구형 간극에서의 임계출력에 관한 상관식 검증 및 보완 (Correlation Verification and Revision of Critical Power in a Hemispherical Narrow Gap)

  • 하광순;박래준;김상백;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.411-414
    • /
    • 2002
  • The CHFG(Critical Heat Flux in Cap) test results have been evaluated to quantify the critical powers in hemispherical narrow gaps and Park's correlation has been verified. For verification of the Park's correlation, the critical powers in hemispherical narrow gaps have been measured using water at a pressure of 0.1-0.3 WPa for the hemispherical gap thickness of 1.0mm, and the heated top diameter of 238mm The measured critical powers were compared with Park's and Monde's correlation. As a results, the Park's correlation was most accurate of other correlations, however, estimated the critical powers somewhat larger than measured ones. So, it was suggested that the diameter factor in Park's correlation should be revised.

  • PDF

高溫表面의 冷却時 再水着 溫度 에 관한 硏究 (A Study of Rewetting Temperature in Cooling of Hot Surfaces)

  • 정문기;이영환;박종석
    • 대한기계학회논문집
    • /
    • 제9권4호
    • /
    • pp.463-470
    • /
    • 1985
  • 본 논문에서는 가열관을 이용한 실험과 고온표면위에 놓인 물방울의 증발실험 을 통하여 재수착온도에 미치는 영향인자들을 분석하였으며, 이러한 분석결과를 토대 로 재수착온도상관식을 제시하였다.

미소 사각 채널에서의 마찰 압력 강하 (Pressure Drop due to Friction in Small Rectangular Channel)

  • 임태우;최재혁;김준효;최용석
    • 해양환경안전학회지
    • /
    • 제18권5호
    • /
    • pp.461-467
    • /
    • 2012
  • $500{\mu}m$의 수력직경을 가진 마이크로 채널에서 유동 비등 시 물에 대한 마찰 압력 강하를 측정하기 위한 실험적 연구를 수행하였다. 실험은 열 유속 $100-400kW/m^2$, 증기건도 0-0.2 그리고 질량 유속 $200-600kg/m^2s$의 범위에서 이루어졌다. 유동 비등 시 마찰 압력 강하는 두 가지 모델을 사용하여 예측된다. 즉, 두 상의 속도가 동일하다고 가정한 균질 모델과 두 상 사이에 서로 다른 속도를 가지는 분리류 모델로 분류된다. 실험결과 이상 마찰 승수는 질량 유속이 증가함에 따라 감소한다는 것을 알 수 있었다. 측정된 압력 강하 데이터는 매크로 스케일과 미니/마이크로 스케일에서 제안된 기존의 여러 상관식들과 비교하였다. 균질 모델은 본 연구에서 고려한 실험 조건에서 29.4 %의 평균 오차내에서 마찰 압력 강하를 예측하였다.

R-410A 비등열전달에 미치는 미세관경의 영향 (Effect on Flow Boiling Heat Transfer of Minichannel Diameter for R-410A)

  • 최광일;;오종택;;박창용
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.663-670
    • /
    • 2009
  • Two-phase flow boiling heat transfer of R-410A in horizontal small tubes was reported in the present experimental study. The local heat transfer coefficients were obtained over a heat flux range of 5 to 40 kW/$m^2$ a mass flux range of 170 to 600 kg/$m^2s$, a saturation temperature range of 3 to $10^{\circ}C$, and quality up to 1.0. The test section was made of stainless steel tubes with inner diameters of 0.5 and 3.0 mm, and lengths of 330 and 3000 mm, respectively. The test section was heated uniformly by applying a direct electric current to the tubes. The effects on heat transfer of mass flux, heat flux, inner tube diameter, and saturation temperature were presented. The experimental heat transfer coefficients are compared with six existing heat transfer coefficient correlations. A new boiling heat transfer coefficients correlation based on the superposition model for R-410A in small tubes was developed with mean deviation of 10.13%.

수평미세관내 NH3 비등열전달 특성 (Boiling Heat Transfer of Ammonia inside Horizontal Smooth Small Tube)

  • 최광일;오종택
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.101-108
    • /
    • 2013
  • This paper is presented an experimental study of flow boiling heat transfer characteristics of ammonia, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal small tube with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method is applied for supplying heat to the refrigerant, where the test tube is uniformly heated by electric current. The local heat transfer coefficients were obtained over a heat flux range of 20 to $80kW/m^2$, a mass flux range of 50 to $500kg/m^2s$, a saturation temperature range of 0 to $10^{\circ}C$, and quality up to 1.0. The pressure drops increase with increasing mass flux and heat flux, and with decreasing saturation temperature. The heat transfer coefficients increase with increasing mass flux and saturation temperature in middle and high quality region. And the local heat transfer coefficient increase with increasing heat flux in low quality region. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. A new boiling heat transfer coefficient correlation based on the superposition model for ammonia in small tubes is developed average deviation of -0.17% and mean deviation of 10.85%.

수평미세관내 R-290의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-290 in Horizontal Smooth Minichannel)

  • 최광일;;오종택
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.906-914
    • /
    • 2006
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of R-290. Pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel were obtained with inner tube diameter of 3.0 mm and length of 2,000 mm. The direct electric heating method was applied for supplying a heat to the refrigerant uniformly. The experiments were conducted with R-290 purity of 99.99%, at saturation temperature of 0 to $10^{\circ}C$, a mass flux range of $50{\sim}250kg/m^2s$, and a heat flux range of $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increased with increasing mass flux and saturation temperature, wherein the effect of mass flux was higher than that of the saturation temperature. Heat flux has a low effect on the increasing of heat transfer coefficient. The heat transfer coefficient was compared with six existing heat transfer coefficient correlations. The Zhang et al.'s correlation (2004) gave the best prediction of heat transfer coefficient. A new correlation to predict the two-phase flow heat transfer coefficient was developed based on the Chen correlation. The new correlation predicted the experimental data well with a mean deviation of 11.78% and average deviation of -0.07%.

대체냉매를 적용한 대형 압축식 냉동기의 만액식 증발기에 대한 성능 해석 (Performance Analysis of the Flooded Refrigerant Evaporators for Large Tonnage Compression-Type Refrigerators Using Alternative Refrigerants)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.18-25
    • /
    • 2016
  • 대형 압축식 냉동기의 증발기 전열관으로는 그간 평활관이 주로 사용되어 왔으나 최근들어 비등 성능이 우수한 성형 가공관을 많이 사용하고 있다. 증발기는 관군으로 구성되고 따라서 증발기 내 위치에 따라 냉매 상태가 다르다. 특히 R-11, R-123과 같은 저압 냉매는 압력변화에 따른 포화온도 변화가 크므로 위치에 따라 포화온도가 다르게 된다. 따라서 증발기를 적절히 설계하려면 증발기 내 각 위치에서의 냉매의 상태를 적절히 예측하여야 한다. 본 연구에서는 대형 냉동기의 만액식 증발기를 모사할 수 있는 컴퓨터 프로그램을 개발하였다. 이 프로그램은 증발기를 미소 체적으로 구분하고 각 미소 체적에 적절한 관 내외측 열전달 및 압력손실 상관식을 적용하여 해석을 수행하였다. 본 프로그램을 R-123을 사용하는 T사의 만액식 증발기 해석에 적용한 결과 만족할 만한 결과를 얻었다. 이 프로그램을 이용하여 신 냉매인 R-123, R-134a를 사용하는 만액식 증발기의 해석을 수행하였고 특히 관군 세장비의 영향을 검토하였다.

낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution)

  • 김내현
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.591-598
    • /
    • 2015
  • 본 연구에서는 핀 핏치와 핀 높이가 다른 7종류의 낮은 핀관에 대하여 LiBr 농도 0%.~50%, 열유속 $20kW/m^2{\sim}40kW/m^2$, 포화압력 7.38kPa~101.3kPa에서 풀 비등 실험을 수행하였다. 실험 범위에서 최적 낮은 핀관 형상은 핀 핏치 26fpi, 핀 높이 1.8mm로 나타났다. 핀 핏치가 너무 넓으면 전열 면적이 감소하고 핀 핏치가 너무 좁으면 기포의 성장 및 이탈이 원활하지 못하게 되어 최적 핀 핏치가 존재한다. 포화압력이 낮아질수록, LiBr 농도가 증가할수록 열전달계수는 감소하였다. 이는 포화압력이 낮아질수록 기포의 이탈직경은 증가하고 이탈 빈도는 감소하기 때문이다. 또한 LiBr 농도가 증가하면 포화온도는 증가하고 물질확산율은 감소하는데 이에 따라 기포의 성장속도가 감소하고 따라서 열전달계수가 감소하게 된다. 낮은 핀관의 열전달계수는 모든 포화압력과 농도에서 평활관의 열전달계수보다 크게 나타났다. 본 실험자료를 기반으로 상관식을 제시하였다.

쌀의 식미 관련 이화학 성분의 품종 및 작기간 변이와 상관 관계 (Varietal and Culture-Seasonal Variation in Physicochemical Properties of Rice Grain and Their Interrelationships)

  • 오용비
    • 한국작물학회지
    • /
    • 제38권1호
    • /
    • pp.72-84
    • /
    • 1993
  • 우리나라 주요 벼 장려품종들의 식미관련 이화학적 특성의 품종 및 작기간변이와 이들 특성간 상관관계를 밝히고자 1991년 작물시험장 벼 품종전시포에서 보통식 및 만직재배로 생산된 23품종 및 보통식 4개 품종과 일본에서 생산된 3개 품종에 대한 아밀로스함량 및 단백질함량을 위시하여 미식미계 검정치, 취반특성, 밥의 물성, 미분의 Viscogram 특성등을 검정한 결과를 분석 검토하였던 바 그 주요결과를 요약하면 다음과 같다. 1. 보통식에 비해 만직에서 아밀로스함량, 식미계의 맛치, 취반용출액 요-드 정색도 및 취반용출액 요-드 정색도 / 용출고형물량 비등은 유의하게 증가한 반면, 식미계의 점성치, Mg/KㆍN 치, 가열흡수률, 손실정접과 setback을 제외한 viscogram 특성치 등은 현저하게 감소하는 경향이였고 대부분의 특성에서 만식의 경우 보통식에 비해 품종간변이가 좁아지는 경향이었다. 2. 작기간 변이는 거의 무시할 정도로 작으면서 주로 품종간변이에 의해 좌우되었던 특성은 단백질함량, 밥 용적팽창률, 미분의 set back 치와 Rheolograh-Micro에 의해 측정된 모든 밥의 물리적 특성치였다. 특히 작기간변이가 컸던 특성은 아미노스함량, 식미계점성치, 가열흡수률, 취반용출액 요-드 정색도/용출고형물량 비 최고 및 최저 점도, breakdown치 등이었으며 품종$\times$작기간 교호작기용변이가 컸던 특성은 식미계의 맛치, 가열흡수률, 용출고형물량, 최종점도 및 setback치 등이었다. 3. 아밀로스함량은 조생종이 중생 내지 중만생종에 배해 낮은 편이었고 품종에 따라서 만식에 따른 함량변이정도가 달랐다. 취반용출액 요-드 정색도 / 용출고형물질 비는 일반적으로 조생종들이 작기에 따른 변화정도가 작았다. 4. 아미로스함량은 취반용출액 요-드 정색도 및 이와 용출고형물질간비와 식미계점성치는 Mg/KㆍN 치 및 맛치와 두 작기에서 모두 밀접한 상관성을 나타내었다. 또한 식미계점성치는 보통식에서 취반특성들과는 부, 손실정접과는 유의한 정상관을 나타내었으나 만식에서는 이러한 경향을 찾아 볼수 없었다. 5. 어느 작기산이든간에 취반용출액의 요-드 정색도가 높은 품종일수록 용출고형물량도 많아지는데 취반액요-드 정색도와 손실정접, 최고비도 및 breakdown치간의 필요한 상관성은 보통식에서만 유의성이 인정 되었다. 또한 취반액요-드 정색도 / 용출고형물량 비는 보통직에서 최고비도, breakdown 및 breakdown / setback치와, 만식에서 손실정접 및 동적빙성율과 고도의 부의 상관을 보였다. viscogram특성 상호간에는 두 작기에서 모두 서로 밀접한 상관성을 보였다. 6. 식미와 관련성이 높다는 이화학적 특성을 중심으로 집약분석법에 의해 공시품종들을 두 개 군으로 대별해 볼수 있었는데 한ㆍ일 양국의 양식미품종들이 서로 다른 군에 속했다.

  • PDF

Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구 (A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe)

  • 강환국;김철주;김재진
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.194-201
    • /
    • 1998
  • 전기 철도 차량의 A.C 모터 속도제어에는 여러 개의 GTO thyristor와 다이오드가 필요하다. 그런데 이러한 반도체 소자들은 약 1~2 kW의 열을 발생하기 때문에 냉각장치가 필요하며 이러한 반도체의 냉각에는 Perfluorocarbon(PFC)을 작동유체로 하는 히트파이프를 많이 사용하고 있다. 본 연구에서는 PFC 히트파이프의 증발 및 응축 열전달 계수에 미치는 관련변수로 주입율, 관의 내부 표면상태, 경사각, 증기압, 열유속 등의 영향을 파악하고, 열전달 계수를 예측할 수 있는 상관식을 제시하고자 하였다. 이를 위해 내부 표면에 그루브가 설치된 동관과 표면이 매끈한 외경 15.88mm인 동관을 이용하여 주입율이 다른 총 길이 520mm의 PFC 히트파이프와 열사이폰을 제작하고 실험을 수행하였다. 증발 열전달 계수는 열유속 15~45 kW/$m^2$의 범위일 때 2 kW/$m^2$K~5.5 kW/$m^2$K 사이의 분포를 보였다. 실험결과는 수정계수 CR=1.3을 적용할 때 Rohsenow의 핵비등 상관식과 실험치가 매우 접근된 결과를 보였으며 이러한 결과는 내부 벽면 그루브의 열전달 촉진효과이다. 응축 열전달 계수의 측정치는 1.5kW/$m^2$K~3.5kW/$m^2$K 사이의 분포를 보였으며 Nusselt 막응축 모델에 수정계수 CN=4를 도입함으로써 매우 접근된 예측이 가능하였다. 증발부 체적에 대한 작동유체 주입율은 40~100%의 범위가 적절하였다. 그리고 30$^{\circ}$이상의 경사각에서는 경사각의 영향이 미소하였다.

  • PDF