• Title/Summary/Keyword: 비잡음 화소

Search Result 120, Processing Time 0.033 seconds

An Edge Detection for Face Feature Extraction using λ-Fuzzy Measure (λ-퍼지척도를 이용한 얼굴특징의 윤곽선 검출)

  • Park, In-Kue;Ahn, Bo-Hyeok;Choi, Gyoo-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.75-79
    • /
    • 2009
  • In this paper the method was proposed which uses ${\lambda}$-fuzzy measure to detect the edge of the features of the face region. In the conventional method the features was founded using valley, brightness and edge. This method had its drawbacks that it is so sensitive to the external noises and environments. This paper proposed ${\lambda}$-fuzzy measure to cope with this drawbacks. By considering each weight of the pixels the integral evaluation was considered using the center of area method. Thus the continuity of the edge was kept by way of the neighborhood information and the reduction of time complexity wad resulted in.

  • PDF

위성 영상 탑재체에 관련된 영상품질 인자의 특성

  • Cho, Young-Min
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.66-74
    • /
    • 2002
  • The characteristics of the satellite image quality parameters driven by satellite imaging instrument are investigated. Since the satellite image is directly produced by the satellite imaging instrument, the satellite image quality depends on the imager performance highly. This is why the imager performance parameters are considered as an important part of the satellite image quality parameters. The imager performance parameters consist of spectral band parameters, ground sample distance(GSD) parameters, swath width parameters, imager Modulation Transfer Function (MTF), imager Signal to Noise Ratio(SNR), radiometric response characteristics parameters, pixel registration, and imager calibration.

  • PDF

A Study of Improving LDP Code Using Edge Directional Information (에지 방향 정보를 이용한 LDP 코드 개선에 관한 연구)

  • Lee, Tae Hwan;Cho, Young Tak;Ahn, Yong Hak;Chae, Ok Sam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.86-92
    • /
    • 2015
  • This study proposes new LDP code to improve facial expression recognition rate by including local directional number(LDN), edge magnitudes and differences of neighborhood edge intensity. LDP is less sensitive on the change of intensity and stronger about noise than LBP. But LDP is difficult to express the smooth area without changing of intensity and if background image has the similar pattern with a face, the facial expression recognition rate of LDP is low. Therefore, we make the LDP code has the local directional number and the edge strength and experiment the facial expression recognition rate of changed LDP code.

A Study on the Dyadic Sorting method for the Regularization in DT-MRI (Dyadic Sorting 방법을 이용한 DT-MRI Regularization에 관한 연구)

  • Kim, Tae-Hwan;Woo, Jong-Hyung;Lee, Hoon;Kim, Dong-Youn
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.4
    • /
    • pp.30-39
    • /
    • 2010
  • Since Diffusion tensor from Diffusion Tensor Magnetic Resonance Imaging(DT-MRI) is so sensitive to noise, the principle eigenvector(PEV) calculated from Diffusion tensor could be erroneous. Tractography obtained from PEV could be deviated from the real fiber tract. Therefore regularization process is needed to eliminate noise. In this paper, to reduce noise in DT-MRI measurements, the Dyadic Sorting(DS) method as regularization of the eigenvalue and the eigenvector is applied in the tractography. To resort the eigenvalues and the eignevectors, the DS method uses the intervoxel overlap function which can measure the overlap between eigenvalue-eigenvector pairs in the $3\times3$ pixel. In this paper, we applied the DS method to the three-dimensional volume. We discuss the error analysis and numerical study to the synthetic and the experimental data. As a result, we have shown that the DS method is more efficient than the median filtering methods as much as 79.97%~83.64%, 85.62%~87.76% in AAE, AFA respectively for the corticospinal tract of the experimental data.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Block-based Color Image Segmentation Using Cylindrical Metric (Cylindrical metric을 사용한 블록기반 컬러 영상 분할)

  • Nam Hyeyoung;Kim Boram;Kim Wookhyun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.3 s.303
    • /
    • pp.7-14
    • /
    • 2005
  • In this paper we proposed the block-based color image segmentation method using the cylindrical metric to solve the problems such as long processing time and over segmentation due to noise and texture properties in the conventional methods. In the proposed method we define the new similarity function and the merge condition between regions to merge initial regions with the same size considering the color and texture properties of chromatic and achromatic regions which is defined according to the HSI color values, and we continue to merge boundary blocks into the adjacent region already segmented to maintain edges until the size of block is one. In the simulation results the proposed method is better than the conventional methods in the evaluation of the segmented regions of texture and edge region, and we found that the processing time is decreased by factor of two in the proposed method.

Fuzzy-based Segmentation Algorithm for Brain Images (퍼지기반의 두뇌영상 영역분할 알고리듬)

  • Lee, Hyo-Jong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.102-107
    • /
    • 2009
  • As technology gets developed, medical equipments are also modernized and leading-edge systems, such as PACS become popular. Many scientists noticed importance of medical image processing technology. Technique of region segmentation is the first step of digital medical image processing. Segmentation technique helps doctors to find out abnormal symptoms early, such as tumors, edema, and necrotic tissue, and helps to diagnoses correctly. Segmentation of white matter, gray matter and CSF of a brain image is very crucial part. However, the segmentation is not easy due to ambiguous boundaries and inhomogeneous physical characteristics. The rate of incorrect segmentation is high because of these difficulties. Fuzzy-based segmentation algorithms are robust to even ambiguous boundaries. In this paper a modified Fuzzy-based segmentation algorithm is proposed to handle the noise of MR scanners. A proposed algorithm requires minimal computations of mean and variance of neighbor pixels to adjust a new neighbor list. With the addition of minimal compuation, the modified FCM(mFCM) lowers the rate of incorrect clustering below 30% approximately compared the traditional FCM.

Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement (FHD급 DIC 플랫폼의 변위계측용 영상품질 분석)

  • Park, Jongbae;Kang, Mingoo
    • Journal of Internet Computing and Services
    • /
    • v.19 no.1
    • /
    • pp.105-111
    • /
    • 2018
  • This paper presents the analysis of image quality with FHD(Full HD) resolution camera equipped DIC(Digital Image Correlation) platform for the measurement of the architectural structure's relative displacement. DIC platform was designed based on i.MX6 of Freescale. Displacement measurement based on DIC method, the error is affected by image quality factors as pixel number, brightness, contrast, and SNR[dB](Signal to Noise Ratio). The effect were analyzed. The displacement of ROI(Region Of Interest) area within the image was measured by sub-pixel units based on DIC method. The non-contact telemetry property of DIC method, it can be used to long distance non-contact measurement. The various displacement results was measured and analyzed with the image quality factor adjustment according to the distance(25m, 35m, 50m).

A Fast Motion Vector Search in Integer Pixel Unit for Variable Blocks Siz (가변 크기 블록에서 정수단위 화소 움직임 벡터의 빠른 검색)

  • 이융기;이영렬
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.388-396
    • /
    • 2003
  • In this paper, a fast motion search algorithm that performs motion search for variable blocks in integer pixel unit is proposed. The proposed method is based on the successive elimination algorithm (SEA) using sum norms to find the best estimate of motion vector and obtains the best estimate of the motion vectors of blocks, including 16${\times}$8, 8${\times}$16, and 8${\times}$8, by searching eight pixels around the best motion vector of 16${\times}$16 block obtained from all candidates. And the motion vectors of blocks, including 8${\times}$4, 4${\times}$8, and 4${\times}$4, is obtained by searching eight pixels around the best motion vector of 8${\times}$8 block. The proposed motion search is applied to the H.264 encoder that performs variable blocks motion estimation (ME). In terms of computational complexity, the proposed search algorithm for motion estimation (ME) calculates motion vectors in about 23.8 times speed compared with the spiral full search without early termination and 4.6 times speed compared with the motion estimation method using hierarchical sum of absolute difference (SAD) of 4${\times}$4 blocks, while it shows 0.1dB∼0.4dB peak signal-to-noise ratio (PSNR) drop in comparison to the spiral full search.

A study on Object Contour Detection using improved Dual Active Contour Model (개선된 Dual Active Contour Model을 이용한 물체 윤곽선 검출에 관한 연구)

  • 문창수;유봉길;이웅기
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.1
    • /
    • pp.81-94
    • /
    • 1998
  • In order to extract the contour of interesting object in the image, Kass suggested the Active Contour Model called "Snakes". Snakes is a model which defines the contour of image energy. It also can find the contour of object by minimizing these energy functions. The speed of this model is slow and this model is sensitive of initialization. In order to improve these problems, Gunn extracted the accurate contour by using two initialization. and operated to less sensitive of initialization. This method could extract more accurate contour than the existing method, but it had no effect in the speed and it was sensitive of noise. This paper applied to the Energy Minimization Algorithm about only the pixel within the window applying the window of 8$\times$8 size at each contour point consisting Snakes in order to solve these problems. The method offered in this paper is applied to extract the contour of original image and cup image added to gaussian noise. By tracking the face using this offered method, it is applied to virtual reality and motion tracking. tracking.

  • PDF