• Title/Summary/Keyword: 비선형 응답

Search Result 760, Processing Time 0.023 seconds

Evaluation of Seismic Performance of Mixed Building Structures by using the Nonlinear Displacement Mode Method (비선형 변위모드법을 적용한 복합구조물의 내진성능평가)

  • 김부식;송호산
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.71-80
    • /
    • 2003
  • Though a nonlinear time history analysis may be provided to estimate more exactly the seismic performance of building structure, approximation methods are still needed in the aspect of practicality and simplicity, In converting a multi-story structure to an equivalent SDOF system, the mode vectors of the multi-story structure are assumed as the mode shape in elastic state regardless of elastic or elastic-plastic state. However, the characteristics of displacement mode are also changed after the yielding made in the structural elements, because the structure becomes inelastic in each incremental load step. In this research, a method of converting MDOF system to ESDOF system is presented by using nonlinear displacement mode considering the mode change of structures after the yielding. Also, the accuracy and efficiency of the method of the nonlinear displacement mode method of the estimate of seismic response of Mixed Building Structures were examined by comparing the displacements of the roof level of the multi-story building structures estimated from this converted displacement response of ESDOF with the displacement of the roof level through the nonlinear dynamic analysis of the multi-story building structures subjected to an actual earthquake excitation.

화련 대형내진모델시험 구조물의 지진응답해석

  • 현창헌;이성규;윤철호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.471-476
    • /
    • 1997
  • 본 논문에서는 국제공동연구로 수행중인 화련 대형내진모델시험 사업에서 계측지진기록을 이용한 모델구조물의 지진응답해석을 수행한 결과를 기술하였다. 지진응답해석은 3차원 유연체적 부구조법을 사용하는 지반-구조물 상호작용해석 전용 전산프로그램인 SASSI를 이용하여 수행하였으며, 지반 특성은 지반조사 결과 제시된 두 가지 지반모델과 계측지진 지반운동으로부터 직접 유도해 낸 지반모델의 지반 특성값을 사용하였다. 또한 본 연구에서는 지반과 구조물 특성값의 변화에 대한 구조물 지진응답의 민감도 및 지반의 비선형 특성이 구조물의 응답에 미치는 영향을 분석하였다.

  • PDF

Effect of Nonlinear Analysis Procedures for Seismic Responses of Reinforced Concrete Wall Structure (철근콘크리트 벽체구조물의 지진응답에 대한 비선형 해석기법의 영향)

  • Song, Jong-Keol;Jang, Dong-Hui;Chung, Yeong-Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.659-675
    • /
    • 2006
  • Recently, significant progress has been made in performance-based engineering methods that rely mainly on nonlinear static seismic analysis procedures. The Capacity Spectrum Method (CSM) and the Displacement Coefficient Method (DCM) are the representative nonlinear static seismic analysis procedures. In order to evaluate the applicability of the procedures to the seismic evaluation and design process of new and existing structures, the accuracy of both CSM and DCM should be evaluated in advance. The accuracy of seismic responses by the nonlinear static procedures is evaluated in comparison with the shaking table test results for the structural wall specimen subjected to the far field and near field earthquakes. Also conducted are comparative studies where the shaking table test results are compared with those from nonlinear dynamic analysis procedures, i.e., Single-Degree-of-Freedom (SDOF), equivalent SDOF and Multi-Degree-of-Freedom (MDOF) systems.

CCD Non-uniformity Correction Method based on Pixel Non-Linearity Model (픽셀 비선형성 모델을 기반으로 한 영상센서 불균일 특성 보정)

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • All pixels of image sensor do not react uniformly when the light of same radiance enters into the camera. This non-uniformity has a direct influence on the image quality. However we can overcome it by calibration process under the special test-setup. Usually it is used the algorithm to get the correction coefficients under the specific illumination condition. But, this method has drawback in the very low or very high illumination due to pixel non-linearity. This paper describes the robust algorithm, which calculates the correction coefficients based on the pixel non-linearity model, against thew hole radiance. The paper shows the non-uniformity test results with the own camera and the specified test equipments as well. The results shows the best performance over the entire radiance when this method is applied.

Nonlinear Seismic Analysis of Steel Buildings Considering the Stiffnesses of the Foundation-Soil System (기초지반강성을 고려한 철골 건축구조물의 비선형 지진해석)

  • Oh, Yeong Hui;Kim, Yong Seok
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.173-180
    • /
    • 2006
  • The seismic responses of a building are affected by the base soil conditions. In this study, linear time-history seismic analysis and nonlinear pushover static seismic analysis were performed to estimate the base shear forces of 3-, 5-, and 7-story steel buildings, considering the rigid and soft soil conditions. Foundation soil stiffness, based on the equivalent static stiffness formula, is used for the damper, one of the Link elements in SAP 2000. The base shear forces of the steel buildings, estimated through time-history analysis using the general-purpose structural-analysis program of SAP 2000, were compared with those calculated using the domestic seismic design code, the UBC-97 design response spectrum. and pushover static nonlinear analysis. The steel buildings designed for gravity and wind loads showed elastic responses with a moderate earthquake of 0.11 g, while the elastic soft-soil layer increased the displacement and the base shear force of the buildings due to soil-structure interaction and soil amplification. Therefore, considering the characteristics of the soft-soil layer, it is more reasonable to perform an elastic seismic analysis of a building's structure during weak or moderate earthquakes.

A Modification Technique of Finite Element Model for Dynamic Analysis under Multiple Support Excitations (다지지점 가진에 대한 동적해석을 위한 유한요소모형의 수정기법)

  • 김재민
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.3
    • /
    • pp.437-445
    • /
    • 1999
  • This paper presents a simple modification technique of finite element model for dynamic analysis of linear/nonlinear structural system subjected to multiple support excitation. For the sake of verification of the proposed method, dynamic responses obtained by the present technique for a couple of linear and nonlinear structural systems were compared with those by a general-purpose structural analysis software which can deal with the multi-support analysis. The method presented in this paper is expected to be used for multiple support excitation analysis by means of a computer code without the capability of modeling the non-synchronous support motion.

  • PDF

Nonlinear Acoustic-Pressure Responses of H2/Air Counterflow Diffusion Flames (수소/공기 대향류 확산화염의 비선형 음향파 응답특성에 관한 연구)

  • Kim, Hong-Jip;Chung, Suk-Ho;Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1158-1164
    • /
    • 2003
  • Steady-state structure and acoustic-pressure responses of $H_2$/Air counterflow diffusion flames are studied numerically with a detailed chemistry in view of acoustic instability. The Rayleigh criterion is adopted to judge acoustic amplification or attenuation from flame responses. Steady-state flame structures are first investigated and flame responses to various acoustic-pressure oscillations are numerically calculated in near-equilibrium and near-extinction regimes. The acoustic responses of $H_2$/Air flame show that the responses in near-extinction regime always contribute to acoustic amplification regardless of acoustic-oscillation frequency Flames near extinction condition are sensitive to pressure perturbation and thereby peculiar nonlinear responses occur, which could be a possible mechanism in generating the threshold phenomena observed in combustion chamber of propulsion systems.

Seismic Retrofit of Steel Framed Structures Using VE Damper Model Considering Its Physical and Mechanical Characteristics (물리.역학적 특성을 고려한 점탄성 감쇠기 모델에 의한 강뼈대구조물의 지진응답개선)

  • 조창근;박문호;곽진순
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.2
    • /
    • pp.225-235
    • /
    • 2001
  • 본 연구는 물리·역학적 특성을 고려한 점탄성 감쇠기의 수치모델에 의한 강뼈대구조물의 지진응답개선에 관해서 조사하고자 한다. 온도변화에 의한 감쇠기 이력거동에 미치는 영향을 고려하기 위하여, 점탄성 감쇠기의 모델은 온도-주기 등가원리와 더불어 개선된 분수도함수법에 기초하여 정식화하였다. 본 감쇠기 모델의 알고리즘을 일반화된 강뼈대구조물의 비선형 동적 해석 프로그램에 추가하였다. 강뼈대구조물에 대한 해석 예를 통하여, 제시된 모델에 의한 점탄성 감쇠기의 지진응답개선에 관한 효과를 확인할 수 있었다.

  • PDF

An Analysis of Forced Vibration Response of a Cantilever Beam with a Dry Friction Damper (건마찰 감쇠기가 부착된 외팔보의 강제진동 응답 해석)

  • Go, Young-Jun;Kang, Byoung-Yong;Chang, Ho-Gyeong;Kim, Ye-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.33-39
    • /
    • 1996
  • A theoretical study of the forced vibration response of a cantilevered beam with non-linear dry friction damping is analyzed by various slip displacements and force levels for the position coordinates of spring-mass-damper and external exciting force. A component mode analysis is carried out based on the constraint conditions and Lagrange multipliers to treat physical systems with non-linear damping. The analysis has shown that the basic phenomena observed for a simply supported beam with a dry friction damper attached are also observed for cantilevered beam.

  • PDF

Optimal design of nonlinear damping system for seismically-excited adjacent structures using multi-objective genetic algorithm integrated with stochastic linearization method (추계학적 선형화 방법 및 다목적 유전자 알고리즘을 이용한 지진하중을 받는 인접 구조물에 대한 비선형 감쇠시스템의 최적 설계)

  • Ok, Seung-Yong;Song, Jun-Ho;Koh, Hyun-Moo;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.1-14
    • /
    • 2007
  • Optimal design method of nonlinear damping system for seismic response control of adjacent structures is studied in this paper. The objective functions of the optimal design are defined by structural response and total amount of the dampers. In order to obtain a solution minimizing two mutually conflicting objective functions simultaneously, multi-objective optimization technique based on genetic algorithm is adopted. In addition, stochastic linearization method is embedded into the multi-objective framework to efficiently estimate the seismic responses of the adjacent structures interconnected by nonlinear hysteretic dampers without performing nonlinear time-history analyses. As a numerical example to demonstrate the effectiveness of the proposed technique, 20-story and 10-story buildings are considered and MR dampers of which hysteretic behaviors vary with the magnitude of the input voltage are considered as nonlinear hysteretic damper interconnecting two adjacent buildings. The proposed approach can provide the optimal number and capacities of the MR dampers, which turned out to be more economical than the uniform distribution system while maintaining similar control performance. The proposed damper system is verified to show more stable performance in terms of the pounding probability between two adjacent buildings. The applicability of the proposed method to the design problem for optimally placing semi-active control system is examined as well.