• Title/Summary/Keyword: 비침습적 검사

Search Result 226, Processing Time 0.029 seconds

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

The Relationship between Perceived Stress Scale and Carotid Intima-Media Thickness Using Ultrasonography in University Students (대학생들의 스트레스 지각 정도와 경동맥 내막-중막 두께의 관계 연구)

  • Kim, Dae-Sik;Sung, Hyun-Ho;Lee, Jong-Woo;Cho, Eun-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.308-315
    • /
    • 2017
  • Carotid artery intima-media thickness (CIMT) test is a standardized ultrasound procedure that screens for and monitors atherosclerosis in a safe and non-invasive manner, even in individuals with no symptoms of heart disease. The purpose of this study was to research the relationship between CIMT, as measured by ultrasonography, and the degree of individual perceived stress. There was a total of 168 (male: 46, female: 122) university students in Suwon-si, Gyeonggi-do, Korea, without other diseases. Written informed consent was obtained from all participants. CIMT was measured in the right and left common carotid arteries 1 cm below the bifurcation, and internal carotid artery, using non-invasive high-resolution Medison Accuvix V20 prestige ultrasound equipment and perceived stress, was measured with the 10-item PSS (Perceived Stress Scale) questionnaire. This study indicates that PSS may be appropriate to estimate perceived stress levels and weight. Failure to control stress anxiety could lead to weight and CIMT soaring to dangerous levels, resulting in a myocardial infarction or cerebrovascular accident. There was a statistically significant difference between left CIMT (p<0.05) and weight (p<0.05) according to each stress classification. The results of this study suggest that the weight measurement is influenced in part by one's generalized stress levels. Future continuous studies should be conducted to test the influences of perceived stress and generalized anxiety on CIMT when these are many continuous variables.

Role of enzyme immunoassay for the Detection of Helicobacter pylori Stool Antigen in Confirming Eradication After Quadruple Therapy in Children (소아에서 4제요법 후 enzyme immunoassay에 의한 Helicobacter pylori 대변 항원 검출법의 유용성에 대한 연구)

  • Yang, Hye Ran;Seo, Jeong Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Purpose: The Helicobacter pylori stool antigen (HpSA) enzyme immunoassay is a non-invasive test for the diagnosis and monitoring of H. pylori infection. But, there are few validation studies on the HpSA test after eradication in children. The aim of this study was to assess the diagnostic accuracy of HpSA enzyme immunoassay for the detection of H. pylori to confirm eradication in children. Methods: From January 2001 to October 2003, 164 tests were performed in 146 children aged 1 to 17.5 years (mean $9.3{\pm}4.3$ years). H. pylori infection was confirmed by endoscopy-based tests (rapid urease test, histology, and culture). All H. pylori infected children were treated with quadruple regimens (Omeprazole, amoxicillin, metronidazole and bismuth subcitrate for 7 days). Stool specimens were collected from all patients for the HpSA enzyme immunoassay (Primier platinum HpSA). The results of HpSA tests were interpreted as positive for $OD{\geq}0.160$, unresolved for $$0.140{\leq_-}OD$$<0.160, and negative for OD<0.140 at 450 nm on spectrophotometer. Results: 1) One hundred thirty-one HpSA tests were performed before treatment. The result of HpSA enzyme immunoassay showed three false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value of HpSA enzyme immunoassay before treatment were 96.4%, 97.1%, 90%, and 99%, respectively. 2) Thirty-three HpSA enzyme immunoassay were performed at least 4 weeks after eradication therapy. The results of HpSA enzyme immunoassay showed two false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value after treatment were 88.9%, 91.7%, 80%, and 95.7%, respectively. Conclusion: Diagnostic accuracy of the HpSA enzyme immunoassay after eradication therapy was as high as that of the HpSA test before eradication therapy. The HpSA enzyme immunoassay was found to be a useful non-invasive method to confirm H. pylori eradication in children.

  • PDF

Feature Extraction Program for Prostate Parameters (전립선 진단을 위한 특징 파라미터 추출 프로그램)

  • Choi, Hwan-Yong;Lee, Dae-Jong;Cha, Eun-Jong;Cho, Young-Im;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.5
    • /
    • pp.659-665
    • /
    • 2008
  • Uroflowmetry is a non-invasive and easily performed method to diagnose the benign prostate hypertrophy(BPH) which is frequently found in the aged men. There are some manufactures to provide a diagnosis tool for the benign prostate hypertrophy. Conventional products, however, render only the result of parameters related with prostate hypertrophy, not additional information such as the uroflowmetry variation and related personal information. In this paper, we developed an effective system for feature extraction of prostate hypertrophy as well as online program for wireless networked database management which can be used under ubiquitous environments and Labview based Window program.

Recent Updates of Abbreviated MRI for Hepatocellular Carcinoma Screening (간세포암 감시를 위한 단축 자기공명영상의 최신지견)

  • Jeong Woo Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.280-297
    • /
    • 2021
  • International guidelines recommended screening with ultrasonography (US) every 6 months for patients at risk for hepatocellular carcinoma (HCC). However, US demonstrates low sensitivity for the early detection of HCC. Magnetic resonance imaging (MRI) plays an important role in the noninvasive diagnosis of HCC, but it is not suitable for surveillance due to its lengthy examination and high cost. Therefore, several studies have been using various abbreviated MRI strategies, including noncontrast abbreviated MRI, dynamic contrast-enhanced abbreviated MRI, and abbreviated MRI using hepatobiliary phase image for HCC surveillance. In this article, we aim to review these various strategies and explore the future direction of HCC surveillance considering the cost-effectiveness aspect.

Thermographic Evaluation of Beating Process of Experimentally Induced Infectious Arthritis in Horses (실험적으로 유발한 말 감염성 관절염의 치유경과에 대한 체열학적 평가)

  • Yang Young-Jin;Nam Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.22-30
    • /
    • 2006
  • This study was carried out to assess the usefulness of thermography for diagnosis and healing process of musculoskeletal disorder in horses. Horses with experimentally induced infectious arthritis were treated with bee venom or antibiotics for 5 weeks from 24 hours after inoculation of Staphylococcus aureus, the effectiveness of the 2 therapeutic drugs treatment was similar to each other. Thermographic evaluation was similar to any other tests, because the thermal pattern tend to return to normal with declining similar to those of clinical signs, laboratory experiments and healing of the lesion. This ability to assess inflammatory change noninvasively make thermography an ideal imaging tool to aid in the diagnosis of certain lameness condition or musculoskeletal disease in horses. These results suggested that thermographic evaluation in horses with musculoskeletal disorders were useful for diagnosis and helpful for monitoring of healing process.

Comparison of the Right-to-left Shunt Test by Transcranial Doppler Based on the Addition of Blood and Patient Posture (경두개 초음파를 이용한 좌우단락검사 시 Blood 사용 유무와 환자 자세에 따른 실증적 결과 비교)

  • Kun-Woo KANG;Eui-Jeong LEE;Hyun-Kyung LEE;Eun-Son LEE;Yang-Hee LIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Using transcranial doppler ultrasonography (TCD) to measure the presence or absence of abnormalities in patent foramen ovale (PFO) is more effective than transesophageal echocardiography (TEE) because it is simple, inexpensive, and non-invasive. Thus, it can be a good alternative test in cases where it is difficult to perform TEE or in groups at a high risk of complications. Therefore, in this study, we sought to assist in arriving at a diagnosis by suggesting an appropriate method through the comparison of empirical results according to the presence or absence of blood use and varying patient posture. The results were compared depending on the patient's posture and whether blood was used. Patients in whom both middle cerebral arteries were observed were targeted. In cases where the temporal window was defective, it was replaced with basilar artery and compared. There were higher positivity rate and accuracy for sitting position using valsalva maneuver (VM) than for Resting and supine position using VM. Therefore, if it is possible to perform a sitting position using VM with a mixture of blood, it would be a good idea to perform it.

Usefulness of the $UBC^{TM}$ (Urinary Bladder Cancer) Test Compared to Urinary Cytology for Transitional Cell Carcinoma of the Bladder in Patients with Hematuria (혈뇨 환자의 방광암 진단에서 $UBC^{TM}$ (Urinary Bladder Cancer) 검사의 유용성)

  • Gil, Myung-Cheol;Kang, Do-Young;Seong, Youl-Koon;Jung, Se-Il;Kwon, Hyon-Young;Jung, Gyung-Woo;Kim, Duk-Kyu;Roh, Mee-Sook;Hwang, Tae-Ho;Yoon, Jin-Han
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.192-197
    • /
    • 2001
  • Purpose: Urinary cytology and cystoscopic exam are effective methods for diagnosis of transitional cell carcinoma(TCC). But the former shows drawbacks such as the need for a well-trained examiner, and wide imprecision related to the variability of microscopic exam; the latter is an invasive method. $UBC^{TM}$ test detects the epitope on specific cytokeratin fragments released from epithelium of bladder cancer by immunoradiometric assay. We compared $UBC^{TM}$ test with urinary cytology for diagnosis of TCC to evaluate the utility of $UBC^{TM}$ test. Materials and Methods: Eighty-four patients with hematuria were included in our study. $UBC^{TM}$ tests (IDL Biotech, Sweden) were assayed in mid-stream urine according to the ordinary assay protocol. Nineteen patients were confirmed as TCC by cystoscopic examination and underwent transurethral resection (Group A). Other patients had various benign urinary tract conditions (Group B). Samples were considered positive as the $UBC^{TM}$ concentration was greater than $12{\mu}g/L$. Results: $UBC^{TM}$ levels were significantly different between group A ($95.9{\pm}166.4\;{\mu}g/L$) and group B ($19.2{\pm}85.6{\mu}g/L$) (P<0.001). Sensitivity for diagnosis of TCC was 89.5% (17/19) in UBC test and 47.4% (9/19) in cytology (p<0.05). Specificity for diagnosis of TCC was 81.5% (53/65) in $UBC^{TM}$ test and 100% (65/65) in cytology. $UBC^{TM}$ test was significantly more sensitive in stage Ta, $T_1$ tumors (84.6 vs 38.5%, p<0.05) and in grade I (83.3% vs 16.7%, p<0.05) than cytology. $UBC^{TM}$ test showed a tendency to be more sensitive as the grade was higher (83.3% in Grade I, 90% in Grade II and 100% in Grade III). Conclusion: $UBC^{TM}$ test could be a useful method in distinguishing TCC from other benign genitourinary diseases. Moreover, $UBC^{TM}$ test could be an especially valuable marker for diagnosis of TCC in patients with early TCC of low grade TCC compared to urinary cytology. Therefore, mbined use of $UBC^{TM}$ test in association with cytology is helpful to overcome the limited sensitivity of cytology.

  • PDF

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

The Development of Diagnosis for Atopic Dermatitis by Evaluating the Expression of Skin Barrier Proteins Using a Non-Invasive Method (비침습적 피부장벽단백질 측정을 통한 아토피 피부염의 진단 및 유용성)

  • Kim, In Sik;Lee, Ji-Sook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.395-400
    • /
    • 2017
  • Atopic dermatitis is a chronic inflammatory skin disease caused by a variety of genetic and environmental factors, dysregulation of immunological response, as well as dysfunction of the skin barrier proteins. The purpose of this study is to develop an ELISA kit suitable for evaluating the expression of skin barrier proteins. Proteins were obtained from the skin via AriNo and D-Squame patches. The efficiency of protein collection from the skin, using the Arino patch, was shown to be more effective than using D-Squame; while the efficiency of lysis using 0.1% Triton-X100 was higher than that of other lysis solutions, including 0.1 M Tris-HCL, 0.1% Tween-20, and 5 mM KOH. Recombinant skin barrier proteins, such as filaggrin and involucrin, were produced by molecular biological methods. Monoclonal antibodies against filaggrin and involucrin were produced by immunization of mice, fusion of spleen cells and myeloma cells, as well as a selection of antibody-producing hybridoma cells. The filaggrin expression in the skin of subjects suffering from atopic dermatitis was lower than that in normal mice. Involucrin expression was not altered between normal individuals and subjects with atopic dermatitis. These findings contribute to an elucidation of the importance of the skin barrier protein expression in atopic dermatitis and the development of a diagnostic kit for atopic dermatitis.