• Title/Summary/Keyword: 비접촉 전류센서

Search Result 21, Processing Time 0.046 seconds

Non-Contact Current Sensor Fabricated with LC Resonators (LC 공진소자를 이용한 비접촉 전류센서 연구)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.137-141
    • /
    • 2016
  • There is a growing demand for non-contact current measurements for efficient use of electrical power and energy saving. In this study, I propose a non-contact current sensor using LC resonance by a resonance circuit composed of a sensor coil and 2 coupling coils for enabling a wireless measurement. The inductance of the sensor coil, which could be changed by applied current, causes the change of resonance frequency of the resonance circuit. A pair of magnet was attached to the ferrite core to apply a bias magnetic field that enabled the determination of the current direction. We obtained an output voltage change of 18 V with the current of -3~3 A. But, the output was nonlinear. In order to realize the non-contact current measuring method proposed in the present study, there is a need for a strict investigation of linearity and resolution for the future study.

Noncontact Measurement of the current distribution on 4 HTS parallel wires (4 병렬 고온초전도 선재의 비접촉 전류분류 측정)

  • Byun, Sang-Beom;Lee, Seung-Wook;Kim, Woo-Seok;Choi, Kyeong-Dal;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.945-946
    • /
    • 2007
  • 여러 가닥의 병렬선재에 전류가 흐를 때 각 가닥에 흐르는 전류가 균일한지 알아보기 위해 각 선재의 흐르는 전류를 측정하는 방법으로 홀센서를 이용한 비 접촉식 측정 방법이 있다. 홀센서를 이용하여 전류를 측정하기 위해 4가닥의 병렬선재를 구성하고 일정한 위치에서 자장을 측정하기 위해 센서 홀더를 제작 하였다. 선재에 전류를 흘려주어 발생되는 자장을 홀센서로 측정하였고, 측정된 자장 값을 통해 행렬식을 만들었다. 완성된 행렬식을 이용하여 각 선재에 흐르는 전류 값을 계산하고, 실제 각 선재에 흐르는 전류 측정값과 비교하여 병렬선재에서의 전류분류의 비접촉 측정의 가능성을 살펴본다.

  • PDF

Anti-Pinch System for Power Window Based on Current Information (전류 정보 기반의 파워 윈도우용 안티핀치 시스템)

  • Wibowo, Wahyu Kunto;Jeong, S.K.;Kum, J.S.;Park, S.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.98-105
    • /
    • 2012
  • 안티핀치 시스템은 파워 윈도우 상승 시에 인체의 특정 부위가 창문 틈 사이에 끼여 발생하는 치명적인 사고를 방지하기 위한 안전 시스템이다. 이러한 안티핀치 시스템은 물체의 끼임을 검출하는 센서 방식에 따라 접촉식과 비접촉식 두 가지로 크게 구분된다. 본 논문에서는 접촉식의 한 방법으로 전류 정보에 의해 강화된 미국의 안전 규정 FMVSS 118-S5를 만족하는 안티핀치 시스템을 제안한다. 안티핀치 시스템에 사용된 전류 정보는 추가적인 장치의 부착 없이도 기존의 파워 윈도우용 모터 드라이브에 내장된 과전류 검출용 전류 센서를 이용하여 쉽게 얻을 수 있다. 또한 전류 정보는 물체의 끼임을 신속히 검출, 반영함으로써 안티핀치 시스템에 요구되는 반전력 저감에 기여한다. 특히, 본 논문에서는 전류의 임계값이 모터 경년 변화나 운전 조건에 따라 변동하는 문제점을 개선하기 위해 핀치 상태를 효과적으로 판정할 수 있는 자동 임계값 설정 방법을 제안한다. 마지막으로 다양한 실험 및 시험을 통해 제안된 안티핀치 시스템이 FMVSS 118-S5를 만족함을 보인다.

Implementation of Low Noise Current Sensor using Low Pass FIR Filter (저역통과 FIR필터를 이용한 저잡음 전류 센서 구현)

  • Kim, Jeong-Hwan;Lee, Seong-Jin;Choi, Yong-geon;Han, Seong-Gye;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.499-502
    • /
    • 2017
  • The needs of efficient electricity use and current measurement for electrical safety have been increased. Hence, the current sensor is used, especially non-contact current sensor which can measure the current without blocking the circuit using hall effect. However, the accurate measuring of the current sensor is inhibited due to the inflow of various noises in this current sensor. In this article, a stronger current sensor against the noise is proposed using low pass FIR filter to the existing current sensor. FIR filter was designed to block the range over the certain frequency at the output of the current sensor to eliminate the external noises, and so on. As a result, more accurate and close measurements were possible.

  • PDF

Development of Built-in Sensor Breaker include Communications Function (통신 기능을 갖는 센서 내장형 차단기 개발)

  • Lee, Sang-Ick;Ju, Nam-Kyu;Kim, Gi-Hyun;Bae, Seok-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2168_2169
    • /
    • 2009
  • 산업이 발달함에 따라 전기는 우리 일상생활에 있어 없어서는 안 될 중요한 요소이나, 전기는 시각적인 흐름을 볼 수가 없어 전기설비나 전기용품 사용중에 발생할 수 전기사고에 대해서 사전에 사고를 감지하고 예측하기 어려워 사고 위험성에 대하여 무방비 상태가 되나, 전력 사용량, 전기 위험도 분석 등에 대한 기술은 그에 미치지 못하고 있다. 이에 전기 사용 상태에 대한 분석이 가능하기 위해서는 분전반내부에 분석 회로장착이 필요하며, 전류 분석을 위해서는 전류센서(CT)가 구성되어 져야 하고, 이 전류신호는 data cable을 통하여 분석보드로 전송 되어져야 한다. 이는 수배전반 내부에 전력 케이블과의 접촉 문제, 결선 의 어려움 등이 있어 이를 해결 하고자 통신기능을 갖는 센서 내장형 차단기를 개발하고자 한다.

  • PDF

High-Accuracy Current Sensing Technique Based on Magnetic Sensors for Three-Phase Switchboards (삼상 배전반에서 자기센서 기반의 고정밀 전류 측정 기법)

  • Lee, Sungho;Kim, Taemin;Kim, Namsu;Ahn, Youngho;Lee, Sungchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.993-998
    • /
    • 2017
  • In this paper, a high-accuracy current sensing technique for three-phase current paths in an electrical switchboard is proposed. Conventional open-style current sensors using magnetic sensors show inaccurate sensing performance with more than 10% error due to undesired magnetic field interference from neighboring paths. To increase accuracy, large and expensive current transformers with large permeabilities have been used, which increased the cost and size. The proposed technique can improve the measured magnetic field by the calculation of magnetic interference effect from neighboring current paths. The relationship between neighboring magnetic fields and the desired magnetic field is theoretically analyzed in a general case. The proposed technique is verified using magnetic field simulations in a three-phase busbar environment.

Effect of a current distribution on the AC loss and Noncontact Measurement of the current distribution (교류 손실에 미치는 전류 분류의 영향 및 비접촉 전류 분류 측정)

  • Byun, Sang-Beom;Lee, Seung-Wook;Kim, Woo-Seok;Choi, Kyeong-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.80-81
    • /
    • 2007
  • 초전도 선재에 대 전류를 흘리기 위해서는 여러 가닥의 초전도 선재를 병렬로 연결하여 사용하여야 한다. 본 논문에서는 교류 손실에 미치는 전류 분류의 영향을 알아보기 위해 6가닥의 병렬선재 분기대를 제작하고, 전류분류가 균일 할 때와 불 균일 할 때의 임계전류 및 교류 손실의 차이를 확인하였다. 홀 센서를 이용하여 각 가닥의 선재에 흐르는 전류의 값을 예측할 수 있는 방법을 제시하였다.

  • PDF

Practical Application of Image Stage Gauge (영상수위계 실용화)

  • Kim, Won;Kim, Chi-Young;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.560-564
    • /
    • 2007
  • 하천 수위 측정을 위해서 우물통을 기본으로 하는 부자식, 초음파식, 기포식, 압력식, 레이다식 등 다양한 장비가 사용되고 있다. 이와 같은 장비는 모두 간접적인 방법으로 수위를 측정하기 때문에 기준값을 바탕으로 보정이 필요하며, 장비의 특성에 따라 여러 가지 장단점을 지니고 있다. 부자식의 경우 오래 전부터 사용되어 안정적으로 수위를 측정할 수 있는 것으로 평가되고는 있으나 우물통 막힘 등으로 인해 오측 혹은 결측이 발생하는 경우가 있다. 최근에 많이 사용되고 있는 센서식 장비의 경우에는 센서에 대한 정기적인 보정이 필요하며, 일부 장비의 경우 온도에 따라 측정값이 변화하는 단점이 있다. 수위 측정 방식은 접촉식과 비접촉식으로 나누어 볼 수 있다. 접촉식의 경우 물속에 센서가 위치하고 있기 때문에 홍수시 센서 유실 및 고장의 우려가 있으며, 잦은 고장의 원인이 되기도 한다. 비접촉 방식인 초음파나 레이다 수위계의 경우 온도에 따라 보정이 필요하거나 수면과의 거리에 커지면 오차가 커지는 경향을 지니고 있다. 또한 이와 같은 간접방식에 의한 수위측정 방법은 수위가 많이 변화하는 경우 실제 수위와 측정되는 수위가 일치하는지를 확인하는 것이 불가능한 단점도 있다. 본 연구에서는 최근에 많이 일반화되고 있는 영상처리 기술을 이용하여 자동적으로 수위를 측정하는 장비인 영상수위계를 개발하였다. 영상수위계는 카메라(CCTV 포함)에 의해서 수위표를 촬영하여 직접 수위값으로 변환하는 원리를 사용하고 있어서 기존 수위측정 시설과는 달리 수위표를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 수위표를 육안으로 확인할 수 있기 때문에 측정된 수위를 검증할 수 있어 수위측정의 정확성을 한층 높일 수 있다. 그리고 수위표 영상과 더불어 수위표 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 본 연구에서 개발한 영상수위계는 한강홍수통제소 관할의 전류, 청담대교 등 4개소 낙동강 홍수통제소 2개소, 지자체 등에 적용되었으며, 적용 결과 비교적 안정적이면서 정확하게 수위를 측정하는 것으로 나타났다. 한편 기존 CCD 카메라 이외에 CCTV를 이용한 영상수위계를 개발하여 영상의 화질 개선뿐 아니라 하천화상 감시 기능을 강화하였다.

  • PDF

A Study on the Development and Characteristics Evaluation of Non-Contact HFCT Sensor for Partial Discharge Measurement (부분방전 측정용 비접촉식 HFCT 센서개발 및 특성평가에 관한 연구)

  • Sang-Bo Han
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.131-135
    • /
    • 2024
  • In this study, the sensor such as current transformer type was developed for measuring non-contact partial discharge in power electrical facilities, and the results of the characteristic evaluation were discussed. The frequency response characteristics of the HFCT sensor were shown to be measurable from 20 [kHz] to 20 [MHz]. The average sensitivity for the positive direction was 0.308 [mV/pC], and the negative direction was 0.459 [mV/pC]. Which showed that the sensitivity for the negative direction was better than that for the positive direction. The developed HFCT sensor is possible to measure very small partial discharge pulse signals and can be measured various types of partial discharge that may occur at power electrical facilities.