• Title/Summary/Keyword: 빔 확대기

Search Result 13, Processing Time 0.025 seconds

Development of the 2~8X Zoom Beam Expander for the 1064 nm Laser Source (1064 nm 레이저 관원용 2~8X 줌 빔 확대기 개발)

  • Yi, Meyung-Ha;Lee. Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.23-28
    • /
    • 2008
  • Purpose: To develop the 2~8X zoom beam expander for the 1064 nm laser source. Methods: After developing the program by which the initial design values of 3-component zoom tracks can be quickly obtaind, we design and develop the zoom beam expander by applying this program and the commercial program of Sigma 2000. Results: In this study, we could develop the program by which the initial design values of zoom tracks can be quickly obtaind, and by applying this program and the commercial program of Sigma 2000 we could design and develop the zoom beam expander for 1064 nm which is able to zoom from 2${\times}$ to 8${\times}$. The developed zoom beam expander has an efficient diameter of the incidence side of 8 mm, an efficient diameter of the exit side of 32 mm, and a capacity with the finite ray aberration within 0.0001rad. Because the overall length (OAL) is restricted between 125 mm and 135 mm, the change of the whole barrel length which is caused by variations of the zoom driving becomes to be within 10 mm. Conclusions: we could develop the program by which the initial design values of zoom tracks can be quickly obtaind, and by applying this program we could design and develop the zoom beam expander for 1064 nm which is able to zoom from 2${\times}$ to 8${\times}$.

  • PDF

Simulation of Temperature Distribution and Readout Signal of Magnetic Amplifying Magnetooptical System (도메인 확장형 광자기 디스크의 온도분포 및 재생신호 시뮬레이션)

  • Yang, Jae-Nam;Jo, Soon-Chul
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.2
    • /
    • pp.65-70
    • /
    • 2004
  • Read out signal and temperature distribution of magnetic amplifying magnetooptical disk were studied. Temperature distribution of recording layer and adjacent layers were calculated when the disk was at rest. Mark size, length and location were simulated from a chain of recording beam pulses. In addition, signal amplitude depending on the shape of the marks, readout signals from the recording layer and amplified marks of the readout layer, were simulated. Simplified thermal conduction model was used to calculate the temperature distribution of recording and adjacent layers as a function of time as well as to calculate the mark size, length and location. Readout signal was calculated by the convolution of the disk reflectivity and the Gaussian beam intensity. Readout signal from the mark in the readout layer amplified to the size of the laser beam fumed out to be twice as large as the signal from the crescent shaped mark in the recording layer.

Development of Raman Laser Radar System for Aerosol and Water Vapor Measurements (에어로졸, 수증기 측정 라만 레이저 레이다 시스템 개발)

  • Park, Chan-Bong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.158-161
    • /
    • 2012
  • Raman Laser Radar system for the measurements of aerosol and water vapor concentration is developed. As a transmitting system, Nd:YAG laser with 3rd harmonic Generator and beam expander are used. The wavelength of transmitting laser is 355 nm. The receiving system is consists of 500 mm telescope, 3-channel Raman spectrometer, PMT, and signal processing module. The wavelengths of received signals are 355 nm. 387 nm, and 408 nm 이다. The measurable altitude of this system is about 3~4 km with spatial resolution of 100~200 m.

  • PDF

Increasing Surveyed Area using Tilted Multi Beam Echo Sounder (멀티빔 음향측심기의 기울임 시스템을 이용한 계측영역 확대)

  • Park, Yosup;Hong, Jun-Pyo;Kong, Seong-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5D
    • /
    • pp.739-747
    • /
    • 2011
  • The paper presents implementation & evaluation of survey method with tilted transducer of Multi Beam Echo Sounder (MBES) to increase horizontal & vertical coverage over obstructed port environments with limited physical properties of MBES. Proposed method ($25^{\circ}$ titled transducer) have some discrepancy of bathymetric profiles between normal and tilting method, but we proved average difference is less than IHO Special Order requirements with survey data at port of Dong Ho Port, Masan, Korea. For horizontal mapping coverage of total survey area ($114,961m^2$), normal method covered 53%, $60,895m^2$ of total area but tilting method covered 75%, $5.933m^2$. It is 22% efficient than normal method with similar environments. For vertical mapping coverage of total vertical structure face ($7,421m^2$), normal method covered 14%, $1,046m^2$, proposed methods covered 60%, $4,450m^2$. And we adapt longitudal steel bar to validate MBES results, and provide calibration method with titled transducer of MBES.

Design and Fabrication of Full-Scale Regenerative Cooling Combustion Chamber (${\varepsilon}$=12) of Liquid Rocket Engine for Ground Hot Firing Tests (지상연소시험용 실물형 재생냉각 연소기(확대비 12)의 설계 및 제작)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Seo, Seong-Hyeon;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.114-118
    • /
    • 2007
  • Design and fabrication of a 30-tonf-class full-scale regenerative cooling combustion chamber of a liquid rocket engine for a ground hot firing test are described. It has chamber pressure of 60 bar and nozzle expansion ration of 12 and manufactured to have a single welded structure of· the mixing head and the chamber. The material of the mixing head is STS316L which has excellent mechanical property in cryogenic condition. The chamber comprise of the cylinder, nozzle throat, and 1st/2nd nozzle parts. The material of the inner jacket is copper alloy/STS329J1/STS316L and that of the outer jacket is STS329J1. The components of· the combustor were manufactured by mechanical processing including lathing, milling, MCT, rolling and pressing. The machined components were integrated to a single body by means of general welding, electron beam welding(EBW), and brazing.

  • PDF

Inscribed Transceiver Optical System Design for Laser Radar with Zoom-type Expander (줌렌즈 광속확대기를 적용한 레이저 레이더용 송수광 내접형 광학계 설계)

  • Koh, Hae Seog;Ok, Chang Min;Hong, Jin Sug;Lee, Chang Jae;Park, Chan Geun;Kim, Hyun Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • In this paper, an optical system was designed for 3D imaging laser radar with optical scanner. In order to make it easy to scan, the system was designed to inscribe the transmitting objective lens in the receiving lens. In transmitting optics, the beam expander was designed to have a zoom mechanism so that the transmitted beam size would be 4.8 m or 6.8 m at 1 km distance, when the laser source's numerical aperture value is between 0.13 and 0.22. The beam diameter at the target 1 km away was confirmed by design program. The receiving optics for the returning beam from the target was designed for the $16{\times}16$ array detector with $100{\mu}m$ pixel width. The spot diameter in every pixel was designed and verified to be less than $55{\mu}m$. The receiving optics' obscuration ratio by transmitting optics was 11%.

The Assessment of Scattered Ray According to the Beam Thickness of Z-axis in MDCT(Multi Detector Computed Tomography) (MDCT(다배열검출기 전산화단층촬영장치)에서 Z-축의 빔 두께에 따른 산란선의 평가)

  • Ryu, Gwi-Bok;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Dong, Kyung-Rae;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • The purpose of this study is to measure scattered ray which is occurred except for Z-axis range of the detector in MDCT's iso-center and present the basic data about the standard for reduction of scattered ray. The development of MDCT brings out the enlargement of beam thickness to the patient's Z-axis, which distributes to the increase in exposure dose according to the rise of scattered ray. Also MDCT brings out the increase of scattered ray about 4times more than SDCT. To evaluate scattered ray according to the change of beam thickness on MDCT, we measured scattered ray of MDCT's Z-axis beam thickness by using one 16-slice CTs and two 64-slice CTs. We used the ionization chamber 60ml 2026C as the equipment of measurement. In our results, we found out that the change of scattered ray according to the beam thickness in the same kVp has increase of scattered ray. Secondly we found out the increase of scattered ray according to the increase of kVp. Lastly we found out the decrease of scattered ray according to the increase of the distance from the ionization chamber.

Refractometric Glucose Biosensor Incorporating a Vertically Coupled Microring Resonator in Polymeric Waveguides (수직형 폴리머 마이크로링 공진기 기반의 글루코스 바이오 센서)

  • Kim, Gun-Duk;Son, Keun-Sik;Lee, Hak-Soon;Kim, Ki-Do;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.127-131
    • /
    • 2008
  • A refractometric glucose biosensor incorporating a vertically coupled microring resonator in polymers was proposed and realized. The ring was covered with a target analyte of glucose solution with a certain concentration, so that its effective refractive index could be altered and, as a result, the resonance wavelength of the sensor was shifted. Therefore the concentration of the glucose solution can be estimated by observing the shift in the resonance wavelength. Two schemes were exploited for enhancing the sensitivity of the sensor. First, the effective refractive index of the polymeric waveguide used for the resonator sensor was adjusted to approach that of the target analyte as best as possible. Second, the ring waveguide, which serves as a crucial sensing part, was appropriately over-etched to enlarge its contact area with the analyte. The proposed resonator sensor was designed with the beam propagation method. The refractive indices of the core and cladding polymer involved were 1.430 and 1.375 respectively, leading to the waveguide's effective refractive index of ${\sim}1.390$, which is faiirly close to that of the glucose solution of ${\sim}1.333$. The prepared ring resonator with the $400-{\mu}m$ radius exhibited the free spectral range of 0.66 nm, the bandwidth of 0.15 nm, and the quality factor of 10,000. For the sensor operating at 1,550 nm wavelength, the achieved sensitivity was as great as 0.28 pm/(mg/dL), which is equivalent to 200 nm/RIU.

The Rejection of the GPS Interference Mirror Image by using the Three-dimensional Array Antenna (3차원 구조 배열안테나를 적용한 GPS 간섭신호 미러 이미지 제거)

  • Kim, JunO;Lee, Sang Jeong
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • Recently, GPS(Global Positioning System) array antenna technology is generally used and widely adopted as a national infrastructure structure and aero-vehicles for protection the GPS signal reception. Until now, the 2-dimensional planar array is universally used for its applications in the array antenna signal processing, however relatively higher altitude air vehicles such as UAV experiences additional null zones induced by low altitude GPS interferences which is located in a symmetry zone of antenna horizontal plane and this could make the receiving antenna pattern coverage reduction. In this paper, we improved 20% of the beam pattern receiving performance and 13 dB correlation value improvement by eliminating the interference mirror images.

A Study on Property Change of Auto Body Color Design (자동차 바디컬러 디자인의 속성 변화에 관한 연구)

  • Cho, Kyung-Sil;Lee, Myung-Ki
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.253-262
    • /
    • 2006
  • Research of color has been developed and also has raised consumer desire through changing from a tool to pursue curiosity or beauty to a tool creating effects in the 20th century. People have been interested in colors as a dynamic expression of results since the color TV appeared. The meaning of colors has been recently diversified as the roles of colors became important to the emotional aspects of design. While auto colors have developed along with such changes of the times, black led the color trend during the first half of the 20th century from 1900 to 1950, a transitional period of economic growth and world war. Since then, automobile production has increased apace with the rapid economic growth throughout the world and automobiles became the most expensive item out of the goods that people use. Accordingly, increasing production induced facility investment in mass production and a technology leveling was achieved. Auto manufacturing processes are very complicated, auto makers gradually recognized that software changes such as to colors or materials was an easier way for the improvement of brand identity as opposed to hardware changes such as the mechanical or design components of the body. Color planning and development systems were segmented in various aspects. In the segmentation issue, pigment technology and painting methods are important elements that have an influence on body colors and have a higher technical correlation with colors than in other industries. In other words, the advanced mixture of pigments is creating new body colors that have not existed previously. This diversifies the painting structure and methods and so maximizes the transparency and depth of body colors. Thus, body colors that are closely related to technical factors will increase in the future and research on color preferences by region have been systemized to cope with global competition due to the expansion and change of auto export regions.

  • PDF