The Directivity Measurement of Angle Probe by Photoelastic Visualization Method (광탄성가시화법에 의한 사각탐촉자의 지향성 평가에 관한 연구)

  • Nam, Y.H.;Date, K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.83-89
    • /
    • 1994
  • It is important for an ultrasonic testing to know the sound pressure field and the directivity of ultrasonic waves propagating in a solid. The directivity of ultrasonic wave is closely related to the sensitivity, the scanning pitch, the arrangement of angle probe, and the defect kind in ultrasonic testing. This paper describes on the directivity measurement of ultrasonic wave using ultrasonic wave visualization method. The directivity of the shear wave emitted from the angle probes were constant during propagation. The difference of directivity was existed between 2MHz and 4MHz angle probes. The centers of directivity were located backward from the incident poing and inside of the angle probe and were not changed during the wave propagation.

  • PDF

The effect of incident angle on flow around a square cylinder (박리점 변동에 따른 사각 실린더 주위 유동 해석)

  • Won, Seong-Jin;Lee, Chang-Hun;Choe, Jeong-Il
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.431-436
    • /
    • 2013
  • 본 연구에서는 정사각형으로 모델링 된 실린더 주위에 균일한 유동이 흐를 때, 나타나는 이차원 층류 유동을 분석하였다. EDISON_CFD를 이용하여 각도의 변화에 따른 사각 실린더의 박리점에 의한 주위 유동 현상을 해석하였다. 격자 분해능과 시간 간격에 따른 정확성을 분석하였다. 각도의 변화에 따른 정사각 실린더의 양력계수와 항력계수를 확인하였다. 또한 한 주기의 자료값을 평균한 유동에서 박리점의 위치 변화와 주 와흘림의 길이를 분석하였다.

  • PDF

고입사각에서의 압축기 익렬 성능 연구

  • 이기수;김석훈;최정열;김귀순
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.19-19
    • /
    • 2000
  • 가스 터빈 엔진의 주요 구성품의 하나인 압축기는 입구 유동 조건의 변화에 따른 성능 변화가 민감하므로 엔진 성능 예측 시 압축기 성능은 매우 중요한 요소라 할 수 있다. 압축기 내의 유동은 본질적으로 비정상 유동이며 역압력 구배에서 작동하는 점에서 해석이 어려운 것으로 알려져 있지만 최근 컴퓨터의 비약적인 발전에 힘입어 전산유체역학(CFD)을 이용한 압축기 익렬 유동해석에 관한 연구가 활발히 진행되고 있다. 그러나 이러한 연구는 설계 점 주위의 조건, 즉 압축기 익렬에 대한 입사각이 그다지 크지 않은 경우에 대한 것이 거의 대부분이다.(중략)

  • PDF

Nonlinearity of semiconductor optical amplifier and gain-clamping effects of Iaser-injected semiconductor optical amplifier in wavelength division mulitiplexing (파장 다중 광통신에서의 반도체 광증폭기의 비선형성과 연속파동 레이저가 입사된 반도체 광증폭기의 이득고정 효과)

  • 김동철;유건호;김형문;주흥로;한선규;주관종
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • We have numerically solved rate-equations of semiconductor optical amplifier (SOA) to understand the characteristics of SOA. The rate-equations we have used can describe injection carrier density, amplified spontaneous emission and signal photon density in spatial and time domain by dividing the cavity into multi-section. We have investigated injection carrier density, amplified spontaneous emission and signal photon density as a function of position and time in the case of single channel input in the form of square pulse. Also we have analyzed the non-linear phenomena of SOA in the case of injecting multi-channel wavelengths as in WDM. Intermodulation distortion (IMD) caused by beat among channels has significant effects on the signal distortion as the channel spacing becomes narrower, and channel crosstalk becomes larger as the power of signals increases. In the case of the injection of another CW laser whose wavelength is far enough from the signal wavelengths, the crosstalk and the output signal distortion can be significantly reduced. duced.

  • PDF

Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint (가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.378-385
    • /
    • 1995
  • The ultrasonic non-destructive testing uses the directivity of the ultrasonic pulse wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is closely related to determination of probe arrangement, testing sensitivity, scanning pitch and defect location and characterization. The paper measured the directivity of shear wave, which reflected from artificial defect located in weld metal zone in butt welded joint similar model made of pyrex glass by using visualization method. 2 MHz and 4 MHz angle probes were used to measure the directivity of reflection wave at the artificial defect. The directivity of shear waves reflected from the defect was different according to the probe position and the shape of butt welded joint. The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. The angle of reflection wave became equal to angle of incidence as increase of the height of excess metal.

  • PDF

An improved crystal rotation method for simultaneous measurement of pretilt angle and thickness of a liquid crystal layer (액정셀의 선경사각과 액정층의 두께를 함께 재는 개선된 결정회전법)

  • Son, Gong-Sook;Park, Chan;Park, Hee-Gap;Kim, Jin-Seung;Rho, Bong-Gyu;Lee, Hyong-Jong;Kim, Jae-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.213-218
    • /
    • 1996
  • An improved crystal rotation method with increased accuracy and range is proposed and experimentally verified for simultaneous measurement of molecular tilt angle and thickness of LC (liquid crystal) layer of an LC cell. The improvement is brought about by direct determination of difference between phases instead of intensities of two components of orthogonal linear polarization of the light passing through an LC cell filled with uniformly oriented molecules. By comparing the experimental data with theoretical result the thickness and pretilt angle are determined more precisely. Further improvement is brought about by use of a liquid gate filled with an index matching liquid in which the LC cell is immersed. Because of the index matching liquid reflection of light at the surfaces of an LC cell almost completely disappears and the range of angle of refraction in the LC layer increases significantly, which gives rise to increased signal to noise ration as well as decreased statistical error. With this improvement precise measurement for either very thin (<10 ${\mu}{\textrm}{m}$) and/or higher pretilt angle($\geq$10$^{\circ}$) LC cells become possible.

  • PDF

Floating electrode를 갖는 플라즈마 시스템의 수치 모델링

  • Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.129-129
    • /
    • 2015
  • Dry etcher, PECVD등의 플라즈마 공정 장비의 구조물에는 유전체로 절연된 금속판들이 사용된다. 플라즈마 이론을 보면 이들 표면의 전위는 양전하 플럭스와 음전하 플럭스가 같아서 순전류가 0이 되는 부유 전위를 갖는다. 금속과 같은 전도체의 표면은 모두 같은 전위를 가져야 한다. 일반적인 플라즈마 시뮬레이션 소프트웨어에는 이런 경계 조건이 선택 가능하지 않다. ESI사의 CFD-ACE+의 사용자 루틴 개발 기능을 이용하여 Fortran90문법으로 경계면 최인접 셀의 중심에서 구한 전자 온도와 경계면의 이온 입사 플럭스로 가중평균을 구한 이온 질량을 맥스웰분포를 가정한 부유 전위식에 대입하여 시뮬레이션을 CCP에서 구현하였다. 원형 챔버의 가장자리에 떠 있는 사각 링 전극을 가정하고 이 전극 표면이 접지 전위일때, 유전체 일때, 본 연구에서 개발한 루틴을 적용한 결과를 Ar CCP에 대해서 비교 분석하였다.

  • PDF

Design of Nonpolarizing Beam Splitter Using the Multilayer Thin Film System (다층박막계를 이용한 비편광 광분리기의 설계)

  • 한성홍
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.162-167
    • /
    • 1993
  • The reflectance and transmittance of dielectric films at nonzero angle of incidence show strong polarization effects, and for many applications these effects are not desirable. In this work, some design methods are introduced, and we designed the nonpolarizing beam splitter using the outest equivalent quarter-wave layers. During this, the reflectances are varied under the constant optical thickness.

  • PDF

Hydraulic Experiments on Reflection of Regular Waves due to Rectangular Submerged Breakwaters (사각형형상 수중방파제의 반사에 관한 수리실험)

  • Cho, Yong-Sik;Lee, Jong-In;Kim, Young-Taek
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.5
    • /
    • pp.563-573
    • /
    • 2002
  • In this study, reflection of water waves over a train of rectangular submerged breakwaters is experimentally investigated. Measured reflection coefficients of regular waves are compared with predicted coefficients obtained from the eigenfunction expansion method. Although measured coefficients are slightly smaller than predicted ones, the overall agreement is very good.

Retrodirective Antenna Array Based on Double Conversion Mixer System and Its Application to Cancellation of Electromagnetic Reflections (이중 변환 믹서 방식 역지향 배열 안테나 시스템의 반사 전자기파 상쇄 응용)

  • Ha, Jungje;Jang, Sunghoon;Lee, Yongshik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1181-1189
    • /
    • 2013
  • In this paper, a retrodirective anatenna array system is proposed and the possibility of actively cancelling electromagnetic waves based on this system is investigated. When a rectrodirective array system receives an electromagnetic wave, it can send waves in the direction of the incoming signal without prior knowledge of the direction. In applications to cancellation of radar signals, the system can generate and send signals to the radar so that it cancels the radar signals that are reflected back to the radar. In such a system, isolation between the input and output ports is a key factor that determines the effectiveness of cancellation. In this work, a dual-conversion mixer system is proposed to maximize the isolation. Since this minimizes the difference between the direction of reflection of radar signals and the transmission of cancellation signals, the effectiveness of cancellation is maximized. Experimental results for a metallic plate and metallic cylinder shows as much as 29-dB reduction in reflection for a $2{\times}2$ retrodirective array based on proposed dual-conversion mixer system, which verifies the proposed method of active cancellation.