• Title/Summary/Keyword: 비모수검정

Search Result 121, Processing Time 0.027 seconds

3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle (3T MR 스핀에코 T1강조영상에서 적정의 숙임각)

  • Bae, Sung-Jin;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). Materials and Method : T1-weighted images of the cerebrum of brain were obtained from 50$^\circ$ to 130$^\circ$ FA with 10$^\circ$ interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp ($\frac{-TR}{T1}$) and Ernst angle cos $\theta$ = exp ($\frac{-TR}{T1}$). Results : The SNR of WM at 130$^\circ$ FA is approximately 1.6 times higher than the SNR of WM at 50$^\circ$. The SNR of GM at 130$^\circ$ FA is approximately 1.9 times higher than the SNR of GM at 50$^\circ$. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120$^\circ$ FA, the SNR of GM started decreasing at less than 110$^\circ$. The highest SNRs of WM and GM were obtained at 130$^\circ$ FA. The highest CNRs, however, were obtained at 80$^\circ$ FA. Conclusion : Although SNR increased with the change of FA values from 50$^\circ$ to 130$^\circ$ at 3T SE T1WI, CNR was higher at 80$^\circ$ FA than at the usually used 90$^\circ$ FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  • PDF

Clinical outcomes of implant supported fixed-hybrid prostheses in the fully edentulous arches (완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kwon, Min-Jung;Kim, Young-Kyun;Cha, Min-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.183-189
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate clinical outcomes of implant supported fixed-hybrid prostheses (FHP) in the fully edentulous arches. Materials and methods: Patients in this retrospective study were restored with fixed-hybrid prostheses supported by 4 to 6 implants and functioned more than 1 year of loading. Outcome measures were marginal bone change of implant related with sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients, tilting of posterior implant by Mann- Whitney U test and cantilever length of superstructure by regression analysis, and complication rates. Significance level was set P<.05. Results: A total number of 84 implants (16 restorations) placed in 16 patients were observed for 28 months and mean marginal bone loss was $0.53{\pm}0.39mm$. There were no differences of marginal bone loss according to sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients (P>.05), and cantilever length was not significantly related with a marginal bone loss of implant next to cantilever (P>.05). Complication was shown in 11 patients and veneer fracture and dislodging of artificial teeth were most prevalent. Conclusion: Within the limitations of this study, although marginal bone loss of FHP was very little, complication rates were high. Irrespective of tilting of most posterior implants, marginal bone loss of most posterior implants next to cantilever was less than those of the other implants positioned anteriorly. Cantilever length (<17 mm) did not affect a marginal bone loss of most posterior implants.

The Rsearch Trends of Papers in the Journal of Dental Hygiene Science (한국치위생과학회지 게재논문의 연구경향 분석)

  • Lee, Sun-Mi;Ahn, Se-Youn;Han, Hwa-Jin;Han, Ji-Youn;Lee, Chun-Sun;Kim, Chang-Hee
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.67-73
    • /
    • 2014
  • This study analyzed 548 pieces of these, which were reported in the Journal of Dental Hygiene Science of having been published from 2001 to Vol. 12, No. 6 in 2012. In conclusion, as for analysis of research design, first, it was the largest in cross sectional research. Second, the research subjects of survey theses were higher in order of dental hygienist and dental hygiene student. Third, number of thesis authors was the largest in order of two persons and three persons. Fourth, statistical method was in order of descriptive statistics, t-test, and ANOVA. Research theme was in order of dental health behavioral science and clinical dental hygiene. Fifth, as for research-expense benefit, only 17.7% was supported research funds. As a result of this study, there should be a research on thesis of diverse designs in the future. There is a need of being performed actively a research on alienated classer or special subjects as well as a research on activity related to dental hygiene.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

The color stability and antibacterial of provisional polyethyl methacrylate (PEMA) resin with zirconia nanoparticles (지르코니아 나노입자 첨가된 PEMA (Polyethyl Methacrylate)레진 표면의 색안정성 및 항균평가)

  • Kim, Hee-Seon;Lee, Seon-Ki;Jang, Woohyung;Park, Chan;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.18-25
    • /
    • 2022
  • Purpose: This study aimed to evaluate the color stability and antibacterial properties of the surface of polyethyl methacrylate (PEMA) resin with zirconia nanoparticles added. Materials and Methods: The control group was pure PEMA resin, and the experiment group was PEMA resin 15 mm in diameter and 2.5 mm in thickness disk-shaped specimens with 2, 4 and 8 w/v% of zirconia nanoparticles added, which were respectively divided into Group Z2, Group Z4, and Group Z8. After analyzing the surface roughness and color stability of the specimens, their antibacterial properties were evaluated using Porphyromonas gingivalis (P. gingivalis). The Statistical analysis was performed using when normality was met in the Shapiro-Wilk test, one-way ANOVA was used to test parameters, and Tukey's test was used as a post hoc test. When normality was not met, the Kruskal-Wallis test, a non-parametric test was used (P < 0.05). Results: The surface roughness measurement found that there was no significant difference between the experimental and control groups. The color stability evaluation showed that the Z2, Z4, and Z8 groups were within the color range of natural teeth. The adhesion of P. gingivalis was evaluated to be significantly reduced in Group Z2 compared to the control group (P < 0.05). In the Z2 group, Z4 group, and Z8 group, dead cells bacteria than the control group were observed. Conclusion: In conclusion, PEMA resin with zirconia nanoparticles added was within the range of natural teeth in color and reduced the adhesion of P. gingivalis.

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Comparison of longitudinal treatment effects with facemask and chincup therapy followed by fixed orthodontic treatment on Class III malocclusion (상악전방견인장치와 이모장치 및 고정식 교정장치 치료를 받은 III급 부정교합 환자의 치료효과에 대한 종단적 비교)

  • Lee, Nam-Ki;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.362-371
    • /
    • 2009
  • Objective: The purpose of this study was to compare the longitudinal treatment effects of facemask with rapid maxillary expansion (FM/RME) and chincup (CC) therapy followed by fixed orthodontic treatment (FOT) in Class III malocclusion (CIII) patients. Methods: The samples consisted of twenty-one CIII patients who had similar skeletal and dental characteristics before FM/RME or CC therapy and good retention results (Class I molar/canine relationship and positive overbite/overjet) after FOT (Group 1, FM/RME, n = 11; Group 2, CC, n = 10). Lateral cephalograms were taken before (T0) and after FM/RME or CC therapy (T1), and after FOT and retention (T2). Skeletal and dental variables were measured. Mann-Whitney U-test and Wilcoxon signed-rank test were used for statistical analysis. Results: During T0-T1, FM/RME therapy induced forward movement of point A, and labioversion of the upper incisors. Both groups showed posterior repositioning of the mandible. FM/RME resulted in increase of the vertical dimension; however, CC caused an increase in articular angle and decrease in gonial angle. During T1-T2, both groups exhibited forward growth of point A. Group 1 showed forward growth and counterclockwise rotation of the mandible and increase of IMPA; however, Group 2, showed increase of ANS-Me/N-Me and decrease of overbite. Conclusions: The key factor for successful FM/RME and CC therapy and good retention results might be a harmonized forward growth of the maxilla that could keep pace with the growth and rotation of the mandible.

Assessment of statistical errors of articles published in the Journal of the Korean Academy of Prosthodontics: 2006 - 2010 (대한치과보철학회지에서 볼 수 있는 통계적 오류의 고찰(2006 - 2010))

  • Kang, Dong-Wan;Seo, Yunam;Oh, Nam-Sik;Lim, Hoi-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.258-270
    • /
    • 2012
  • Purpose: Use of inappropriate statistical methods may lead to incorrect conclusions and a waste of valuable resources. The goal of this study was to assess the frequency and the types of several common statistical errors in the published articles of the Journal of the Korean Academy of Prosthodontics (JKAP) for a 5-year period. Materials and methods: Of 336 articles in the JKAP published from 2006 to 2010, 255 articles using statistics were reviewed and classified by statistical method and year. The frequency and types of the statistical methods were examined, and the statistical errors were evaluated by the appropriateness of the experimental design, assumption check, independent outcomes, proper sample size and suitable use of statistical method. Statistical guidelines were completed based on the appropriateness. Results: Of the 255 articles using statistics, 193 articles (75.9%) used inferential statistics and 153 articles used SPSS statistical software (60.0%). Of the articles using inferential statistics, the three most frequently used statistical methods were ANOVA (41.5%), t-test (20.0%), and the nonparametric method (16.9%). The average rate of statistical errors was 61.2 percent, similar to the rate reported by several studies completed for the medical journal. Conclusion: After the whole analysis of the difference among the groups, post-hoc tests for the pairwise comparisons are required. The optimal sample size calculation is an essential part of this study protocol. To minimize the occurrence of statistical errors, statistical guidelines were developed according to each statistical test procedure and will contribute to the academic improvement in the JKAP.

Analysis of the Seasonal Concentration Differences of Particulate Matter According to Land Cover of Seoul - Focusing on Forest and Urbanized Area - (서울시 토지피복에 따른 계절별 미세먼지 농도 차이 분석 - 산림과 시가화지역을 중심으로 -)

  • Choi, Tae-Young;Moon, Ho-Gyeong;Kang, Da-In;Cha, Jae-Gyu
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.635-646
    • /
    • 2018
  • This study sought to identify the characteristics of seasonal concentration differences of particulate matter influenced by land cover types associated with particulate matter emission and reductions, namely forest and urbanized regions. PM10 and PM2.5 was measured with quantitative concentration in 2016 on 23 urban air monitoring stations in Seoul, classified the stations into 3 groups based on the ratio of urbanized and forest land covers within a range of 3km around station, and analysed the differences in particulate matter concentration by season. The center values for the urbanized and forest land covers by group were 53.4% and 34.6% in Group A, 61.8% and 16.5% in Group B, and 76.3% and 6.7% in Group C. The group-specific concentration of PM10 and PM2.5 by season indicated that the concentration of Group A, with high ratio of forests, was the lowest in all seasons, and the concentration of Group C, with high ratio of urbanized regions, had the highest concentration from spring to autumn. These inter-group differences were statistically significant. The concentration of Group C was lower than Group B in the winter; however, the differences between Groups B to C in the winter were not statistically significant. Group A concentration compared to the high-concentration groups by season was lower by 8.5%, 11.2%, 8.0%, 6.8% for PM10 in the order of spring, summer, autumn and winter, and 3.5%, 10.0%, 4.1% and 3.3% for PM2.5. The inter-group concentration differences for both PM10 and PM2.5 were the highest in the summer and grew smaller in the winter, this was thought to be because the forests' ability to reduce particulate matter emissions was the most pronounced during the summer and the least pronounced during the winter. The influence of urbanized areas on particulate matter concentration was lower compared to the influence of forests. This study provided evidence that the particulate matter concentration was lower for regions with higher ratios of forests, and subsequent studies are required to identify the role of green space to manage particulate matter concentration in cities.