• Title/Summary/Keyword: 비접촉측정

Search Result 276, Processing Time 0.026 seconds

Sensitivity of non-contact Temperature Measurement Using Temperature Sensitive Ferrite (감온 페라이트를 이용한 비접촉 온도측정시스템의 감도특성)

  • Shin, K.H.;Kim, Y.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • To construct the non-contact temperature detection systems, LC resonance type sensors composed of temperature sensitive ferrite inductors and capacitors were used, and their wireless temperature detection performances were investigated. The temperature was wirelessly detectable using the fabricated LC resonance sensors with a transmitter and receiver, because their inductances and resonance frequencies were changed according to the temperature dependance of permeability of the ferrites. The sensitivity of the system was decreased with the distance i between transmitter and receiver as a ratio of the l$^6$.

카본나노튜브 AFM의 비접촉측정에 관한 연구

  • ;;;;Mark Strus;Arvind Raman
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.132-132
    • /
    • 2004
  • 카본나노튜브는 나노튜브의 종류에 따라 1~10nm의 직경과 수 $\mu\textrm{m}$정도의 길이를 가지는 고종횡비(high aspect ratio)가 가능하며, 고강성, 전기화학적 내성, 마모에 대한 강인성 때문에 원자력간 현미경(AEM)의 프로브로서 이상적인 재료로 인식되어 왔다. 따라서 단백질이나 DNA를 측정하는 바이오 분야, 나노 일렉트로닉스 분야, 나노 구조 측정분야 등 나노 관련 측정분야에서 점차 그 활용도가 높아 져가고 있다. 특히 100nm이하의 반도체의 CD(critical Dimension)을 측정하는데 있어서 나노튜브는 가장 이상적인 후보라고 할 수 있겠다.(중략)

  • PDF

Non-Contact Current Sensor Fabricated with LC Resonators (LC 공진소자를 이용한 비접촉 전류센서 연구)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.137-141
    • /
    • 2016
  • There is a growing demand for non-contact current measurements for efficient use of electrical power and energy saving. In this study, I propose a non-contact current sensor using LC resonance by a resonance circuit composed of a sensor coil and 2 coupling coils for enabling a wireless measurement. The inductance of the sensor coil, which could be changed by applied current, causes the change of resonance frequency of the resonance circuit. A pair of magnet was attached to the ferrite core to apply a bias magnetic field that enabled the determination of the current direction. We obtained an output voltage change of 18 V with the current of -3~3 A. But, the output was nonlinear. In order to realize the non-contact current measuring method proposed in the present study, there is a need for a strict investigation of linearity and resolution for the future study.

Evaluating the Depth of a Surface-opening Crack in Concrete Slabs using Surface wave Measurements (표면파 측정을 통한 콘크리트 슬래브의 표면균열 깊이 측정)

  • Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.104-112
    • /
    • 2015
  • Non-contact surface wave transmission (SWT) measurements are used to evaluate the depth of a surface-breaking crack in concrete slabs. The author propose a measurement model that includes an appropriate configuration of the source and receivers, and a transmission function for the given configuration. A series of numerical simulations using a 3D finite element model is used to obtain the transmission function. Then, validity of a proposed model is verified through experimental studies. Two air-coupled sensors are used to measured surface waves across surface-breaking cracks with varying depths from 0mm to 100mm with intervals of 10mm in a concrete slab ($1500{\times}1500{\times}180mm^3$) in laboratory. As a result, the proposed method is demonstrated as to be effective for charactering the depth of a surface-breaking crack in concrete bridge deck with an average error of 10%. A discussion on practical applications of the proposed method is also included in this article.

Implementation of Non-contact Plant Growth Measurement System based on USN Technologies (USN 기술 기반의 비접촉 식물 생장 측정 시스템 구현)

  • Suk, Jin-Weon;Ryoo, In-Tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.137-145
    • /
    • 2010
  • This paper is proposed non-contact plant growth measurement system using infrared sensor based on USN(Ubiquitous Sensor Network) technologies. The proposed system has used noncontact sensors to reduce any potential damage when it measures the growth of the plant. In this system, plant growth parameters such as diameter, cross-sectional area and thickening form are measured in real-time non-contact method. The measured data are transmitted to remote server by using sensor network technologies, stored and analyzed at the server, and the analyzed data are finally provided for users. In this paper, the proposed plant growth measurement system has been designed and implemented using non-contact infrared sensor based measurement methods and devices, and its performances have been verified by actual measurement experiments at the fields.

2중파장 영사식 무아레의 N-Buckets 알고리즘 오차비교에 관한 실험적 연구

  • 유원재;박낙규;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.181-181
    • /
    • 2004
  • 3 차원 형상측정기술(3-D Profile Measurement Method)은 가공품의 치수검사 및 형상측정 등의 공학분야뿐만 아니라 최근에는 의류산업 및 의학산업은 물론 오락산업의 가상현실 구현 등 여러 분야로 점차 사용이 확대되고 있다. 이러한 요구를 만족시킬 수 있는 광학을 바탕으로 한 비접촉 3 차원 형상측정방법(Non-contacting 3-D Profile Measuring Method)은 고속, 고정밀도 측정이 가능하기 때문에 활발히 연구되고 있다. 광학을 이용한 대표적인 3 차원 비접촉 측정방법의 하나인 영사식 무아레는 그림자식 무아레의 단점인 격자의 크기가 측정물체보다 커야 한다는 점과 측정물체와 격자사이의 거리 제한 문제를 해결하였으며, 위상이동법을 사용함으로서, 무아레 무늬 형태의 영향을 받지 않고 측정이 가능해졌다.(중략)

  • PDF

Clinical Evaluation of a Rebound Tonometer in Patients Who Underwent Penetrating Keratoplasty (전층각막이식을 시행한 안에서 리바운드 안압계의 임상적 유용성)

  • Kim, Jong Woo;Jung, Ji Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1122-1128
    • /
    • 2018
  • Purpose: To compare the measurements of the rebound tonometer (RT), Goldmann applanation tonometer (GAT) and noncontact tonometer (NCT) in patients who underwent penetrating keratoplasty (PKP), and to evaluate the reproducibility of the RT measurements. Methods: This study included 19 PKP eyes and 28 normal eyes. We compared the intraocular pressure (IOP) measurements of the GAT and NCT with the RT in both groups using Spearman's correlation analysis and the Wilcoxon signed-rank test. The IOP, as measured with an RT in each group, was assessed with respect to reproducibility using the intraclass correlation coefficient (ICC). Results: In normal eyes, there was no significant difference in the measurements obtained with the RT, GAT, and NCT (p > 0.050). In the patient group, the RT measurements were not significantly different from those of the GAT (p = 0.872), but they were significantly lower than those obtained with the NCT (p = 0.011). However, the RT measurements showed a relatively high correlation with those of the GAT and NCT (r = 0.770 and 0.879, respectively). The ICC of the RT was 0.986 for the PKP eye group and 0.961 for the normal eye group, both of which were highly reproducible. Conclusions: In PKP eyes, the measurements obtained with the RT showed a relatively high correlation with those of the GAT and NCT, and the repeatability of the RT measurements was high and similar to those for normal eyes. The RT can therefore be considered a useful method for measuring the IOP in PKP eyes.

CANFLEX 연료봉 다발의 수중 진동특성

  • 박진석;정장환;김복득
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.921-926
    • /
    • 1998
  • CANFLEX 연료봉 다발의 3000 시간 내구성 시험 기간 동안 속도센서를 사용하여 압력관 내부에 장전된 연료봉 다발의 진동을 측정하였다. 압력관 내부에 장전된 연료봉의 진동측정은 고온, 고압, 그리고 공간적 제약 때문에 가속도계나 스트레인 게이지 같은 접촉센서로는 측정할 수 없다. 비접촉 센서를 사용하면 이러한 난점을 해결하고 압력관 내부에 장전된 연료봉 다발의 진동을 측정할 수 있다. 속도센서는 비접촉 센서로서 가우스(gauss)의 크기를 감지하여 전압을 출력하는 센서이지만, 측정거리, 주파수, 그리고 속도와 가우스가 비선형이기 때문에 교정을 한 후에 사용하여야 한다. 본 본문에는 속도센서의 교정방법과 압력관 내부에 고온, 고압의 유체가 흐를 때 발생하는 연료봉 다발의 진동특성을 구하였다.

  • PDF

Measurement of Hairiness and Analysis of Surface Roughness by Using Non-contact Method for Fabrics (직물의 잔털량과 잔털수의 측정과 비접촉 표면 거칠기 분석)

  • 권영하
    • Science of Emotion and Sensibility
    • /
    • v.3 no.2
    • /
    • pp.9-15
    • /
    • 2000
  • 직물 표면을 문지를 때 느끼는 촉감은 여러 가지 기계적인 자극이 손 끝에 전달되어 느끼게 되므로, 직물의 표면의 특성을 분석하는 것은 매우 중요하다. 그러므로 표면을 덮고 있는 잔털의 양과 숫자를 측정하는 방법을 개발하고 촉감해석에 사용할 수 있도록 하였다. 표면의 거칠기는 비접촉으로 측정하여 잔털의 성질까지 포함된 스펙트럼을 얻었으며 FFT 분석을 통해 직물의 표면 구조의 특징과 상관되는 결과를 확인하였다. KES-F System에서 측정한 Hand Value와 비교 분석한 결과, 표면 거칠기와 잔털량과 잔털수는 객관적인 촉감해석에 중요한 요소로 사용할 수 있었다.

  • PDF