Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

A Study of Energy Dependency in Intensity Modulated Radiation Therapy of Lung Cancer (폐암환자의 세기조절방사선치료에서 에너지에 따른 선량분포 특성 비교)

  • Kim, Sung-Kyu;Kim, Myung-Se;Yun, Sang-Mo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.191-199
    • /
    • 2008
  • PTV considered for the energy, dose distribution exposed to lung and spinal cord, and the characteristic of DVH(Dose Volume Histogram) were compared and investigated by planning the intensity modulated radiation therapy (IMRT) using the photon energies of 6 MV and 10 MV according to tumor location like as the anterior, middle, and posterior regions of lung, and the mediastinum region in lung cancer patients. Our institution installed the linear accelerator (Varian 21 EX-s, USA) equipped with 120 multileaf collimator for lung cancer patients, which is producing the photon energies of 6 MV and 10 MV, and radiation therapy planning was performed with ECLIPSE system (Varian, SomaVision 6.5, USA), which support inverse treatment planning. The tomographic images of 3 mm slice thickness for lung cancer patients were acquired using planning CT, and acquired tomographic images were sent to the Varis system, and then treatment planning was performed in the ECLIPSE system. The radiation treatment planning of the IMRT was processed from various angles according to the regions of the tumor, and using various beam lines according to the size and location of the tumor. The investigation of the characteristic of dose distributions for the energy of 6 MV and 10 MV according to tumor locations in lung cancer patients resulted that the maximum dose of 10 MV energy was 1.2% less than that of 6 MV energy without depending on the tumor location of lung cancer, and the reduction effects of MU were occurred from 10 to 25 MU. Radiation dose exposed to the lung satisfied the less 30% of V20, however radiation dose in 6 MV energy was from 0.1% to 0.5% less than that in 10 MV energy. Radiation dose exposed to the spinal cord for 6 MV energy was from 0.6% to 2.1% less than that for 6 MV energy.

  • PDF

The Fabrication and Evaluation of HgI2 Semiconductor Detector as High Energy X-ray Dosimeter Application (고에너지 X선 선량계 적용을 위한 TiO2 첨가된 요오드화수은 반도체 검출기 제작 및 평가)

  • Choi, Il Hong;Noh, Sung Jin;Park, Jung Eun;Park, Ji Koon;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.383-387
    • /
    • 2014
  • In this paper, for a new detection system development with the better accurate dose evaluation and beam distribution imaging using the small field irradiation of linear accelerator, the compound semiconductor based detection sensors were fabricated and the performance evaluation was investigated. The special particle-in-binder sedimentation was used for a large area film sensor fabrication. The detection properties for high energy x-rays were investigated from a dark current, an output current, a rising time, a falling time, and response delay measurement. The experimental results, the $TiO_2$ mixed $HgI_2$ sensor showed the best electrical characteristics than $PbI_2$, PbO, pure $HgI_2$. Linearity, repeatability, and accuracy tests from LINAC were tested, the $TiO_2$ mixed $HgI_2$ sensor showed the better performance than the commercially available dosimetry devices.

Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position (후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구)

  • Yoon Sang Min;Lee Sang-wook;Ahn Seung Do;Kim Jong Hoon;YE Byong Yong;Ra Young Shin;Kim Tae Hyung;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2003
  • Purpose : To explore a 3D conformal radiotherapy technique for a posterior fossa boost, and the potential advantages of a prone position for such radiotherapy. Materials and Methods :A CT simulator and 3D conformal radiotherapy Planning system was used for the posterior fossa boost treatment on a 13-year-old medulloblastoma patient. He was placed In the prone position and Immobilized with an aquaplast mask and immobilization mold. CT scans were obtained of the brain from the top of the skull to the lower neck, with IV contrast enhancement. The target volume and normal structures were delineated on each slice, with treatment planning peformed using non-coplanar conformal beams. Results : The CT scans, and treatment In the prone position, were peformed successfully. In the prone position, the definition of the target volume was made easier due to the well enhanced tentorium, In audition, the posterior fossa was located anteriorly, and with the greater choice of beam arrangements, more accurate treatment planning was possible as the primary beams were not obstructed by the treatment table. Conclusion : .A posterior fossa boost, in the prone position, Is feasible in cooperating patients, but further evaluation is needed to define the optimal and most comfortable treatment positions.

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.